• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 56 pages
Exam (elaborations)

Maine Journeyman Plumbing Q2 {Gas Piping & Fuel Gas Code (Gasfitting)} Comprehensive Frequently Tested Questions With Verified Multiple Choice and Conceptual Actual 100% Correct Detailed Answers Guaranteed Pass!!Current Update!!

Document preview thumbnail
Preview 4 out of 56 pages

Maine Journeyman Plumbing Q2 {Gas Piping & Fuel Gas Code (Gasfitting)} Comprehensive Frequently Tested Questions With Verified Multiple Choice and Conceptual Actual 100% Correct Detailed Answers Guaranteed Pass!!Current Update!! 1. Non-metallic gas piping installed underground outdoors must transition below grade to a: A. Steel coupling B. Dielectric fitting C. Anodeless riser D. Flexible connector Correct Answer: C 2. Under MGL Chapter 142, propane is referred to as: A. Liquefied natural gas B. Compressed petroleum gas C. Undiluted liquefied petroleum D. Commercial fuel gas Correct Answer: C 3. Gas piping systems extending from the service meter outlet to appliance shutoff valves must withstand a pressure test of not less than: A. 3 inches of mercury B. 6 inches of mercury or 3 PSIG for 10 minutes C. 10 PSIG for 5 minutes D. 15 PSIG for 30 minutes Correct Answer: B 4. Test pressure for gas piping must be measured with a device calibrated in increments of no more than: A. 1.0 PSIG B. 0.5 PSIG C. 0.25 PSIG D. 0.1 PSIG Correct Answer: D 5. Unless an emergency exists, gas piping systems shall not be placed into service until they are tested in the presence of the inspector and: A. The gas supplier B. The building owner C. Approved D. The fire department Correct Answer: C

Content preview

Maine Journeyman Plumbing Q2 {Gas Piping
& Fuel Gas Code (Gasfitting)} 2026-2027
Comprehensive Frequently Tested Questions
With Verified Multiple Choice and Conceptual
Actual 100% Correct Detailed Answers

Guaranteed Pass!!Current Update!!


1. Non-metallic gas piping installed underground outdoors must transition
below grade to a:
A. Steel coupling
B. Dielectric fitting
C. Anodeless riser
D. Flexible connector
Correct Answer: C


2. Under MGL Chapter 142, propane is referred to as:
A. Liquefied natural gas
B. Compressed petroleum gas
C. Undiluted liquefied petroleum
D. Commercial fuel gas
Correct Answer: C

,3. Gas piping systems extending from the service meter outlet to appliance
shutoff valves must withstand a pressure test of not less than:
A. 3 inches of mercury
B. 6 inches of mercury or 3 PSIG for 10 minutes
C. 10 PSIG for 5 minutes
D. 15 PSIG for 30 minutes
Correct Answer: B


4. Test pressure for gas piping must be measured with a device calibrated in
increments of no more than:
A. 1.0 PSIG
B. 0.5 PSIG
C. 0.25 PSIG
D. 0.1 PSIG
Correct Answer: D


5. Unless an emergency exists, gas piping systems shall not be placed into
service until they are tested in the presence of the inspector and:
A. The gas supplier
B. The building owner
C. Approved
D. The fire department
Correct Answer: C


6. A 2-inch gas pipe run horizontally for 142.5 feet would require a total pitch of
approximately:

,A. 1¾ inches
B. 2 inches
C. 2⅜ inches
D. 3 inches
Correct Answer: C


7. The required duration of the gas piping pressure test is a minimum of:
A. 5 minutes
B. 8 minutes
C. 10 minutes
D. 15 minutes
Correct Answer: C


8. Which test medium is prohibited when testing gas piping systems?
A. Nitrogen
B. Air
C. Carbon dioxide
D. Oxygen
Correct Answer: D


9. During the process of turning gas into a new system, the entire system shall
be:
A. Purged only
B. Pressurized only
C. Inspected
D. Painted
Correct Answer: C

, 10. Prior to cutting into a gas main, what must be done?
A. Shut off downstream appliances
B. Pressure purge the contents of the main to an outside location
C. Increase test pressure
D. Install a bypass valve
Correct Answer: B


11. The approximate weight of a 2-inch steel pipe is:
A. 2 lbs per foot
B. 3 lbs per foot
C. 3½ lbs per foot
D. 5 lbs per foot
Correct Answer: C


12. The approximate gallon capacity of the interceptor shown is:
A. 800–900 gallons
B. 1000–1100 gallons
C. 1214–1216 gallons
D. 1500 gallons
Correct Answer: C


13. The approximate circumference of a Schedule 40 black steel gas pipe with a
3.5-inch OD is:
A. 9 inches
B. 10 inches

Document information

Uploaded on
December 17, 2025
Number of pages
56
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy
3.8
(116)
Sold
780
Followers
432
Items
8857
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions