ELECTRICAL JATC CODE DEFINITIONS EXAM QUESTIONS ANSWERED CORRECTLY GRADED A+ Ampacity - Answers The maximum current in amprees that a conductor can carry continuously under the conditions of use without exceeding its temperature rating Appliance - Answers Utilization equipment, generally other than industrial, that is normally built in standardize sizes or types and it's installed or connected as a unit to perform one or more functions such as clothes washing, air-conditioning, food mixing, deep frying and so forth Appliance branch circuit - Answers A branch circuit that supplies energy to one or more outlets to which appliances are to be connected and that has no permanently connected luminaires that are not a part of an appliance Approved - Answers Acceptable to the authority having jurisdiction Arc-fault circuit interrupter - Answers A device intended to provide protection from the effects of arc fault by recognizing characteristics unique to arcing and by functioning to De-energize the circuit when the fault is detected Authority having jurisdiction (AHJ) - Answers An organization, office, or individual responsible for enforcing the requirements of the code or standard, or for approving equipment, materials, and installation or procedure Bonded (bonding) - Answers Connected to establish electrical continuity and conductivity Bonding jumper, equipment - Answers The connection between two or more portions of equipment grounding conductor Bonding jumper, main - Answers The connection between the grounded circuit conductor and thr equipment grounding conductor At the service Bonding jumper, system - Answers The connection between the grounded circuit conductor and the supply side bonding jumper or the equipment grounding conductor or both at a separately derived system Branch circuit - Answers The circuit conductors between the final overcurrent device protecting the circuit and the outlet Building - Answers A structure that stands alone or that is cut off from ajoining structures by firewalls with all openings therein protected by approved fire doors Cabinet - Answers And enclosure that is designed for either surface mount or flush mounting and is provided with a frame mat or trim and which a swingingdoor or doors are or can be hung Circuit breaker - Answers Hey device designed to open and close a circuit by non-automatic means and open the circuit automatically on a predetermined overcurrent without damage to itself when properly applied within its rating Concealed - Answers Rendered inaccessible by the structure or the finish of the building Continuous duty - Answers Operation at a substantially constant load for ideffentially long time Continuous load - Answers A load were maximum current is expected to last 3 hours or more Controller - Answers A device or group of devices that serves to govern, in some pre-determined manner, the electric power delivered to the apparatus to which it is connected Covered conductor - Answers A conductor encased within material of composition Cutout box - Answers And enclosure designed for surface mounting that has swinging doors or

Show more Read less
Institution
JATC
Course
JATC









Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
November 20, 2025
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ELECTRICAL JATC CODE DEFINITIONS EXAM QUESTIONS ANSWERED CORRECTLY GRADED
A+

Ampacity - Answers The maximum current in amprees that a conductor can carry continuously
under the conditions of use without exceeding its temperature rating

Appliance - Answers Utilization equipment, generally other than industrial, that is normally built
in standardize sizes or types and it's installed or connected as a unit to perform one or more
functions such as clothes washing, air-conditioning, food mixing, deep frying and so forth

Appliance branch circuit - Answers A branch circuit that supplies energy to one or more outlets
to which appliances are to be connected and that has no permanently connected luminaires
that are not a part of an appliance

Approved - Answers Acceptable to the authority having jurisdiction

Arc-fault circuit interrupter - Answers A device intended to provide protection from the effects of
arc fault by recognizing characteristics unique to arcing and by functioning to De-energize the
circuit when the fault is detected

Authority having jurisdiction (AHJ) - Answers An organization, office, or individual responsible
for enforcing the requirements of the code or standard, or for approving equipment, materials,
and installation or procedure

Bonded (bonding) - Answers Connected to establish electrical continuity and conductivity

Bonding jumper, equipment - Answers The connection between two or more portions of
equipment grounding conductor

Bonding jumper, main - Answers The connection between the grounded circuit conductor and
thr equipment grounding conductor At the service

Bonding jumper, system - Answers The connection between the grounded circuit conductor and
the supply side bonding jumper or the equipment grounding conductor or both at a separately
derived system

Branch circuit - Answers The circuit conductors between the final overcurrent device protecting
the circuit and the outlet

Building - Answers A structure that stands alone or that is cut off from ajoining structures by
firewalls with all openings therein protected by approved fire doors

Cabinet - Answers And enclosure that is designed for either surface mount or flush mounting
and is provided with a frame mat or trim and which a swingingdoor or doors are or can be hung

Circuit breaker - Answers Hey device designed to open and close a circuit by non-automatic
means and open the circuit automatically on a predetermined overcurrent without damage to

, itself when properly applied within its rating

Concealed - Answers Rendered inaccessible by the structure or the finish of the building

Continuous duty - Answers Operation at a substantially constant load for ideffentially long time

Continuous load - Answers A load were maximum current is expected to last 3 hours or more

Controller - Answers A device or group of devices that serves to govern, in some pre-determined
manner, the electric power delivered to the apparatus to which it is connected

Covered conductor - Answers A conductor encased within material of composition

Cutout box - Answers And enclosure designed for surface mounting that has swinging doors or
covers secured directly to and telescoping with the walls of the enclosure

Damp location - Answers Locations protected from weather and not subject to saturation with
water or other liquids but subject to moderate degrees of moisture

Dead front - Answers Without live parts exposed to a person on the operating side of the
equipment

Device - Answers A unit of an electrical system other than a conductor that carries or controls
electrical energy as its primary function

Disconnecting means - Answers Device or group of devices or other means by which the
conductors of a circuit can be disconnected from their source of supply

Dry location - Answers They location not normally subject to dampness or wetness a location
classified as dry maybe temporarily subject to dampness or wetness as in the case of a building
under construction

Dusttight - Answers Enclosure constructed so that dust will not enter under specified task
conditions

Dwelling unit - Answers A single unit providing complete an independent living facilities for one
or more persons including permanent provisions for living sleeping cooking and sanitation

Effective ground fault current path - Answers In intentionally constructed low-impedance
electrically conductive path designed and intended to carry current under ground-fault
conditions from the point of a ground fault on a wiring system to the electrical supply source
and that facilitates the operation of the overcurrent protective device or ground-fault detectors

Enclosed - Answers Surrounded by a case housing fence or walls that prevent persons from
accidentally contacting energized parts

Enclosure - Answers The case or housing of an apparatus or the fence or wall surrounding and

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
315
Member since
1 year
Number of followers
16
Documents
27762
Last sold
15 hours ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

50 reviews

5
16
4
14
3
11
2
0
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions