P-99 / Low PSI Oil Burner Operator

A correctly adjusted oil burner flame could have an ____ coloured flame body with small ____,
barely cloudy recommendations. - ANS-Orange / Red

A risky situation occurs while oil pumped to the combustion chamber is not nicely ____. -
ANS-Atomized.

A faulty oil cut-off valve can lead to ____. - ANS-After-drip.

A purple, smoky flame is a sign of a ____. - ANS-Lack of air.

A faraway manage for oil burner is furnished to forestall what? - ANS-The flow of oil to any
burner.

A white, remarkable flame is an indication of ____. - ANS-Excess air.

Acceptance checks: Boilers shall no longer be placed in operation upon completion of
construction till they had been ____ and an equipment use allow has been issued through the
commissioner. - ANS-Inspected and examined.

After any gas burning system restore for which an authorized operator is required, such
operator shall additionally check the upkeep and be ____ whilst the device is began. -
ANS-Present.

After-drip can cause ____. - ANS-Carbon deposit build-up.

All heating, combustion, and cooking equipment will be furnished with insulation or the building
creation shall be hearth included, so that in operation the surface of combustible creation
substances will no longer be raised to a temperature higher than ____. - ANS-a hundred and
seventy ̊ F

An immoderate air deliver can also ____ the flame. - ANS-Blow out.

Assuming an outdoor place is impractical, in which can the far flung manage for oil burner be
located? - ANS-Immediately in the room in which the burner is placed.

At what RPM is oil atomized? - ANS-three,four hundred

Between what temperatures does the pre-heater convey the oil to? - ANS-one hundred sixty° -
180°F

, Between what temperatures must no. 6 gasoline-oil be maintained in the storage tank? - ANS-a
hundred ̊ - 130 ̊F

Blockage inside the chimney or flue passage will cause the boiler room to become ____. -
ANS-Filled with smoke.

Burner puff-again is most customarily due to a ____ in ignition. - ANS-Delay.

Dampers in flues will be constructed so that they can not completely ____ the passage of flue
gases at any time. - ANS-Cut off.

Dense, black smoke and soot is an indication of ____. - ANS-Insufficient air.

Each time one pound of carbon is burned, ____ BTU of heat are liberated. - ANS-14,544

Every oil burning set up that isn't always absolutely automated or calls for preheating shall be
operated by means of, or beneath, the direct supervision of a person holding a ____ issued by
using the hearth commissioner. - ANS-COF

For operated by hand burners using garage tanks with 60 gallons or much less ability, where
can the far flung manipulate for oil burner be installed? - ANS-In the supply strains between the
tank and burner.

For what motive is stress in a storage tank prohibited? - ANS-Discharging oil.

Heat within the combustion chamber that maintains the fireplace after the ignition is turned off is
known as ____. - ANS-Reflected heat.

Heavy oil together with no. 6 gas-oil is raised to approximately ____ before it enters the
combustion process. - ANS-one hundred eighty°F

How frequently must no. 6 gasoline-oil burner nozzles be wiped clean? - ANS-Daily.

If the fuel is not furnished with the proper amount of oxygen, carbon monoxide can be produced,
and only ____ BTU of heat are liberated. - ANS-4,480

If the oil spray combination contacts the ____ of the combustion chamber, it'll cause a smoky
fire. - ANS-Walls.

If ventilation for the cause of combustion is supplied robotically, the ventilating system shall be
____ interlocked with the burner. - ANS-Electrically.

In low stress oil burners, the oil and air combination is added to the nozzle at a strain between
____. - ANS-1 - 15 psi.

Document information

Uploaded on
November 24, 2025
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AllLegitExams
3.8
(43)
Sold
125
Followers
8
Items
2331
Last sold
1 month ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions