NCIDQ exam questions with correct answers 2023 updated to pass
NCIDQ exam questions with correct answers 2023 updated to pass egress - correct answer way out, exit accessible route - correct answer is a continuous unobstructed path connecting all accessible elements and spaces in a building or facility width of corridor should be > than or = to 44" common pathway - correct answer The point where you can decide to take one or more exits or a separate access to 2 exits travel distance - correct answer Most remote point in occupied portions of a building to the exit Max Travel distance limit - correct answer Sprinkler - 250 ' Non sprinkler 250' Measures along path of travel —- what type of occupancy is it though? Exit Discharge - correct answer Path from an exit to a public area like a street Exit Access - correct answer Path from any space of a building to an exit Exits - correct answer Doors to the outside using exit stairs or horizontal exits ASTM E 162 - correct answer Surface flammability of materials using a radiant heat energy source. Contains the radiant heat panel, and the thermopile ASTM E84 Steiner tunnel chamber test - correct answer A 10 minute test Vertical flame test ASTM D 6413 - correct answer 12 second test Measures the after flame & char length BOMA - correct answer One system of measuring space, measures from center line of demising partition , or from inside face of glass , if glass is more than 50% of wall area .....Columns do not count ! Rentable Area (net area ) - correct answer Comes up during programming, a furniture arrangement based on specific pieces typically used in company standards of sq ft efficiency factor - correct answer Amount of actual usable space versus non-usable space, like columns, partitions or circulation, used for preliminary estimating of occupant area net / total. Actual area used by the tenant multiplied by the load factor Load Factor - correct answer Account for shared common areas, excludes major vertical penetrations like stairwells or elevators BOMA or IFMA - correct answer used by building owner to Charge each tenant for public areas, restrooms, amenities like a gym, lobby or atrium Accounted for in a load factor Rentable area (sq ft)formulas All rental area is charged by the building owner to you even it's not used by you - correct answer RA = OA /load factor like 2000/ 1120 RA / Load factor = OA
Written for
- Institution
- NCIDQ
- Course
- NCIDQ
Document information
- Uploaded on
- May 13, 2023
- Number of pages
- 30
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
- egress way out
- exit
-
ncidq exam questions with correct answers 2023 updated to pass
-
accessible route is a continuous unobstructed path connecting all accessible elements and spaces in a building or fa
Also available in package deal