NFPA 99 6040 practice set Questions and Answers Verified 100% Correct The entrance to indoor locations containing positive pressure gases other than oxygen and medical air shall be labeled including: ______________ A Positive Pressure Gases B No Smoking or Open Flame C Room May Have Insufficient Oxygen - Open Door and Allow Room to Ventilate Before Entering D All of the above - ANSWER -All of the above If heat is necessary to keep an indoor manifold enclosure above 20oF and the manufacturer's recommended minimum ambient temperature it may be provided by: A Any in-room electric heating element B In-room heating element with a maximum temperature of 266oF C Fuel fired equipment in the room D Heat blanket with maximum temperature of 300oF - ANSWER -In-room heating element with a maximum temperature of 266oF Two entries/exits are required for ___________________ gas supplies. A Outdoor Cryogenic Gas Supplies only B Outdoor Cylinder Gas Supplies in an enclosure >200ft2 only C Indoor Gas Supplies only D Both A & B - ANSWER -Both A & B An existing outdoor Nitrous Oxide Manifold may continued to be used since it seldom falls below 20oF. A TRUE B FALSE - ANSWER -FALSE Indoor manifold rooms must be separated by ______ fire rated walls and floors with a ______ opening. A 1 hour, 1 hour B 2 hour, 1 hour C 1 hour, 3/4 hour D No wall fire rating is required - ANSWER -1 hour, 3/4 hour Only full or in-use cylinders are required to be prevented from falling by being secured with racks, chains, or other fastenings. Empty cylinders are not required to be secured. A TRUE B FALSE - ANSWER -FALSE Oxygen supplies greater than 350 psig may not use _______________ materials. A Copper B Stainless Steel C Polymeric D Brass - ANSWER -Polymeric Gas supply source relief valve vent lines must be labeled ____________. A with the proper pressure in psig B with medical gas pipe labels C by painting the correct CGA color D in a manner to distinguish them from medical gas pipeline - ANSWER -in a manner to distinguish them from medical gas pipeline Manifold rooms utilizing natural ventilation shall A have 2 non-closeable louvered openings B be vented directly to the outside without ductwork C provide cross ventilation D all of the above - ANSWER -all of the above Indoor manifold enclosures utilizing mechanical ventilation shall maintain positive pressure A TRUE B FALSE - ANSWER -FALSE A gas cylinder header consists of all of the following components with the exception of: A Filter B Pressure Indicator C Local alarm D Regulator - ANSWER -Local alarm A header for cryogenic liquid containers must have a ________________. A pressure relief valve B purge ports C quick disconnect D none of the above - ANSWER -pressure relief valve A __________ must be installed at the connection between the header and each cylinder lead (pigtail) to prevent a single pigtail leak from causing pressure loss of all cylinders connected to that same header. A Warning light B Local Alarm C Gauge D Check Valve - ANSWER -Check Valve Full and empty cylinder storage may not be in the same enclosure as a central supply system (medical or support gas manifold). A TRUE B FALSE - ANSWER -FALSE Permitted areas for piped medical gases outlets include all of the following with exception of: A Direct Respiration by a Patient B Calibration of patient respiration devices C Endoscopy or Sterile Processing Instrument Blow Down D Simulation centers for education of health care professionals - ANSWER Endoscopy or Sterile Processing Instrument Blow Down An auxiliary valve source connection must consist of all of the following except: A Installed on the source side (upstream) of the source valve B Must the same size as the main line C Include a removable plug or cap D Must be normally closed and secured - ANSWER -Installed on the source side (upstream) of the source valve Facilities may supply ______________ through a Concentrator Supply Source. A USP 93 Oxygen B 99% Oxygen Only C Compressed Medical Air D Nitrous Oxide - ANSWER -USP 93 Oxygen The primary and secondary headers for a gas cylinder manifold must each have an equal number of cylinders. A TRUE

Show more Read less
Institution
NFPA 99 6040
Course
NFPA 99 6040










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NFPA 99 6040
Course
NFPA 99 6040

Document information

Uploaded on
November 15, 2025
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NFPA 99 6040 practice set Questions and
Answers Verified 100% Correct
The entrance to indoor locations containing positive pressure gases other than
oxygen and medical air shall be labeled including: ______________
A Positive Pressure Gases
B No Smoking or Open Flame
C Room May Have Insufficient Oxygen - Open Door and Allow Room to
Ventilate Before Entering
D All of the above - ANSWER -All of the above

