Questions and Correct Answers | Verified
Answers | Brand New Version | Just Released
After any repairs to the boiler are made, ______ shall check the repairs and the
functioning of all ____ _____ and the positioning of the ______. ---------CORRECT
ANSWER-----------------Operators, control devices, valves
All heating and combustion equipment that is fired with solid, liquid, or gas fuels,
must comply with the requirements of the ____ _____ _____ code. ---------
CORRECT ANSWER-----------------Air pollution control
Low Temp Equipment have a temp of ____ degrees at the point of leaving the
equipment. ---------CORRECT ANSWER-----------------600 or less
Median Temp Equipment have a temp of between ___ and ___ degrees F at the
point of leaving the equipment under normal conditions. ---------CORRECT
ANSWER-----------------600 and 1000
High Temp Equipment have a temp of ____ or ____ degrees F leaving the
equipment. ---------CORRECT ANSWER-----------------1000 or greater
,Ventilation shall be capable of providing at least ____ cfm of air for each gallon of
oil per ____. ---------CORRECT ANSWER-----------------36, hour
If ventilation is supplied mechanically, the ventilation system shall be _____
interlocked with the _____, so that the vent system maintains a pressure no ___
than the _____ atmospheric pressure. ---------CORRECT ANSWER-----------------
Electrically, burner, less, outdoor
Flue Dampers shall be constructed so that they cannot completely ___ ___ the
passage of ___ ___ at any time. ---------CORRECT ANSWER-----------------Shut off,
flue gases
Tight closing dampers may be installed with approved automatic ____ and ______
controls. ---------CORRECT ANSWER-----------------Draft, combustion
Fuel oil shall mean hydrocarbon oils with a flash point not lower than ____
degrees F. ---------CORRECT ANSWER-----------------100
Commercial grades of fuel oil are ____, ____, ___, ____, and ___. ---------CORRECT
ANSWER-----------------1, 2, 4, 5, 6
, The use of crankcase refuse oil is ______. ---------CORRECT ANSWER-----------------
Prohibited
Overflow pipes shall not be _____ in size than the _____ pipe. ---------CORRECT
ANSWER-----------------Smaller, supply
Where a shut off valve is installed in the discharge line from an oil pump, a _____
_____ shall be installed in the discharge line between the pump the first shut off
valve. ---------CORRECT ANSWER-----------------Relief valve
A relief or pressure regulating valve shall be provided in the ____ piping system
on the _____ side of the shut off valves. ---------CORRECT ANSWER-----------------Oil,
heating
The heating of oil in the storage tanks shall be by means of _____ using low
pressure _____ or _____, or by means of _____ heaters. ---------CORRECT
ANSWER-----------------Coils, hot water, steam, electric
Where a single tank and burner exsist, a ____-____ valve shall be required in the
______ line at the tank and another at the ____. ---------CORRECT ANSWER----------
-------Shut-off, supply, burner