High priming water levels can adversely affect the operation of supervisory air.

What is not a step in testing the water level? - Correct answer-Close the priming

level test valve before air discharges

The _____ valve shall be supervised closed in the pipeline to the hose valve header

- Correct answer-control

A diesel fuel storage tank is required to always be a minimum of __ full. - Correct

answer-2/3

A fire pump controller shall be in a fully functional state within ___ seconds of AC

power available. - Correct answer-10

The standpipe system demand shall include 500 gpm for the first standpipe and

___ gpm for each additional standpipe until the total system demand is

simultaneously met. - Correct answer-250




©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

,Water motor gongs and pressure switch alarm devices shall be inspected: - Correct

answer-quarterly

A temporary standpipe used during construction must be at least ___ in diameter -

Correct answer-4 inches

Blue color coding on a sprinkler indicates it has a temperature rating between

_____. - Correct answer-250 - 300 degrees F

When swapping out pressure gauges, it is important to verify the arrow on the 3-

way valve is pointed in the proper direction before removing the gauge and once

the gauge is removed, the 3-way valve must be flushed adequately so any debris

that may have accumulated does not end up in the new gauge. - Correct answer-

True

According to NFPA 20, a _____ refill valve shall be used for each water supply

tank used for fire protection. - Correct answer-automatic

All sprinkler pressure-reducing valves shall be inspected qurterly to verify the

valves are in the following condition except: - Correct answer-in the closed

position

Which type of pipe is not approved for standpipes - Correct answer-CPVC



©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

, Foam concentrate strainers shall be inspected: - Correct answer-quarterly

A fire pump water supply must be ___. - Correct answer-Adequate and dependable

The shut-off head shall not exceed ___ of rated head for any pump. - Correct

answer-140%

The top hose outlet in a buuilding under construction must be maintained within

_____ floors of the highest forms, staging and similar combustibles at all times. -

Correct answer-one

The drain riser shall be equipped with tees that are of the same size as the

discharge outlets of the ___ devices to be tested and shall be located at least every

other floor. - Correct answer-pressure regulating

What is the minimum suction pressure required at the pump suction flange when a

suction tank is installed at or above the base of the fire pump running at 150%

capacity? - Correct answer--3

What type of standpipe is not required to be hydrostatically tested at 200 psi or 50

psi in excess of 150 psi? - Correct answer-manual standpipe

When soldering copper, flux should be applied to ___. - Correct answer-the inside

of the fitting and the outside of the tube


©COPYRIGHT 2025, ALL RIGHTS RESERVED 3

Document information

Uploaded on
November 3, 2025
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJessica
3.3
(3)
Sold
21
Followers
0
Items
5305
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions