ACCURATE AND VERIFIED ACTUAL EXAM
QUESTIONS WITH DETAILED ANSWERS FOR
GUARANTEED PASS | ALREADY GRADED A
1. With the rising cost of refrigerant, the value of the refrigerant stored in a 50-lb. recovery
tank is worth how many times the cost of the recovery tank?
A. Equal to the tank
B. 2x the tank cost
C. 5x the tank cost ✅
D. 10x the tank cost
Rationale: The refrigerant inside a recovery tank is often more valuable than the tank itself—up
to 5 times its cost due to rising refrigerant prices.
2. R-134a is a corrosive refrigerant:
A. True
B. False ✅
Rationale: R-134a is non-corrosive and widely used in automotive A/C systems.
3. Used cylinders can be recycled with other scrap metal:
A. True ✅
B. False
Rationale: If emptied and properly depressurized, used cylinders may be recycled like other
scrap metal.
4. Refrigeration cylinders must be re-tested at what intervals?
A. Every 3 years
B. Every 7 years
C. Every 10 years
D. Every 5 years ✅
Rationale: DOT regulations require re-testing of refrigerant cylinders every five years to ensure
safety.
5. Persons servicing MVACs must be certified as what if performing the service for
compensation?
A. Section 608 technicians
,B. HVAC contractors
C. Universal technicians
D. Section 609 MVAC technicians ✅
Rationale: Section 609 certification is mandatory for servicing MVAC systems for compensation.
6. Ozone in the stratosphere is created when UV light strikes which molecules?
A. Nitrogen
B. Water vapor
C. Oxygen ✅
D. Carbon dioxide
Rationale: Ozone (O₃) forms when UV light splits O₂ molecules, allowing single atoms to bond
with other O₂ molecules.
7. The AHRI standard now limits unsaturated impurities in HFC-134a to what maximum level?
A. 25 PPM
B. 35 PPM
C. 50 PPM
D. 40 PPM ✅
Rationale: AHRI mandates no more than 40 parts per million of unsaturated impurities in HFC-
134a.
8. Refrigerants may be mixed in recovery cylinders:
A. True
B. False ✅
Rationale: EPA regulations prohibit mixing refrigerants during recovery to avoid contamination
and disposal issues.
9. After reaching the required recovery vacuum, if system pressure rises, what might that
indicate?
A. System is clean
B. Leak, liquid refrigerant, or oil-trapped gas ✅
C. Pressure gauge failure
D. Vacuum pump efficiency
Rationale: A pressure rise may indicate trapped refrigerant or a system leak.
10. Most halogenated compounds will decompose at room temperature:
A. True
B. False ✅
, Rationale: Halogenated compounds like CFCs are stable and do not decompose at room
temperature.
11. HFC-152a MVAC systems must be designed to avoid cabin concentrations above what level
for over 15 seconds?
A. 2.5%
B. 3.7% ✅
C. 4.2%
D. 5.5%
Rationale: Exposure limits for flammable refrigerants like HFC-152a are strictly regulated to
3.7% max.
12. Empty refillable refrigerant tanks must be evacuated to a vacuum of:
A. 20 inches of Hg
B. 25 inches of Hg
C. 27 inches of Hg ✅
D. 29 inches of Hg
Rationale: To prevent atmospheric contamination, tanks must be evacuated to at least 27
inches of mercury.
13. The pressure in a refrigerant cylinder with one ounce of liquid refrigerant is:
A. Half that of a full cylinder
B. Higher
C. Lower
D. Exactly the same as a full cylinder ✅
Rationale: Vapor pressure depends on temperature, not the amount of liquid refrigerant
present.
14. EPA requires a leak to be repaired prior to recharging an MVAC system:
A. True
B. False ✅
Rationale: Unlike stationary systems, EPA does not require leak repair before recharging MVAC
systems.
15. A refillable refrigerant cylinder must not be filled above what percent of its capacity?
A. 70%
B. 80% ✅
C. 85%