Which of the following factors can have a negative effect on uterine
blood flow?
a. Hypertension
b. Epidural
c. Hemorrhage
d. Diabetes
e. All of the above - - SELECTED ANSWER👀 e. All of the above
How does the fetus compensate for decreased maternal circulating
volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement. - - SELECTED
ANSWER👀 b. Increases cardiac output by increasing it's heart rate.
Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
,d. No change - - SELECTED ANSWER👀 a. A decrease in the heart rate
What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels
e. A & C
f. A & B
g. C & D - - SELECTED ANSWER👀 g. C & D
The vagus nerve begins maturation 26 to 28 weeks. Its dominance
results in what effect to the FHR baseline?
a. Increases baseline
b. Decreases baseline - - SELECTED ANSWER👀 b. Decreases baseline
T/F: Oxygen exchange in the placenta takes place in the intervillous
space. - - SELECTED ANSWER👀 True
T/F: The parasympathetic nervous system is a cardioaccelerator. - -
SELECTED ANSWER👀 False
,T/F: Baroreceptors are stretch receptors which respond to increases or
decreases in blood pressure. - - SELECTED ANSWER👀 True
T/F: There are two electronic fetal monitoring methods of obtaining the
fetal heart rate: the ultrasound transducer and the fetal spiral
electrode. - - SELECTED ANSWER👀 True
T/F: Variability can be determined with the fetoscope. - - SELECTED
ANSWER👀 False
T/F: Because the ultrasound transducer and toco transducer are sealed
units, they can be dipped in warm water to make cleaning easier. - -
SELECTED ANSWER👀 False
T/F: The most common artifact with the ultrasound transducer system
for fetal heart rate is increased variability. - - SELECTED ANSWER👀
True
T/F: All fetal monitors contain a logic system designed to reject artifact.
- - SELECTED ANSWER👀 True
T/F: The monitor should always be tested before starting a tracing,
either external or internal mode and labeled a test. - - SELECTED
ANSWER👀 True
, T/F: The paper speed on the fetal monitor should always be set at
1cm/min. - - SELECTED ANSWER👀 False
T/F: Both internal and external monitoring methods are equally
accurate means of obtaining the fetal heart rate and contraction
patterns. - - SELECTED ANSWER👀 False
T/F: The external toco is usually placed over the uterine fundus to pick
up contractions. - - SELECTED ANSWER👀 True
T/F: The external toco gives measurable uterine pressure. - - SELECTED
ANSWER👀 False
T/F: The fetal spiral electrode can be placed when vaginal bleeding of
unknown origin is present. - - SELECTED ANSWER👀 False
T/F: The ultrasound transducer is usually placed on the side of the
uterus over the baby's back, as the fetal heart is heard best there. - -
SELECTED ANSWER👀 True
T/F: The spiral electrode is used to more accurately determine the
frequency, duration, and intensity of uterine contractions. - - SELECTED
ANSWER👀 False