100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

HVAC JOURNEYMAN EXAM QUESTIONS WITH 100% COMPLETE SOLUTIONS | LATEST UPDATE

Rating
-
Sold
-
Pages
17
Grade
A+
Uploaded on
19-12-2025
Written in
2025/2026

HVAC JOURNEYMAN EXAM QUESTIONS WITH 100% COMPLETE SOLUTIONS | LATEST UPDATE

Institution
HVAC
Course
HVAC










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
HVAC
Course
HVAC

Document information

Uploaded on
December 19, 2025
Number of pages
17
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

HVAC JOURNEYMAN EXAM QUESTIONS
WITH 100% COMPLETE SOLUTIONS |
LATEST UPDATE
Exhaust fans with ductwork connected to both sides shall have access for cleaning and inspection within
- correct answer-85 B 802.10.8




_____ of each side of the fan.(A) 1 foot (C) 5 feet(B) 3 feet (D) 6 feet - correct answer-86 D 504.5




When a closet is designed for the installation of a clothes dryer, a minimum opening of _____ square
inches for makeup air shall be provided.(A) 100 (C) 175(B) 150 (D) 200 - correct answer-87 B 803.2.6




Wall terminations of solid-fuel exhaust systems shall be _____.(A) 12 foot above grade (C) prohibited(B)
permitted (D) screened - correct answer-88 C 405.0




For canopy-type commercial cooking hoods, the inside edge thereof shall overhang or extend a
horizontal - correct answer-89 B 405.3




distance beyond the edge of the cooking surface not less than _____ inch(es).(A) 1 (C) 6(B) 3 (D) 12 -
correct answer-90 C 1312.1.2(A)




Greases filters shall be installed at an angle of not less than _____ degrees from the horizontal.(A) 30 (C)
60(B) 45 (D) 90. - correct answer-91 C 802.13

,All clothes dryers installed for multiple-family or public use shall be equipped with _____.(A) approved
backflow prevention devices (C) approved lint screens(B) approved safety shutoff devices (D) Type II
hood. - correct answer-92 C 927.2(A)(2)




Automatic shutoff is not required when all occupied rooms served by the air-handling equipment have
direct exit to the exterior and the travel distance does not exceed _____ feet.(A) 100 (C) 75(B) 50 (D)
150. - correct answer-93 C 405.2




Excess refrigerants may be stored _____. (A)in a securely fenced yard with a locked gate (C) as required
by the Fire Code(B) in a mechanical room (D) in a machinery room - correct answer-94 D Table 6-9




Electrical equipment shall be approved for the class of use as provided in the _____ Code.(A) Uniform
Mechanical (C) Building(B) Uniform Plumbing (D) Electrical. - correct answer-95 B 405.3




Appliances located in a confined space with all air taken from the inside of the building shall have each -
correct answer-96 D 803.1.9




opening for combustion air sized at 1 square inch per _____ Btu/h.(A) 1,000 (C) 4,000(B) 2,000 (D) 5,000
- correct answer-97 D 405.3




Every evaporative cooler supported on an aboveground platform shall be elevated from the ground by
at - correct answer-98 B 308.0

, least _____ the adjoining ground level.(A) 3 inches below (C) 6 inches above(B) 3 inches above (D) 6
inches below. - correct answer-99 C 803.1.10




Motorized louvers shall be _____ with the equipment so they are proven in the full open position to
main - correct answer-100 B 1125.0




burner ignition and during main burner operation.(A) installed (C) listed(B) interlocked (D) shipped -
correct answer-...




The minimum distance from the ground to any metal duct shall not be less than _____ inches.(A) 2 (C)
6(B) 4 (D) 12. - correct answer-...




A commercial clothes dryer connected to a moisture exhaust duct shall be installed in accordance with
the - correct answer-...




_____ instructions.(A) fire marshal's (C) manufacturer's(B) building official's (D) installer's. - correct
answer-...




Vent connectors shall be securely supported, and joints fastened with _____.(A) duct tape (C) sheet
metal screws(B) solder joints (D) welded joints. - correct answer-...




Vent connectors shall be pitched upward from the appliance at least _____ inch per foot.(A) 1 ⁄8 (C) 1 ⁄2
(B) 1 ⁄4 (D) 1. - correct answer-...
$20.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
Examchemist

Get to know the seller

Seller avatar
Examchemist Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
2
Member since
9 months
Number of followers
0
Documents
1067
Last sold
23 hours ago
Examchemist

Welcome To my Store My Goal is to help you achieve your desired grades). I specialize in providing detailed, high-quality study guides, Exams assignments with correct verified answers, Research papers and Test Banks all verified correct. you'll find past and recent revised and verified study materials. Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!

Read more Read less
0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions