• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 21 pages
Exam (elaborations)

Illinois State Plumbing {Systems Testing, Installation, and Fixture Requirement 1} Comprehensive Frequently Tested Questions With Verified Multiple Choice and Conceptual Actual 100% Correct Detailed Answers Guaranteed Pass!!Current Update!!

Document preview thumbnail
Preview 3 out of 21 pages

Illinois State Plumbing {Systems Testing, Installation, and Fixture Requirement 1} Comprehensive Frequently Tested Questions With Verified Multiple Choice and Conceptual Actual 100% Correct Detailed Answers Guaranteed Pass!!Current Update!! 1. Testing of a building sewer shall be conducted using a minimum head of water of: A. 5 feet for 10 minutes B. 8 feet for 10 minutes C. 10 feet for 15 minutes D. 12 feet for 30 minutes Correct Answer: C 2. When tested by air, a DWV system shall be tested at: A. 3 PSI for 10 minutes B. 5 PSI or 10 inches of mercury for 15 minutes C. 7 PSI for 30 minutes D. 10 PSI for 5 minutes Correct Answer: B 3. When a smoke test is used to verify gas tightness of a DWV system, the applied pressure shall be equivalent to: A. ½-inch water column for 10 minutes B. 1-inch water column for 15 minutes C. 2-inch water column for 10 minutes D. 3-inch water column for 30 minutes Correct Answer: B 4. When an air test of rough plumbing requires a test pressure of 5 PSI, the test gauge shall be calibrated in increments of: A. 0.25 PSI B. 0.20 PSI C. 0.10 PSI D. 0.05 PSI Correct Answer: C 5. Trenches excavated parallel to a footing shall not extend more than: A. 12 inches below the footing B. 18 inches below the footing C. The bearing plane at a 45-degree angle D. The depth of the footing Correct Answer: C

Content preview

Illinois State Plumbing {Systems Testing,
Installation, and Fixture Requirement 1}
2026-2027 Comprehensive Frequently Tested
Questions With Verified Multiple Choice and
Conceptual Actual 100% Correct Detailed Answers

Guaranteed Pass!!Current Update!!


1. Testing of a building sewer shall be conducted using a minimum head of water
of:
A. 5 feet for 10 minutes
B. 8 feet for 10 minutes
C. 10 feet for 15 minutes
D. 12 feet for 30 minutes
Correct Answer: C


2. When tested by air, a DWV system shall be tested at:
A. 3 PSI for 10 minutes
B. 5 PSI or 10 inches of mercury for 15 minutes
C. 7 PSI for 30 minutes
D. 10 PSI for 5 minutes
Correct Answer: B

,3. When a smoke test is used to verify gas tightness of a DWV system, the
applied pressure shall be equivalent to:
A. ½-inch water column for 10 minutes
B. 1-inch water column for 15 minutes
C. 2-inch water column for 10 minutes
D. 3-inch water column for 30 minutes
Correct Answer: B


4. When an air test of rough plumbing requires a test pressure of 5 PSI, the test
gauge shall be calibrated in increments of:
A. 0.25 PSI
B. 0.20 PSI
C. 0.10 PSI
D. 0.05 PSI
Correct Answer: C


5. Trenches excavated parallel to a footing shall not extend more than:
A. 12 inches below the footing
B. 18 inches below the footing
C. The bearing plane at a 45-degree angle
D. The depth of the footing
Correct Answer: C


6. A water supply system shall be proven tight under water pressure not less
than the working pressure of the system or by an air test of at least:
A. 25 PSI
B. 40 PSI

, C. 50 PSI
D. 75 PSI
Correct Answer: C


7. Copper piping passing through bored holes in wood studs shall be protected
by shield plates unless the hole is at least:
A. 1 inch from the edge
B. 1¼ inches from the edge
C. 1½ inches from the edge
D. 2 inches from the edge
Correct Answer: C


8. Required shield plates protecting piping through framing members shall
extend at least:
A. 1 inch above and below plates
B. 1½ inches above and below plates
C. 2 inches above sole plates and below top plates
D. 3 inches above and below plates
Correct Answer: C


9. A building drain passing through a foundation wall without a relieving arch
shall pass through a sleeve sized:
A. One pipe size larger
B. Two pipe sizes larger
C. Three pipe sizes larger
D. Equal to the pipe size
Correct Answer: B

Document information

Uploaded on
December 17, 2025
Number of pages
21
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy
3.8
(116)
Sold
780
Followers
432
Items
8857
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions