- Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about ? On this page you'll find 200 study documents about .
200 results
Exam (elaborations)
Computed tomography Questions and Correct Answers/ Latest Update / Already Graded
CT basics 
Ans: • Essentially an x-ray tube that rotates round the pt 
• Table moves, feeding pt into the gantry 
• Each large is data collected as a series of slices 
o Each slice is divided into voxels (volume elements) 
 
Multislice scanner 
Ans: voxel thickness is equal to x-ray beam thickness 
 
Slices 
2 | Page 
 
Ans: o Thinner slice higher radiation dose better quality image 
o Width and height depend on FOV 
o Determined by the operator 
o Thickness is determi...
Exam (elaborations)
Computed Tomography Questions and Correct Answers/ Latest Update / Already Graded
The word Tomo is tomography means 
Ans: To cut 
 
What is the Z-axis 
Ans: the thickness of a cross-sectional slice. 
 
The degree to which an x-ray beam is reduced by an object is 
referred to as 
Ans: Attenuation 
 
The amount of the x-ray beam that is absorbed per unit thickness of 
the absorber 
Ans: Linear Attenuation 
 
2 | Page 
 
difference in linear attenuation coefficient is responsible for 
Ans: Image Contrast 
 
These are the two dimensional squares of th...
Exam (elaborations)
Computed Tomography Questions and Correct Answers/ Latest Update / Already Graded
For a typical 64 to 128 detector array CT scanner, the fan angle is 
approximately ___ degrees, while the full cone angle is about ___ 
degrees 
Ans: 60, 2.4 
 
CT Fan beam projection diagram 
Ans: 
 
CT Cone beam projection diagram 
Ans: 
 
CT True cone beam projection diagram 
Ans: 
 
2 | Page 
 
Why is an arc-shaped detector beneficial in CT? 
Ans: By mounting the detector modules on a support structure that is 
aligned along the radius of curvature emanating fr...
Exam (elaborations)
Computed Tomography Questions and Correct Answers/ Latest Update / Already Graded
CT was developed in 
Ans: 1970s 
 
Pioneer of CT and also Nobel Prize winner? 
Ans: Godfrey Hounsfield 
 
A collimated x-ray beam is directed on the patient and it detected 
by a 
Ans: Solid state image receptor 
 
3 possible Types of image planes shown on the CT monitors? 
Ans: Transverse, Sagittal, Coronal 
 
Conventional Tomography is also called? and why? 
2 | Page 
 
Ans: Axial Tomography: the plane of the image is parallel with the long 
axis of the body 
 
Typ...
Exam (elaborations)
Computed Tomography Questions and Correct Answers/ Latest Update / Already Graded
Godfrey Hounsfield in 1970 
Ans: Who invented CT and when 
 
1st generation scanner 
Ans: Pencil beam 
Single Detector 
Translates 1 degree 
Took 5 minutes to get data for one slice 
 
Slow 
Ans: Disadvantage of 1st generation scanner 
 
2nd generation scanner 
2 | Page 
 
Ans: Fan shaped be
Exam (elaborations)
Computed Tomography Questions and Correct Answers/ Latest Update / Already Graded
Each sweep of the source-detector around the body during CT is 
called a _____. 
Ans: translation 
 
Each CT projection records variations in ____. 
Ans: mass density and effective atomic number 
 
Each CT projection is ____. 
1. printed on film 
2. stored on the computer 
3. displayed on the monitor 
Ans: stored on the computer 
 
2 | Page 
 
The cross-sectional anatomy is translated into ____ during CT 
reconstruction. 
Ans: a matrix of values
Exam (elaborations)
Computed tomography (CT) Board Review - Body CT: The Essentials
Computed tomography (CT) Board Review - Body CT: The Essentials
Package deal
Computed Tomography (CT) Bundled Exams Questions and Answers Multiple Versions Latest Updates (2024/2025) (Complete and Accurate)
Computed Tomography (CT) Bundled Exams Questions and Answers Multiple Versions Latest Updates (2024/2025) (Complete and Accurate)
Exam (elaborations)
Computed Tomography (CT) Questions and Answers Latest Update Already Passed
Computed Tomography (CT) Questions 
and Answers Latest Update Already 
 
Passed 
 
Which artifact is caused by high-density contrast material? 
Beam hardening artifact 
 
Which protocol is best for imaging the pancreas? 
Pancreatic protocol with arterial and venous phases 
 
Which CT scan is used to evaluate suspected appendicitis? 
CT Abdomen and Pelvis with contrast 
 
Which imaging technique is used to visualize joint structures? 
CT Arthrography 
 
Which parameter influences the number of sl...
Exam (elaborations)
Computed Tomography Exam Questions and Answers Latest Update 2025 Already Passed
Computed Tomography Exam Questions and Answers Latest Update 2025 Already Passed 
what term is applied to a single square, or picture element, in the image display matrix - Answers pixel 
what determines the amount of data displayed on the monitor - Answers field of view 
a volume element is called - Answers voxel 
a relative comparison of x-ray attenuation of a voxel of tissue to an equal volume of water - Answers CT number 
what is the CT number of water - Answers 0 
the major system componen...
Exam (elaborations)
COMPUTED TOMOGRAPHY- EXAM QUESTIONS AND CORRECT ANSWERS (GRADED A+)
COMPUTED TOMOGRAPHY- EXAM QUESTIONS AND CORRECT ANSWERS (GRADED A+) 
THE ABILITY TO SCAN MOVING OBJECTS EFFECTIVELY IS - Answers TEMPORAL RESOLUTION 
WHEN A CT IMAGE APPEARS GRAINY OR SPECKLED IT IS REFERRED TO AS A - Answers NOISY IMAGE 
HOW IS NOISE REDUCED - Answers BY INCREASING 
1. mAs 2. slice thickness 3. pixel size 
IF MORE PHOTONS ARE DETECTED THE NOISE IS - Answers LESS APPARENT 
WHAT IS CREATED WHEN THE HOUNSFIELD NUMBERS ARE NOT ACCURATE FOR CONSISTENT MATERIAL BECAUSE OF BEAM DIVER...
Exam (elaborations)
COMPUTED TOMOGRAPHY EXAM QUESTIONS AND CORRECT ANSWERS LATEST UPDATE 2024-2025 (RATED A+)
COMPUTED TOMOGRAPHY EXAM QUESTIONS AND CORRECT ANSWERS LATEST UPDATE (RATED A+) 
What are the Fundamental Principle of CT ? - Answers Image of an object is reconstructed on the basis of the attenuation that occurs as x-radiation is transmitted through it. 
What are the Fundamental Principle of CT ? (Data Acquisition) - Answers X-ray beam is rotated around the patient, exposing a given volume of tissue form all direction. Detector measures radiation as it transmitted through PT. 
What are the Fu...
Exam (elaborations)
Bushong ch 28-3 worksheet_ Computed Tomography Exam Questions And Answers Latest Update
Bushong ch 28-3 worksheet_ Computed Tomography Exam Questions And Answers Latest Update
Exam (elaborations)
Computed Tomography Exam Review (Mosby's Third Edition) – Procedures Exam Questions And Answers Latest Update 2025
Computed Tomography Exam Review (Mosby's Third Edition) – Procedures Exam Questions And Answers Latest Update 2025
Exam (elaborations)
Computed tomography (CT) Board Review - Body CT: The Essentials
Computed tomography (CT) Board Review - Body CT: The Essentials 
Computed tomography (CT) is at the heart of every modern radiology department because of its: 
1. speed 
2. reliability 
3. ability to separate overlapping structures - ANS: 1, 2, & 3 
 
The primary interaction with the anode is excitation resulting in ___ radiation. - ANS: Infrared (heat) 
 
X-rays pass through the patient interacting with tissue by absorption or scattering, which results in a measured attenuation of the incident ...
Exam (elaborations)
COMPUTED TOMOGRAPHY CHAPTER 1 LATEST UPDATE 2024/2025
COMPUTED TOMOGRAPHY CHAPTER 1 
LATEST UPDATE 2024/2025
Exam (elaborations)
Computed Tomography Exam Prep Questions and Answers (Latest Update 2025)
Computed Tomography Exam Prep Questions and Answers (Latest Update 2025)
Exam (elaborations)
Computed Tomography Exam Questions and Answers (Latest Update 2025)
Computed Tomography Exam Questions and Answers (Latest Update 2025)
Exam (elaborations)
Computed Tomography Test Prep Questions and Answers (Latest Update 2025)
Computed Tomography Test Prep Questions and Answers (Latest Update 2025)
Exam (elaborations)
Computed Tomography (CT) Exam Questions and Answers (Latest Update 2025)
Computed Tomography (CT) Exam Questions and Answers (Latest Update 2025)