QUESTIONS AND ANSWERS GRADED A+
✔✔Which project document is used to request clarification, supplemental information, or
approval of material substitutions? - ✔✔RFI
✔✔Comparing design documents to existing conditions, verifying parking access, and
determining the work hours are all examples of what you would learn during - ✔✔A job
start
✔✔T1 - ✔✔Layout of complete building per floor; serving zone boundaries, backbone
distribution systems, and horizontal pathways
✔✔T0 - ✔✔Campus or site plans; exterior pathways and interbuilding systems
✔✔T3 - ✔✔Communication equipment rooms; outlet/connector locations and cable ID
✔✔T4 - ✔✔Typical detail drawings; faceplate labeling; firestopping;
disability/accessibility, guidelines, and safety
✔✔T5 - ✔✔Schedules- cabling and equipment spreadsheets for cutovers
✔✔The top of an extension ladder should extend up to the work area and _________
feet above catworlks or lofts - ✔✔3 feet
✔✔Which document lists all the elements of a project including people and firms
involved, time frames, materials, and testing methods? - ✔✔Scope of work
✔✔What is dispersion? - ✔✔Widening or spreading out of the modes in a light pulse as
it progresses along the optical fiber.
✔✔Light pulses in optical fiber cables are subject to a loss in power as the light pulses
travel along the optical fiber is called - ✔✔Attenuation
✔✔What are the two most important characteristics in transporting information over
optical fiber media? - ✔✔Bandwidth
Attenuation
✔✔What is Artical 800/ Chapter 8 - ✔✔Communications Systems
✔✔The IEEE 802.11 standard covers what material? - ✔✔Wi-Fi---> WLAN
✔✔What is semi-directional? - ✔✔180-degree pattern
, ✔✔ANSI/TIA STANDARD:
Balanced twisted-pair cable - ✔✔ANSI/TIA 568.2
✔✔ANSI/TIA STANDARD:
Generic telecommunications cabling - ✔✔ANSI/TIA 568.0
✔✔ANSI/TIA STANDARD:
Structured cabling systems in commercial buildings - ✔✔ANSI/TIA 568.1
✔✔ANSI/TIA STANDARD:
Broadband Coaxial Cable - ✔✔ANSI/TIA 568.4
✔✔ANSI/TIA STANDARD:
Optical Fiber Cable - ✔✔ANSI/TIA 568.3
✔✔Pathways and spaces - ✔✔569
✔✔Administration and labeling - ✔✔606
✔✔Bonding and grounding - ✔✔607
✔✔Outside Plant (OSP) cabling - ✔✔758
✔✔Residential - ✔✔570
✔✔Data Centers - ✔✔942
✔✔Class 1 - ✔✔Single building with one equipment room
✔✔Class 2 - ✔✔Single building with multiple telecom spaces
✔✔Class 3 - ✔✔Multiple buildings on a single campus
✔✔Class 4 - ✔✔Multiple sites with multiple buildings
✔✔Labels - ✔✔Consist of face stock material