OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS OIL BURNER LICENSE QUESTIONS WITH DETAILED VERIFIED ANSWERS

Content preview

Page | 1



OIL BURNER LICENSE QUESTIONS WITH
DETAILED VERIFIED ANSWERS
What is the first thing a tech should do when arriving at a no combustion
call? Ans: Ask how many times the customer reset the unit.

What is the best long term solution for preventing a clogged nozzle?
Ans: -Remove any underground storage tanks.

-Install a quality oil filter.

-Cut the suction line 10" above the tank outlet to prevent sludge.

Hot water and steam valves are interchangeable. Ans: False

When in the presence of a flame, a cad cell normally reads.. Ans: 300-
1000 ohms

If a pump is used to bring oil to a level higher than the tank, an oil safety
valve is required. Ans: True

On a call where a hydronic heat system is putting out too much heat on
the stack, the issue may be.. Ans: -Too much draft.

-Not enough combustion air in the equipment room.

-Air leakage into chamber.

A high CO2 reading is caused by.. Ans: Incomplete combustion

An often overlooked cause of a high CO2 reading is.. Ans: Not enough
combustion air in the equipment room.

When multiple pumps are wired together in a heating system, they
should be wired in.. Ans: parallel

In a series circuit.. Ans: Current has one path.

, Page | 2

When 2 burners are connected to the same chimney.. Ans: Sufficient
draft must be obtained to operate both units.

The ignition transformer is located.. Ans: In the primary control.

When safeties are wired in series one safety will affect the operation of
the others. Ans: True

A stack switch is no longer allowed to be installed or replaced because..
Ans: It's safety cutout time is higher than what is now required.

What is a power venter and what does it do? Ans: An electrical device
that sends fluid gases into the chimney connector.

A burner in a confined space using 1 GPH of #2 fuel oil requires what size
permanent opening for combustion air? Ans: 140"

The difference between an adjustable flame retention burner and a fixed
flame retention burner is? Ans: Air inlets can be adjusted

Ignitor position can be adjusted

Fuel can be adjusted

Oil tank design, construction, installation and testing shall be in
accordance with.. Ans: 527 CMR 9.0

Heat is a form of.. Ans: Energy

If a burner is operational but the circulator pump isn't running.. Ans:
The pump relay is not working correctly

A method of dealing with low viscosity/cold temps with #2 oil? Ans:
Increase pump pressure/ decrease nozzle size

What is needed at the outlet of an oil tank? Ans: Thermal safety valve

Where do you obtain an installation permit for oil burners? Ans: Fire
Dept

, Page | 3

How many Btu's approximately in 1 gal of #2 fuel oil? Ans: 140,000
btu's

Solid state ignition is superior to spark because Ans: It is not affected by
reduced voltage

What is an installation? Ans: The complete setting in place, ready for
operation, of an oil burner appliance together with its accessories and
equipment.

How far must a power vent terminate from an opening or window? Ans:
4'

A pump in a one pipe system that is full of air can be self purged. Ans:
False

List the minimum size of an oil supply line. Ans: 3/8"

A material with electrons so loose it allows voltage to pass with little or
no resistance.. Ans: Is a conductor

If a high limit goes off, what does a low water switch do? Ans: Maintains
water temperature

What is flashpoint an indicator of? Ans: Minimum temperature oil will
ignite but not continue to burn.

What travels on the inside of the wire? Ans: Volts

What does readily accessible mean pertaining to oil burning equipment?
Ans: Capable of being reached easily and quickly for operation,
maintenance or inspection.

What is the minimum vent pipe on an oil tank? Ans: 1 1/4"

What causes corrosion on a flue pipe? Ans: When the flue pipe is
operating below the dew point temperature.

What are the methods to prevent oil waxing? Ans: Put additives in the
fuel.

Document information

Uploaded on
December 8, 2025
Number of pages
23
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Ivie
3.4
(7)
Sold
33
Followers
1
Items
8529
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.