If heat is necessary to keep an indoor manifold enclosure above 20oF and the
manufacturer's recommended minimum ambient temperature it may be provided
by:
A Any in-room electric heating element
B In-room heating element with a maximum temperature of 266oF
C Fuel fired equipment in the room
D Heat blanket with maximum temperature of 300oF - ANSWER -In-room
heating element with a maximum temperature of 266oF

Two entries/exits are required for ___________________ gas supplies.
A Outdoor Cryogenic Gas Supplies only
B Outdoor Cylinder Gas Supplies in an enclosure >200ft2 only
C Indoor Gas Supplies only
D Both A & B - ANSWER -Both A & B

An existing outdoor Nitrous Oxide Manifold may continued to be used since it
seldom falls below 20oF.
A TRUE
B FALSE - ANSWER -FALSE

Indoor manifold rooms must be separated by ______ fire rated walls and floors
with a ______ opening.
A 1 hour, 1 hour
B 2 hour, 1 hour
C 1 hour, 3/4 hour
D No wall fire rating is required - ANSWER -1 hour, 3/4 hour

, Only full or in-use cylinders are required to be prevented from falling by being
secured with racks, chains, or other fastenings. Empty cylinders are not required to
be secured.
A TRUE
B FALSE - ANSWER -FALSE

Oxygen supplies greater than 350 psig may not use _______________ materials.
A Copper
B Stainless Steel
C Polymeric
D Brass - ANSWER -Polymeric

Gas supply source relief valve vent lines must be labeled ____________.
A with the proper pressure in psig
B with medical gas pipe labels
C by painting the correct CGA color
D in a manner to distinguish them from medical gas pipeline - ANSWER -in a
manner to distinguish them from medical gas pipeline

Manifold rooms utilizing natural ventilation shall
A have 2 non-closeable louvered openings
B be vented directly to the outside without ductwork
C provide cross ventilation
D all of the above - ANSWER -all of the above

Indoor manifold enclosures utilizing mechanical ventilation shall maintain
positive pressure
A TRUE
B FALSE - ANSWER -FALSE

A gas cylinder header consists of all of the following components with the
exception of:
A Filter
B Pressure Indicator
C Local alarm
D Regulator - ANSWER -Local alarm

A header for cryogenic liquid containers must have a ________________.
A pressure relief valve
B purge ports

, C quick disconnect
D none of the above - ANSWER -pressure relief valve

A __________ must be installed at the connection between the header and each
cylinder lead (pigtail) to prevent a single pigtail leak from causing pressure loss of
all cylinders connected to that same header.
A Warning light
B Local Alarm
C Gauge
D Check Valve - ANSWER -Check Valve

Full and empty cylinder storage may not be in the same enclosure as a central
supply system (medical or support gas manifold).
A TRUE
B FALSE - ANSWER -FALSE

Permitted areas for piped medical gases outlets include all of the following with
exception of:
A Direct Respiration by a Patient
B Calibration of patient respiration devices
C Endoscopy or Sterile Processing Instrument Blow Down
D Simulation centers for education of health care professionals - ANSWER -
Endoscopy or Sterile Processing Instrument Blow Down

An auxiliary valve source connection must consist of all of the following except:
A Installed on the source side (upstream) of the source valve
B Must the same size as the main line
C Include a removable plug or cap
D Must be normally closed and secured - ANSWER -Installed on the source side
(upstream) of the source valve

Facilities may supply ______________ through a Concentrator Supply Source.
A USP 93 Oxygen
B 99% Oxygen Only
C Compressed Medical Air
D Nitrous Oxide - ANSWER -USP 93 Oxygen

The primary and secondary headers for a gas cylinder manifold must each have an
equal number of cylinders.
A TRUE
$13.89
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
TopGradeGuru
1.5
(2)

Get to know the seller

Seller avatar
TopGradeGuru Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
10
Member since
1 year
Number of followers
0
Documents
2429
Last sold
1 month ago
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it's the go-to resource for exam preparation and academic success.

1.5

2 reviews

5
0
4
0
3
0
2
1
1
1

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions