Master Plumber (DWV Systems) Comprehensive Frequently Tested Exam Questions With Verified Multiple Choice and Conceptual Actual 100% Correct Detailed Answers Guaranteed Pass!!Current Update!! 1. The minimum depth of gas piping underground is ____ A. 12" B. 18" C. 24" D. 30" - ANSWER A. 12" 2. Where nonferrous pipe is brazed for gas piping, the brazing materials shall have a melting point in excess of _____ degrees Fahrenheit A. 600 B. 800 C. 1000 D. 1400 - ANSWER C. 1000 3. The temperature of water for tankless water heaters shall not be greater than ___ degrees Fahrenheit A. 120 B. 130 C. 140 D. 160 - ANSWER C. 140 4. The minimum combustible clearance of Type B vent piping is ____ A. Listed in the code B. Listed by the manufacturer and stamped on the pipe C. 2" D. 6" - ANSWER B. Listed by the manufacturer and stamped on the pipe 5. Fixture connections which may be serviced through an access panel are considered A. Accessible B. Readily accessible C. Not accessible D. Exposed - ANSWER A. Accessible

Content preview

Master Plumber (DWV Systems) 2026-2027
Comprehensive Frequently Tested Exam Questions
With Verified Multiple Choice and Conceptual
Actual 100% Correct Detailed Answers

Guaranteed Pass!!Current Update!!


1. The minimum depth of gas piping underground is ____
A. 12"
B. 18"
C. 24"
D. 30" - ANSWER A. 12"


2. Where nonferrous pipe is brazed for gas piping, the brazing materials shall
have a melting point in excess of _____ degrees Fahrenheit
A. 600
B. 800
C. 1000
D. 1400 - ANSWER C. 1000


3. The temperature of water for tankless water heaters shall not be greater
than ___ degrees Fahrenheit
A. 120
B. 130
C. 140
D. 160 - ANSWER C. 140


4. The minimum combustible clearance of Type B vent piping is ____

, A. Listed in the code
B. Listed by the manufacturer and stamped on the pipe
C. 2"
D. 6" - ANSWER B. Listed by the manufacturer and stamped on the
pipe


5. Fixture connections which may be serviced through an access panel are
considered
A. Accessible
B. Readily accessible
C. Not accessible
D. Exposed - ANSWER A. Accessible


6. The part of the lowest piping of a drainage system, which recieves the
discharge from soil, waste and other drainage pipes inside the walls of the
building and conveys it to a point 2' outside the building wall is a
A. House drain
B. House sewer
C. Waste pipe
D. Soil stack - ANSWER A. House drain


7. A vertical vent that is a continuation of the drain to which it connects is a
A. Circuit vent
B. Relief vent
C. Continuous vent
D. Branch Vent - ANSWER C. Continuous vent


8. A vent which also serves as a drain is a
A. Island Vent

, B. Vent Stack
C. Loop Vent
D. Wet Vent - ANSWER D. Wet Vent


9. A stack is always
A. Straight
B. Horizontal
C. Vertical
D. Lengthy - ANSWER C. Vertical


10.A pipe which makes an angle of no more than 45 degrees with the vertical is
considered
A. Vertical
B. Horizontal
C. Diagonal
D. Bent pipe - ANSWER A. Vertical


11.The vertical depth of a trap seal is measured from
A. The crown weir to the top of the dip of the trap
B. The inlet of the trap to the bottom of the trap
C. The crown weir to the bottom dip of the trap
D. The inlet of the trap to the outlet of the trap - ANSWER A. The
crown weir to the top of the dip of the trap


12.The principal artery of the venting system to which branches may be
connected is called
A. Branch vent
B. Vertical vent
C. Vent

, D. Main vent - ANSWER D. Main vent


13.A pressure surge absorbing device operating through the compressibility of
air is called
A. Backflow preventer
B. Air Chamber
C. Flushometer Valve
D. Hammer Arrestor - ANSWER D. Hammer arrestor


14.A device installed in a drainage system to prevent reverse flow is a
A. Sewage valve
B. Check valve
C. Backwater Valve
D. Backflow Valve - ANSWER C. Backwater Valve


15.Any pressure less than that exterted by atmosphere is
A. Vacuum
B. Negative Pressure
C. Positive Pressure
D. Atmospheric Pressure - ANSWER A. Vacuum


16.A plugged fitting located at the base of all soil stacks is called
A. Stack cleanout
B. Stack vent
C. Vent stack
D. Main cleanout - ANSWER A. Stack cleanout

Document information

Uploaded on
December 17, 2025
Number of pages
42
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EWLindy
3.8
(116)
Sold
775
Followers
432
Items
8741
Last sold
2 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions