100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Heat Pump ESCO Exam Questions And Answers

Rating
-
Sold
1
Pages
11
Grade
A+
Uploaded on
05-04-2024
Written in
2023/2024

An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed defrost is based on time/temperature. The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the; - ans-Outdoor ambient thermostat The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the; - ans-Initial balance point At what temperature is an outdoor ambient thermostat normally set? - ans-Slightly above the initial balance point. The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is; - ans-The outdoor fan is inoperative. In order to determine a heat pumps' balance point, you must first calculate; - ans-The building's heat load. When a heat pump is used for heating and cooling, the system is sized by the; - ans-Cooling load. A high efficiency heat pump system designed to function from high to low ambient conditions below 10*F, may have? - ans-Two outdoor coils with each one incorporating a dual stage compressor.

Show more Read less
Institution
Esco
Module
Esco









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Esco
Module
Esco

Document information

Uploaded on
April 5, 2024
Number of pages
11
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Heat Pump ESCO Exam Questions And Answers
An air-to-air heat pump has many of the same components as an air conditioning system. The major difference is that a heat pump also has an - ans-Reversing valve
What is the difference between "demand defrost" and "timed defrost"? - ans-Demand defrost happens only when needed and timed defrost is based on time/temperature.
The thermostat that controls the auxiliary electric heat according to the outdoor temperature is called the; - ans-Outdoor ambient thermostat
The outdoor temperature at which the heat pump provides the same amount of heat as the heat loss of the conditioned space without an auxiliary heat is known as the; - ans-Initial balance point
At what temperature is an outdoor ambient thermostat normally set? - ans-Slightly above the initial balance point.
The outdoor coil is frozen solid on a "no heat" service call. The most likely reason is; - ans-The outdoor fan is inoperative.
In order to determine a heat pumps' balance point, you must first calculate; - ans-The building's heat load.
When a heat pump is used for heating and cooling, the system is sized by the; - ans-Cooling load. A high efficiency heat pump system designed to function from high to low ambient conditions below 10*F, may have? - ans-Two outdoor coils with each one incorporating a dual stage compressor.
Room thermostats for heat pumps should be installed; - ans-As near to the main return air grill as possible.
When the heat pump compressor has malfunctioned, the customer has the option to switch the system into; - ans-Emergency heat mode.
Start up with a night set back digital thermostat requires the technician to always; - ans-Teach the customer how to program the thermostat.
The heat pump defrost board can be manipulated by the technician to; - ans-Simulate the defrost cycle.
The air-to-air heat pump outdoor unit is most efficient if located; - ans-In a moderate climate zone.
Which of the following are innovations that may be found on new high efficiency units? - ans-ECM fan motors.
How may a lockout (impedance) relay be reset? - ans-Simply disconnect power to the unit momentarily.
The temperature difference between the 1st and 2nd bulbs for heating on a heat pump thermostat is; - ans-Approximately 2*F
SEER is calculated by; - ans-Dividing the Btu's removed by the watts consumed during the cooling season.
£8.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Prose1 Strayer University
Follow You need to be logged in order to follow users or courses
Sold
609
Member since
1 year
Number of followers
71
Documents
6462
Last sold
1 day ago
REALITIEXAM

I know how frustrating it can get with all those assignments mate. Nursing Being my main profession line, i have essential guides that are A graded, I am a very friendly person so don

4.5

297 reviews

5
227
4
24
3
20
2
8
1
18

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions