Backflow Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Backflow? On this page you'll find 42 study documents about Backflow.
Page 2 out of 42 results
Sort by
![BACKFLOW TESTER EXAM](/docpics/5261772/663eaf64be37a_5261772_121_171.jpeg)
-
BACKFLOW TESTER EXAM
- Exam (elaborations) • 14 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
A double check valve assembly is installed 12 above the floor for? - Answer-Maintenance 
 
A low hazard Backflow preventer is a? - Answer-Double Check valve assembly 
 
A field test report for a double check will include the manufacturer name, model, size and ?? - Answer-Serial number 
 
Double check valve assembly components are?? - Answer-Independently acting 
 
A double check valve assembly hydraulic use is?? - Answer-Continuous 
 
A detector assembly contains a device of equal? - Answer-Prot...
![BACKFLOW PREVENTION DEVICES "TROUBLESHOOTING QUESTIONS"](/docpics/5261758/663eaeefa58aa_5261758_121_171.jpeg)
-
BACKFLOW PREVENTION DEVICES "TROUBLESHOOTING QUESTIONS"
- Exam (elaborations) • 4 pages • 2024
- Available in package deal
-
- $10.49
- + learn more
When testing that air inlet in a pressure vacuum breaker, the bleed valve assembly for shut off valve leakage is installed on: - Answer-(B) The number 1test cock. 
 
When testing the air inlet and a pressure vacuum breaker, if the high side believe needle valve must be open more than a quarter turn, to indicates: - Answer-(C) A leaking number 1 shut off valve. 
 
When testing the air inlet and in a pressure vacuum breaker, if the high side bleed needle valve is open 1/4 turn and gage drops to ze...
![BACKFLOW EXAM QUESTION AND ANSWERS](/docpics/5261742/663eae38d7cff_5261742_121_171.jpeg)
-
BACKFLOW EXAM QUESTION AND ANSWERS
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
Double Check Valve Assembly - Answer-A testable mechanical device consisting of two independently operating, spring-loaded check valves, four test cocks, and two full port shut off valves 
 
the purpose of an ASSE 1018 trap primer is to - Answer-maintain a trap seal 
 
a laboratory faucet vacuum breaker must contain - Answer-two independently acting check valves 
 
ASSE 1060 - Answer-outdoor enclosures standard, freeze protective enclosures must provide protection to a remedies of -30 f 
 
devic...
![BACKFLOW PRACTICE EXAM](/docpics/5261725/663ead8472d64_5261725_121_171.jpeg)
-
BACKFLOW PRACTICE EXAM
- Exam (elaborations) • 7 pages • 2024
- Available in package deal
-
- $12.49
- + learn more
1) Backflow is the undesirable reversal of flow of water or other substances through a cross connection into the public water system or consumer's: - Answer-C. Public water system or consumer's portable water system 
 
2) An approved airgap (AG) is a physical separation between the free-flowing end of a: - Answer-D. Potable water supply pipe line in the overflow rim of an open or non-pressurized receiving vessel 
 
3) And indirect cross-connection is one that is subject to what type of backflo...
![SAMPLE EXAM QUESTIONS AND RECOMMENDED REFERENCES FOR ABC'S BACKFLOW PREVENTION ASSEMBLY TEST OR EXAM](/docpics/5261706/663eacd16223c_5261706_121_171.jpeg)
-
SAMPLE EXAM QUESTIONS AND RECOMMENDED REFERENCES FOR ABC'S BACKFLOW PREVENTION ASSEMBLY TEST OR EXAM
- Exam (elaborations) • 2 pages • 2024
- Available in package deal
-
- $8.49
- + learn more
What is the pressure at the base of a 100 foot high standpipe filled with water? - Answer-43.3 psi 
 
A column of water exerts pressure at the bottom of a column due to - Answer-Weight of the water 
 
What is the primary consideration when deciding whether to install a reduced pressure or a double valve assembly? - Answer-Degree of hazard 
 
A cross-connection is an actual or potential connection that could allow backflow to occur between a potable water system and a piping system that contains ...
![BACKFLOW TROUBLESHOOTING QUIZ](/docpics/5261681/663eac1cae90b_5261681_121_171.jpeg)
-
BACKFLOW TROUBLESHOOTING QUIZ
- Exam (elaborations) • 3 pages • 2024
- Available in package deal
-
- $10.19
- + learn more
While field testing the check valve of a pressure vacuum breaker, water continues to flow from the # 2 test cock . How do you proceed ? - Answer-Open the bleed off valve until the flow slows to a slight drip. 
 
Well field testing the first check valve of a double check valve assembly, water continues to flow from the site tube. How do you proceed? - Answer-Observe reading on gauge (first step). Open high side of bleed valve (second step). 
 
While field testing the check valve of a spill resist...
![Backflow exam review questions and rationale answers 2024](/docpics/5241729/663c9af882a20_5241729_121_171.jpeg)
-
Backflow exam review questions and rationale answers 2024
- Exam (elaborations) • 21 pages • 2024
- Available in package deal
-
- $9.49
- + learn more
Backflow exam review questions and rationale answers 2024
![BACKFLOW TEST EXAM 2024 WITH 100% CORRECT ANSWERS](/docpics/5118840/662c34884d69c_5118840_121_171.jpeg)
-
BACKFLOW TEST EXAM 2024 WITH 100% CORRECT ANSWERS
- Exam (elaborations) • 6 pages • 2024
-
- $15.49
- + learn more
BACKFLOW TEST EXAM 2024 WITH 100% CORRECT ANSWERS 
 
 
If an RPBA contiunually drips or drains under full flow conditions - correct answer The #2 check valve is fouled 
 
When a residential property has a backflow-prevention device/assembly installed on the service line the best means to control thermal expansion is with a - correct answer Thermal expansion tank 
 
According to the Nebraska regulations what is the minimum acceptable air gap for a 2" pipe located 1" from the wall - correct answ...
![BACKFLOW PRACTICE EXAM 2024](/docpics/5118822/662c32e5594f4_5118822_121_171.jpeg)
-
BACKFLOW PRACTICE EXAM 2024
- Exam (elaborations) • 9 pages • 2024
-
- $16.49
- + learn more
BACKFLOW PRACTICE EXAM 2024 
 
 
1) Backflow is the undesirable reversal of flow of water or other substances through a cross connection into the public water system or consumer's: - correct answer C. Public water system or consumer's portable water system 
 
2) An approved airgap (AG) is a physical separation between the free-flowing end of a: - correct answer D. Potable water supply pipe line in the overflow rim of an open or non-pressurized receiving vessel 
 
3) And indirect cross-connecti...
![BACKFLOW EXAM STUDY GUIDE](/docpics/5032888/662031e141ad6_5032888_121_171.jpeg)
-
BACKFLOW EXAM STUDY GUIDE
- Other • 5 pages • 2024
- Available in package deal
-
- $11.49
- + learn more
BACKFLOW EXAM STUDY GUIDE
![Verkoop je kennis op stuvia](https://www.stuvia.com/hosted-imgs/app/stock-fotos/banner_seller_big.jpg)
Did you know that on average a seller on Stuvia earns $82 per month selling study resources? Hmm, hint, hint. Discover all about earning on Stuvia