CT REGISTRY Exam Questions With
Correct Answers Already Passed 2025|
2026
What determines how much and what section of the collected raw data is used to create
an image CORRECT ANSWERS Display field of view

The "string of beads" artifact is most closely associated with which of the following?
CORRECT ANSWERS Maximum intensity projection images

A patient has a severe vagal reaction to iodinated contrast material that includes
bradycardia should be given a treatment of CORRECT ANSWERS *treatment includes
increasing blood pressure with IV fluids
*intravenous administration of atropine to block vagal stimulation of the heart

An MDCT image is reconstructed using a 512x512 matrix and a display field of view of
44 cm. If the detector collimation is set to a section width of 2.5 mm what is the volume
of each voxel CORRECT ANSWERS How to solve: The linear dimension of the pixel
must first be calculated by dividing the DFOV, in mm, by the matrix. This linear pixel
dimension is squared to yield the pixel area in mm^2. The volume of the voxel may be
calculated by multiplying the pixel area by the section width
step 1. 44 cm/ 512 =0.0859
step 2. 0.0859*2.5 mm = 0.2148
step 3. move the decimal point =2.15 mm^3

For a particular CT scanner's beam quality, the linear attenuation coefficient for water is
0.20 cm-1 and for a certain tumor is 0.21 cm-1. What is the CT number of the tumor?
CORRECT ANSWERS Equation (.21-.20/.21) × 1000= 50

A CT system measures the average linear attenuation coefficient of a voxel of tissue to
be 0.189. The linear coefficient of water for this scanner is 0.181. The CT number
assigned to the pixel representing this tissue is CORRECT ANSWERS 44 HU
use equation above

A CT scanner capable of producing an image that is a perfect reproduction of the actual
anatomic section is said to have an MTF modulator transfer function of CORRECT
ANSWERS 1

For an increase from 200 mA to 400 mA in a CT exam, the result would be to
CORRECT ANSWERS increase low contrast resolution

The major controlling factor of exam quality for coronary CTA is CORRECT ANSWERS
patients heart rate... 65-70 beats per minute yield the best results

, What is the atomic number of xenon gas? CORRECT ANSWERS 54

The exaggeration of displayed calcification within the coronary arteries during cardiac
MDCT study is referred to as CORRECT ANSWERS blooming
- the potential overestimation of vessel calcification due to partial volume artifact

a wide window setting (1500) or improving spatial resolution could help mitigate this
effect

Which of the following section widths would cause the greatest amount of partial volume
averaging

A. 1 mm
B. 3 mm
C. 5 mm
D. 10 mm CORRECT ANSWERS D. 10 mm

- Large section widths result in long voxel lengths with possibly several tissue types
accounted for within the voxel. When a CT number is assigned to the representative
pixel, the density of all the tissue types is averaged, yielding one attenuation coefficient.
Narrow section widths tend to reduce partial volume effect

What reduces partial volume effect? CORRECT ANSWERS narrow section widths

Patient is having a severe vagal reaction to contrast including brachycardia and
hypotension.. what should be done? CORRECT ANSWERS Iv fluids to raise blood
pressure
atrophine administration to block vagal stimulation of the heart.

What type of reconstruction technique was used in the first CT scanners? CORRECT
ANSWERS Iterative form of reconstruction

Sampling frequency CORRECT ANSWERS The number of views obtained by the CT
system during the data acquisition of the image.

How many samples of information comprising the raw data are there for a third-
generation, 64-row detector scanner with 850 detectors and 1700 projections acquired
during a 360 rotation CORRECT ANSWERS Solution: 850 x 1700 x 64 = 92,480,000
samples comprising raw data for this scan

What is the purpose of convolution? CORRECT ANSWERS To enhance the important
characteristics of the image before back projection is performed

In order to minimize partial volume artifacts___________ slices should be selected
CORRECT ANSWERS thinner

Document information

Uploaded on
November 8, 2025
Number of pages
9
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ElevatedExcellence
3.8
(178)
Sold
949
Followers
505
Items
18328
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions