100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ACI Written Exam Questions & Answers

Puntuación
-
Vendido
-
Páginas
14
Grado
A+
Subido en
06-04-2025
Escrito en
2024/2025

ACI Written Exam Questions & Answers The sensor of the temperature measureing device shall be submerged a minimum of ____ in - ANSWERS3 (75mm) The temperature measureing device shall have a capacity of measuring temperature of freshly mixed conrcrete to +-_____ degrees F throught a range of _____ - ANSWERS1(.5 degrees C), 30-120 (0-50 degrees C) The temperature measuring device shall be calibrated____, or whenever there is a question of _____ - ANSWERSannually, accuracy The temp of concrete may be measured in a wheelbarrow - ANSWERStrue the temp of concrete may be measured in a wall form - ANSWERStrue A composite sample of concrete is required even if the only purpose for obtaining the sample is to determine temp. - ANSWERSfalse What must be done to the sample container prior to sampling the concrete - ANSWERSdampen (with water) what must be done to the concrete surrounding the temp measuring device after the device has submerged - ANSWERSPress concrete around measuring device How long must the temp device remain in the concrete - ANSWERSat least 2 minutes (but no more than 5)

Mostrar más Leer menos
Institución
ACI Written
Grado
ACI Written









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ACI Written
Grado
ACI Written

Información del documento

Subido en
6 de abril de 2025
Número de páginas
14
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ACI Written Exam Questions & Answers

The sensor of the temperature measureing device shall be submerged a minimum of ____ in -
ANSWERS3 (75mm)



The temperature measureing device shall have a capacity of measuring temperature of freshly
mixed conrcrete to +-_____ degrees F throught a range of _____ - ANSWERS1(.5 degrees C), 30-
120 (0-50 degrees C)



The temperature measuring device shall be calibrated____, or whenever there is a question of
_____ - ANSWERSannually, accuracy



The temp of concrete may be measured in a wheelbarrow - ANSWERStrue



the temp of concrete may be measured in a wall form - ANSWERStrue



A composite sample of concrete is required even if the only purpose for obtaining the sample is
to determine temp. - ANSWERSfalse



What must be done to the sample container prior to sampling the concrete - ANSWERSdampen
(with water)



what must be done to the concrete surrounding the temp measuring device after the device has
submerged - ANSWERSPress concrete around measuring device



How long must the temp device remain in the concrete - ANSWERSat least 2 minutes (but no
more than 5)

, After temp of concrete is read, what then is required - ANSWERSreporting of temp



the temp of concrete to be measured to the nearest ____degree F - ANSWERS1 (.5 degree C)



According to the ASTM C1064 what is one reason to take the temp of concrete - ANSWERSverify
conformance to a specified requirement for temp



A max temp of concrete is specified in ASTM C1064 - ANSWERSFalse



The sample of concrete used for temp determination must be rodded 25 times - ANSWERSFalse



Sampling by this method is required when tests are to be made to determine ____ with
specification requirements - ANSWERScompliance



The method covers sampling from four types of mixers which are _____, _____, ____, and
_______ - ANSWERSstationary mixes, paving mixers, revolving drum mixers and open top mixers



The maximum allowable time between obtaining the first and final portions of a composite
sample is ______ minutes - ANSWERS15



Portions of a composite sample shall be thoroughly remixed before beginning tests on the
sample - ANSWERSTrue



The maximum elapsed time allowed between obtaining the final portion of the composite
sample and beginning the tests for slump, temp, and air content is ______ minutes - ANSWERS5



the molding of strength test specimens shall begin within ____ minutes after fabricating the
composite sample - ANSWERS15
$8.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Thumbnail
Package deal
BUNDLE - ACI EXAMS
-
12 2025
$ 102.88 Más información

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Bensuda Oxford University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
846
Miembro desde
3 año
Número de seguidores
445
Documentos
21389
Última venta
17 horas hace
ECONOMICS,NURSING,BIOLOGY AND ALL REVISION MATERIALS

DEDICATED TO PROVIDE YOU WITH THE BEST LEARNING MATERIALS THAT WILL IMPROVE YOUR GRADES ,WELCOME TO ALIZGRADES AND LETS DO IT TOGETHER!!! GOODLUCK!!!!!!!

3.7

158 reseñas

5
74
4
24
3
25
2
11
1
24

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes