Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 7 pages
Exam (elaborations)

Z-89 Non-Fire Quick 50 Question Practice Test questions and answers

Document preview thumbnail
Preview 2 out of 7 pages

Most common elements that may change the sensitivity of a smoke detector include which of the following? A. Dust B. Dirt C. Foreign materials Detectors found to have a sensitivity of ___________ outside the listed & marked sensitivity range shall be cleaned, recalibrated / replaced. A. 0.25%

Content preview

Z-89 Non-Fire Quick 50 Question
Practice Test questions and answers
Most common elements that may change the sensitivity of a smoke detector include
which of the following? ✔✔A. Dust
B. Dirt
C. Foreign materials

Detectors found to have a sensitivity of ___________ outside the listed & marked
sensitivity range shall be cleaned, recalibrated / replaced. ✔✔A. 0.25%

After the second required calibration test, if sensitivity tests indicate that the device has
remained within its listed & marked sensitivity range ( / 4 % obscuration light gray
smoke, if not marked), the length of time between calibration tests shall be permitted to
be extended to a maximum of how many years? ✔✔5 years

Recalibration regarding smoke detectors are required to be performed by an
__________ Certificate of Fitness holder. ✔✔S-97 / S-98 C of F holder

All smoke detectors must be tested for sensitivity w/in __________ after they have been
installed. This is done to confirm if it is w/in its listed sensitivity range. ✔✔One year

The acceptable methods to TEST the sensitivity of smoke detectors include which of the
following? ✔✔A. Manufacturer's calibrated sensitivity test instrument
B. Listed control equipment arranged for the purpose
C. Calibrated test method

Records of all system inspections, tests, servicing & other maintenance required by the
NYC Fire Code, shall be maintained on the premises for a minimum of how many
years? ✔✔3 years

The _____ of any premises monitored by a defined fire alarm system shall be
responsible for the detection maintenance required by the NYC Fire Code & the smoke
detector cleaning & testing. ✔✔Building owner

The responsibility of maintaining the Alarm Log Book belongs to which of the following
individuals? ✔✔F-89 Fire Life Safety Director

In buildings not requiring a Fire Life Safety Director, a person designated by the
________ shall be responsible to make all log book entries. ✔✔Building owner

, The Alarm Log Book shall be maintained where on the premises as required by the
FDNY? ✔✔Fire Alarm Control Panel

The Alarm Log Book shall be divided into separate sections as set forth in the NYC Fire
Code. It should include which of the following? ✔✔A. Daily entries
B. System off-line entries
C. Activated alarm entries

A smoke detector maintenance log book shall be maintained on the premises in the
office of the Fire Safety Director, / in buildings not requiring a Fire Life Safety Director, in
the building Superintendent's office. Such log book shall state which of the following?
✔✔A. Total number of smoke detectors on the premises.
C. List each smoke detector by location.

According to the NYC Fire Code, a(an) _________ is considered to be an alarm signal
transmitted by a fire alarm system which functioned as designed, but for which a
department response proved unnecessary. ✔✔Unwarranted alarm

Unwarranted alarms can occur for several reasons. They can transpire as a result of:
✔✔A. Lack of maintenance
B. Improper detector placement
C. Improper detector settings

Who is responsible for preventing the transmission of unnecessary / unwarranted
alarms, & shall. be liable for any violation of the NYC Fire Code? ✔✔A. Building owner

It shall be unlawful to transmit __________ / more unnecessary / unwarranted alarms in
any (3) three-month period. ✔✔Two

The owner of any premises from which a second unnecessary / unwarranted alarm is
transmitted in any _______ period will be subject to issuance of a Notice of Violation.
✔✔Three-month

Whether a building is required to be provided w/ a fire alarm system / not, the type of
fire alarm system required & the standard for such installations are set forth in the
________. ✔✔NYC Building Code

Since smoke detectors rely on the _________ to convey smoke & hot combustion to the
detector, any object that slows down the flow may affect the performance of the
detector. ✔✔Ceiling jetA _________ is any system arranged to monitor & alert the
status of fire alarm / supervisory signal-initiating devices. ✔✔Fire Alarm System

The purpose of a fire alarm system shall be primarily to perform which of the following?
✔✔A. Provide notification of fire alarm, supervisory, & trouble conditions
B. Alert the occupants of the condition

Document information

Uploaded on
October 24, 2025
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
0
Followers
0
Items
212
Last sold
-



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions