All of the following artifacts except ________ occur along the phase encoding axis ✔Correct
Answer-chemical shift (occurs along the frequency axis)
Magnetic susceptibility artifacts are more prominent with _____________ sequences ✔Correct
Answer-GRE
A remedy for a Gibbs truncation artifact would be: ✔Correct Answer-To correct for Gibbs
truncation artifact, increase the number of phase encodings or reduce the FOV (while maintaining
matrix)
The largest ventricle in the heart is the _______ and is identified by Letter ____ in Image 66.
✔Correct Answer-Left ventricle, D
Calculate the effective TR for a patient with a heart rate of 70 beats / min. ✔Correct Answer-
60, = 857
The HEIGHT of a peak on an MR spectrum correlates to the _________ of a substance that was
detected. ✔Correct Answer-AMOUNT
Contrast in Diffusion Weighted Imaging (DWI) depends on:
I. The degree to which molecular mobility is impaired (water restriction)
II. The sensitivity of the sequence to Brownian motion
III. T1 relaxation time
IV. The direction of water diffusion
V. T2 relaxation time ✔Correct Answer-Contrast in Diffusion Weighted Imaging (DWI) depends on
the degree to which molecular mobility is impaired (water restriction), the sensitivity of the
sequence to Brownian motion, and the direction of water diffusion
The final result in a perfusion study is ✔Correct Answer-A set of calculated images which indicate
various flow characteristics
The final result in a spectroscopy study is ✔Correct Answer-A spectrum of specific detected
metabolite
-Spectroscopy (MRS) allows doctors to obtain biochemical information about the chemical
components in tissues (metabolites) of the human body in a non-invasive way.
The imaging technique that employs a very rapid pulse sequence while the patient is at rest or
performing a task is: ✔Correct Answer-functional MRI
the corpus callosum primarily consists of ✔Correct Answer-white matter
If the TR in a gradient echo sequence is less than the T2 (or T2*), the resulting condition is known as:
✔Correct Answer-steady state
, A gradient echo sequence in which all the remaining residual transverse magnetization is removed
prior to the next excitation pulse is known as: ✔Correct Answer-incoherent or spoiled
In a Fast Spin Echo (FSE) sequence, acquired with a long TE, yielding T2 weighted images, scan time
can be reduced by: ✔Correct Answer-using longer ETL
In a Fast Spin Echo (FSE) sequence, acquired with a short echo time (TE), yielding T1 or PD weighted
images, blurring can be reduced by ✔Correct Answer-using shorter ETL
The structures that comprise the rotator cuff in the shoulder are:I. Deltoid muscleII. Subscapularis
muscle and tendonIII. Infraspinatus muscle and tendonIV. Teres minor muscle and tendonV.
Supraspinatus muscle and tendonVI. Trapezius muscle and tendon ✔Correct Answer-II, III, IV and V
-The rotator cuff is comprised of the subscapularis muscle and tendon, infraspinatus muscle and
tendon,teres minor muscle and tendon and the supraspinatus muscle and tendon
T2 weighted FLAIR (fluid attenuated inversion recovery) sequences are typically used for evaluation
of: ✔Correct Answer-white matter disease
Short TAU inversion recovery (STIR) sequences are typically used for the evaluation of all the
following EXCEPT: ✔Correct Answer-fluid CSF
- Short TAU inversion recovery (STIR) sequences are typically used for the evaluation of compression
fracture, lesions within retro-orbital fat, musculoskeletal contusions and fat suppression
If the pulse sequence shown in Image 77 were a fast spin echo sequence, the number of lines of k-
space filled for each TR period would be: ✔Correct Answer-2
When a gradient echo sequence is selected for fast, breath hold dynamic contrast-enhanced imaging
of the abdomen, _____________ is utilized. ✔Correct Answer-spoiling
Gradient echo sequences requiring high signal from fluid are known as all of the following EXCEPT:
✔Correct Answer-incoherent GRE
- Gradient echo sequences requiring high signal from fluid are known as T2* gradient echo, Steady-
state gradient echo or coherent gradient echo. Incoherent gradient echo (or spoiled gradient echo)
sequences yield T1 contrast due to the removal of residual transverse magnetization before the next
excitation.
Dynamic enhanced MRA sequences of the mesenteric arteries are performed using ✔Correct
Answer-incoherent GRE
Gradient echo sequences can yield either T1 or T2* characteristics, with influences caused by all of
the following EXCEPT ✔Correct Answer-inversion time
Which of the following field strengths would require the shortest TI time to suppress the signal from
fat when performing a STIR sequence in an MRI of the ankle? ✔Correct Answer-0.5t
If the desire is to null the signal from a specific tissue using an inversion recovery sequence, the
inversion time (TI) selected should be ______ of the T1 relaxation time of that tissue. ✔Correct
Answer-69%
When parallel imaging techniques are utilized, a low resolution __________ is acquired prior to the
acquisition. ✔Correct Answer-calibration scan
Answers| Actual Complete Update |Guaranteed to
Pass| Just Released
All of the following artifacts except ________ occur along the phase encoding axis ✔Correct
Answer-chemical shift (occurs along the frequency axis)
Magnetic susceptibility artifacts are more prominent with _____________ sequences ✔Correct
Answer-GRE
A remedy for a Gibbs truncation artifact would be: ✔Correct Answer-To correct for Gibbs
truncation artifact, increase the number of phase encodings or reduce the FOV (while maintaining
matrix)
The largest ventricle in the heart is the _______ and is identified by Letter ____ in Image 66.
✔Correct Answer-Left ventricle, D
Calculate the effective TR for a patient with a heart rate of 70 beats / min. ✔Correct Answer-
60, = 857
The HEIGHT of a peak on an MR spectrum correlates to the _________ of a substance that was
detected. ✔Correct Answer-AMOUNT
Contrast in Diffusion Weighted Imaging (DWI) depends on:
I. The degree to which molecular mobility is impaired (water restriction)
II. The sensitivity of the sequence to Brownian motion
III. T1 relaxation time
IV. The direction of water diffusion
V. T2 relaxation time ✔Correct Answer-Contrast in Diffusion Weighted Imaging (DWI) depends on
the degree to which molecular mobility is impaired (water restriction), the sensitivity of the
sequence to Brownian motion, and the direction of water diffusion
The final result in a perfusion study is ✔Correct Answer-A set of calculated images which indicate
various flow characteristics
The final result in a spectroscopy study is ✔Correct Answer-A spectrum of specific detected
metabolite
-Spectroscopy (MRS) allows doctors to obtain biochemical information about the chemical
components in tissues (metabolites) of the human body in a non-invasive way.
The imaging technique that employs a very rapid pulse sequence while the patient is at rest or
performing a task is: ✔Correct Answer-functional MRI
the corpus callosum primarily consists of ✔Correct Answer-white matter
If the TR in a gradient echo sequence is less than the T2 (or T2*), the resulting condition is known as:
✔Correct Answer-steady state
, A gradient echo sequence in which all the remaining residual transverse magnetization is removed
prior to the next excitation pulse is known as: ✔Correct Answer-incoherent or spoiled
In a Fast Spin Echo (FSE) sequence, acquired with a long TE, yielding T2 weighted images, scan time
can be reduced by: ✔Correct Answer-using longer ETL
In a Fast Spin Echo (FSE) sequence, acquired with a short echo time (TE), yielding T1 or PD weighted
images, blurring can be reduced by ✔Correct Answer-using shorter ETL
The structures that comprise the rotator cuff in the shoulder are:I. Deltoid muscleII. Subscapularis
muscle and tendonIII. Infraspinatus muscle and tendonIV. Teres minor muscle and tendonV.
Supraspinatus muscle and tendonVI. Trapezius muscle and tendon ✔Correct Answer-II, III, IV and V
-The rotator cuff is comprised of the subscapularis muscle and tendon, infraspinatus muscle and
tendon,teres minor muscle and tendon and the supraspinatus muscle and tendon
T2 weighted FLAIR (fluid attenuated inversion recovery) sequences are typically used for evaluation
of: ✔Correct Answer-white matter disease
Short TAU inversion recovery (STIR) sequences are typically used for the evaluation of all the
following EXCEPT: ✔Correct Answer-fluid CSF
- Short TAU inversion recovery (STIR) sequences are typically used for the evaluation of compression
fracture, lesions within retro-orbital fat, musculoskeletal contusions and fat suppression
If the pulse sequence shown in Image 77 were a fast spin echo sequence, the number of lines of k-
space filled for each TR period would be: ✔Correct Answer-2
When a gradient echo sequence is selected for fast, breath hold dynamic contrast-enhanced imaging
of the abdomen, _____________ is utilized. ✔Correct Answer-spoiling
Gradient echo sequences requiring high signal from fluid are known as all of the following EXCEPT:
✔Correct Answer-incoherent GRE
- Gradient echo sequences requiring high signal from fluid are known as T2* gradient echo, Steady-
state gradient echo or coherent gradient echo. Incoherent gradient echo (or spoiled gradient echo)
sequences yield T1 contrast due to the removal of residual transverse magnetization before the next
excitation.
Dynamic enhanced MRA sequences of the mesenteric arteries are performed using ✔Correct
Answer-incoherent GRE
Gradient echo sequences can yield either T1 or T2* characteristics, with influences caused by all of
the following EXCEPT ✔Correct Answer-inversion time
Which of the following field strengths would require the shortest TI time to suppress the signal from
fat when performing a STIR sequence in an MRI of the ankle? ✔Correct Answer-0.5t
If the desire is to null the signal from a specific tissue using an inversion recovery sequence, the
inversion time (TI) selected should be ______ of the T1 relaxation time of that tissue. ✔Correct
Answer-69%
When parallel imaging techniques are utilized, a low resolution __________ is acquired prior to the
acquisition. ✔Correct Answer-calibration scan