Oil Heat 1 NORA Silver Exam Questions & Answers 100% Verified
Ch 1 Flame Retention Burner - ANSWER-An oil burner, designed to hold the flame near the nozzle surface. Strongly swirling air pattern recirculates combustion products for more complete mixing of fuel and air. 
 
Ch 1 Motor - ANSWER-Electric motor drives the fan and fuel pump. In the event of motor failure, be sure to replace with motor of same rotation, frame size and RPM 
 
Ch 1 Multiblade Fan + Air Shutter - ANSWER-A fan wheel within the burner housing that is driven directly by the motor shaf...
- Exam (elaborations)
- • 2 pages •
Ch 1 Flame Retention Burner - ANSWER-An oil burner, designed to hold the flame near the nozzle surface. Strongly swirling air pattern recirculates combustion products for more complete mixing of fuel and air. 
 
Ch 1 Motor - ANSWER-Electric motor drives the fan and fuel pump. In the event of motor failure, be sure to replace with motor of same rotation, frame size and RPM 
 
Ch 1 Multiblade Fan + Air Shutter - ANSWER-A fan wheel within the burner housing that is driven directly by the motor shaf...
Oil Burner Vocab Exam Questions and Answers 100% Verified
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER-on the side of the oil pump - used to remove air from oil line 
 
cad cell - ANSWER-detects if a flame is present 
 
combustion head - ANSWER-plate at the end of the burners air tube - specifically designed slots to guide air flow for ideal combustion 
 
drawer assembly - ANSWER-...
- Exam (elaborations)
- • 2 pages •
air bend - ANSWER-regulates the volume (amount) by changing it to a spray of tiny droplets 
 
atomizing - ANSWER-vaporizing liquid oil (turning it into gas) by changing it to a spray of tiny droplets 
 
bleeder - ANSWER-on the side of the oil pump - used to remove air from oil line 
 
cad cell - ANSWER-detects if a flame is present 
 
combustion head - ANSWER-plate at the end of the burners air tube - specifically designed slots to guide air flow for ideal combustion 
 
drawer assembly - ANSWER-...
Unit 32 - Oil Heat Exam Questions & Answers (RATED +)
When nozzles problems are apparent, the nozzle should be removed using ____ and replaced - ANSWER-a special nozzle wrench 
 
The cad cell relay is a safety device that uses which of the following to prove ignition? - ANSWER-light in the combustion chamber 
 
The stack switch or stack relay _____. - ANSWER-shuts down the burner if it does not sense heat in the stack 
 
A condensing oil furnace operates at a higher 
efficiency because part of the heat output is ____. - ANSWER-latent heat 
 
Impro...
- Exam (elaborations)
- • 4 pages •
When nozzles problems are apparent, the nozzle should be removed using ____ and replaced - ANSWER-a special nozzle wrench 
 
The cad cell relay is a safety device that uses which of the following to prove ignition? - ANSWER-light in the combustion chamber 
 
The stack switch or stack relay _____. - ANSWER-shuts down the burner if it does not sense heat in the stack 
 
A condensing oil furnace operates at a higher 
efficiency because part of the heat output is ____. - ANSWER-latent heat 
 
Impro...
Chapter 42- Oil Fired Heating Systems Exam With Complete Verified Solutions!!Chapter 42- Oil Fired Heating Systems Exam With Complete Verified Solutions!!
the breaking up of a liquid into tiny droplets - ANSWER-atomization 
 
the ignition of a large amount of vaporized fuel oil that blows soot backward out of the combustion chamber - ANSWER-blowback 
 
a pump used to move fuel oil from the main storage tank to a fuel oil accumulator or reservoir tank nearer to the oil burner - ANSWER-booster pump 
 
a small plug that is threaded into the internal bypass between a fuel unit's inlet and return ports - ANSWER-bypass plug 
 
a light-sensitive semicon...
- Exam (elaborations)
- • 5 pages •
the breaking up of a liquid into tiny droplets - ANSWER-atomization 
 
the ignition of a large amount of vaporized fuel oil that blows soot backward out of the combustion chamber - ANSWER-blowback 
 
a pump used to move fuel oil from the main storage tank to a fuel oil accumulator or reservoir tank nearer to the oil burner - ANSWER-booster pump 
 
a small plug that is threaded into the internal bypass between a fuel unit's inlet and return ports - ANSWER-bypass plug 
 
a light-sensitive semicon...
Oil Fired Heating Systems Exam Questions and Answers 100% Pass
Pour point - ANSWER-The maximum temperature at which oil can be stored, retrieved and used 
 
Complete Combustion flames - ANSWER-mainly yellow 
 
Incomplete combustion flame - ANSWER-dull reddish orange 
 
The Range of CO2 content indicating proper combustion in an oil fired furnace - ANSWER-8% to 12% 
 
For accurate readings for a CO2 test, the analyzer probe should be placed - ANSWER-near the hottest part of the flue 
 
The most common reason an oil-fired furnace is over firing - ANSWER-origi...
- Exam (elaborations)
- • 5 pages •
Pour point - ANSWER-The maximum temperature at which oil can be stored, retrieved and used 
 
Complete Combustion flames - ANSWER-mainly yellow 
 
Incomplete combustion flame - ANSWER-dull reddish orange 
 
The Range of CO2 content indicating proper combustion in an oil fired furnace - ANSWER-8% to 12% 
 
For accurate readings for a CO2 test, the analyzer probe should be placed - ANSWER-near the hottest part of the flue 
 
The most common reason an oil-fired furnace is over firing - ANSWER-origi...
Oil burner's test questions 1-200 Exam Questions andAnswers 100% Accurate
When applying current through a conductor that is wound in coil, the magnetic lines of force created are used in - ANSWER-•Solenoid valve 
. Relay 
.Electric Motor 
 
If in an average 15-amp residential heating circuit, the fuse occasionally blows, you should - ANSWER-Install a 15-amp breaker 
 
To determine the "electrical potential" available at any given point in a circuit you should use a: - ANSWER-Voltmeter 
 
Oil burner ignition systems normally operate at what primary voltage - ANSWER...
- Exam (elaborations)
- • 20 pages •
When applying current through a conductor that is wound in coil, the magnetic lines of force created are used in - ANSWER-•Solenoid valve 
. Relay 
.Electric Motor 
 
If in an average 15-amp residential heating circuit, the fuse occasionally blows, you should - ANSWER-Install a 15-amp breaker 
 
To determine the "electrical potential" available at any given point in a circuit you should use a: - ANSWER-Voltmeter 
 
Oil burner ignition systems normally operate at what primary voltage - ANSWER...
Hvac 108 Exam Questions With 100% Correct Answers
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oil burner​ nozzle, always use​ a(n)_____. - ANSWER-nozzle wrench 
 
When doing a smoke spot test on a heavy​ boiler, an acceptable smoke spot number​ is_____. - ANSWER-two 
 
When reviewing the results of a combustion efficiency test for a furnace with a flame retention​ burner, the oxygen level should be​ _____. - ANSWER-3 to 5 percent 
 
In the presen...
- Exam (elaborations)
- • 1 pages •
The primary control starts burner operation in response to a signal from​ the_____. - ANSWER-room thermostat 
 
When replacing an oil burner​ nozzle, always use​ a(n)_____. - ANSWER-nozzle wrench 
 
When doing a smoke spot test on a heavy​ boiler, an acceptable smoke spot number​ is_____. - ANSWER-two 
 
When reviewing the results of a combustion efficiency test for a furnace with a flame retention​ burner, the oxygen level should be​ _____. - ANSWER-3 to 5 percent 
 
In the presen...
Oil Burner License Exam Questions & Answers A+ Pass
Add an oil line heater. 
 
Cut with #1 fuel or kerosene. 
 
What is the maximum tank size allowed inside unenclosed? - ANSWER-660 gal 
 
What is the purpose of a delayed oil valve? - ANSWER-Allows time for the oil pump to get up to speed. 
 
Delays oil flow to the nozzle. 
 
On a call where a hydronic heat system is putting out too much heat, the issue could be? - ANSWER-A shorted out thermostat. 
 
When measuring a cad cell with the burner running and the ff terminals jumped out, what should ...
- Exam (elaborations)
- • 26 pages •
Add an oil line heater. 
 
Cut with #1 fuel or kerosene. 
 
What is the maximum tank size allowed inside unenclosed? - ANSWER-660 gal 
 
What is the purpose of a delayed oil valve? - ANSWER-Allows time for the oil pump to get up to speed. 
 
Delays oil flow to the nozzle. 
 
On a call where a hydronic heat system is putting out too much heat, the issue could be? - ANSWER-A shorted out thermostat. 
 
When measuring a cad cell with the burner running and the ff terminals jumped out, what should ...
Oil Electric Final Exam Questions and Answers(GRADED A+)
To wire an oil burner in MA you must be a licensed electrician: T or F - ANSWER-False 
 
Flash Point is the lowest temp. at which the vapours above the fuel will ignite: T or F - ANSWER-True 
 
Pour Point is the lowest temperature at which No. 2 fuel oil can be lit: T or F - ANSWER-False 
 
If the centrifugal switch on a split phase motor did not open the motor could burn out: T or F - ANSWER-True 
 
In MA 527CMR4.00 a 15 amp breaker, emergency switch, thermal switch, service switch, are require...
- Exam (elaborations)
- • 4 pages •
To wire an oil burner in MA you must be a licensed electrician: T or F - ANSWER-False 
 
Flash Point is the lowest temp. at which the vapours above the fuel will ignite: T or F - ANSWER-True 
 
Pour Point is the lowest temperature at which No. 2 fuel oil can be lit: T or F - ANSWER-False 
 
If the centrifugal switch on a split phase motor did not open the motor could burn out: T or F - ANSWER-True 
 
In MA 527CMR4.00 a 15 amp breaker, emergency switch, thermal switch, service switch, are require...
HVAC Residential Oil Burners Chpt. 1-8 Exam Questions and Answers(SCORED A+)
wax crystals form, gels up and the viscosity of the oil goes up - ANSWER-What happens to fuel oil when it is stored outside on a day when the temp. is only 12 degrees F? 
 
85% carbon, 15% nitrogen, (ASTM D-396) - ANSWER-What is the chemical composition of fuel oil? 
 
If flames hit chamber it will cause soot and carbon, blocks up the heat exchanger passage - ANSWER-What does impingement mean and why is it a problem? 
 
1 quarter inch - ANSWER-How far is the burner blast tube set back in a combu...
- Exam (elaborations)
- • 4 pages •
wax crystals form, gels up and the viscosity of the oil goes up - ANSWER-What happens to fuel oil when it is stored outside on a day when the temp. is only 12 degrees F? 
 
85% carbon, 15% nitrogen, (ASTM D-396) - ANSWER-What is the chemical composition of fuel oil? 
 
If flames hit chamber it will cause soot and carbon, blocks up the heat exchanger passage - ANSWER-What does impingement mean and why is it a problem? 
 
1 quarter inch - ANSWER-How far is the burner blast tube set back in a combu...