Where there is a conflict between a general requirement and a specific requirement, the
_____ requirement shall govern. - CORRECT ANSWER Specific
102.1 General
Code
The provisions of this code shall not be mandatory for existing buildings or structures
identified and classified by the state or local jurisdiction as _____. - CORRECT
ANSWER Historic
102.6 Historic Buildings
Code
Where conflicts occur between provisions of the IMC and the referenced standards, the
provisions of _____ shall apply. - CORRECT ANSWER This Code (IMC)
102.8.1 Conflicts
Code
When authorized employees enforce this code they shall not be held _____ when acting in
good faith and without malice. - CORRECT ANSWER Liable
,103.4 Liability
Code
The code official shall have the authority to render _____ of this code. - CORRECT
ANSWER Interpretations
104.1 General
Code
Permits shall expire and become null and void if the work authorized is not commenced
within _____ days of issuance. - CORRECT ANSWER 180 days
106.4.3 Expiration
Question
How many extensions of an unexpired permit is the code official authorized to grant if
reasonable cause is demonstrated? - CORRECT ANSWER One
(Notice permit applications are permitted "one or more" extensions by Section 106.3.3)
106.4.4
Code
Underground inspections shall be made after trenches or ditches are excavated and bedded,
piping installed, and _____ backfill is put into place. - CORRECT ANSWER Before
107.2 #1 Required inspections and testing
,Code
Rough-In inspection shall be made after the roof, framing, fireblocking and bracing are in
place and all ducting and other components to be concealed are complete, and _____ to the
installation of wall or ceiling membranes. - CORRECT ANSWER Prior
107.2 #2 Required inspections and testing
Code
Final inspection shall be made upon _____ of the mechanical system. - CORRECT
ANSWER Completion
107.2 #3 Required inspections and testing
Code
Each day a code violation continues after due notice has been served shall be deemed a _____
offense. - CORRECT ANSWER Separate
108.4 Violation penalties
Code
The code official shall have the authority to order _____ of energy sources supplied to a
building, structure or mechanical system regulated by this code, when it is determined that
the mechanical system or any portion thereof has become hazardous or unsafe. - CORRECT
ANSWER Disconnection
108.7.2 Authority to order disconnection of energy sources.
, Definition
The minimum distance through air measured between the heat-producing surface of the
mechanical appliance, device or equipment and the surface of the combustible material or
assembly. - CORRECT ANSWER Clearance
202 General Definitions
Definition
The treatment of air so as to control simultaneously the temperature, humidity, cleanness and
distribution of the air to meet the requirements of a conditioned space. - CORRECT
ANSWER Air Conditioning
202 General Definitions
Definition
A system that consists of heat exchangers, blowers, filters, supply, exhaust and return ducts,
and shall include any apparatus installed in connection therewith. - CORRECT
ANSWER Air-conditioning System
202 General Definitions
Definition
Air removed from an approved conditioned space or location and recirculated or exhausted. -
CORRECT ANSWER Return Air
202 General Definitions