AHIT Final Exam || with Complete Questions And
100% Confirmed Answers.
When should the home inspector not remove the cover (dead-front) to the main
panel? - (ANSWERS)if the inspector gets a shock upon touching it
What is a subpanel? - (ANSWERS)a panel that adds more circuits to the service
When inspecting the fuses or breakers, the home inspector should _____. -
(ANSWERS)compare amperage rating of fuse or breaker to connected branch
wiring
Where is the home inspector likely to find aluminum branch circuit wiring? -
(ANSWERS)in homes built during the mid-1960s to mid-1970s
***Electrical receptacles should be present _____.*** - (ANSWERS)every 12'
along interior walls
According to most standards, the home inspector is required to _____. -
(ANSWERS)operate all gfcis
***What is a split receptacle?*** - (ANSWERS)one that has a complete circuit for
each half of the receptacle
How do the standards describe the inspection of a home's electrical system? -
(ANSWERS)as a visual inspection
What is resistance? - (ANSWERS)opposition of a material to the flow of electricity
What is the measure for electromotive force? - (ANSWERS)volts
***What is the most highly recommended method of repairing aluminum branch
circuit wiring?*** - (ANSWERS)using COPALUM crimp connectors to bond
,AHIT Final Exam || with Complete Questions And
100% Confirmed Answers.
copper to the aluminum wiring at every connection and splice
What wire gauge should the service conductors be for a 100-amp electrical service?
- (ANSWERS)#4 copper or #2 aluminum
What can be the cause of driveway upheaval? - (ANSWERS)tree roots
Which of the following should be reported as a safety hazard? -
(ANSWERS)balusters too far apart
Why should sources of ignition be raised 18" off the floor? - (ANSWERS)it keeps
the ignition sources away from gasoline vapors
When the solvent in paint evaporates too quickly, what can be the result? -
(ANSWERS)alligatoring
What would not be a cause of a sliding glass door rubbing during operation? -
(ANSWERS)a leaking seal in the window
What is the definition of a porch? - (ANSWERS)a roofed extension of the house
What is the proper pitch for a patio? - (ANSWERS)pitched away from the house
The most common retaining wall failure is caused by _____. -
(ANSWERS)inadequate drainage
The main problem with stucco is that it _____. - (ANSWERS)tends to crack
How should the corner moldings on aluminum siding be installed? -
(ANSWERS)the upper molding overlapping the one below
100% Confirmed Answers.
When should the home inspector not remove the cover (dead-front) to the main
panel? - (ANSWERS)if the inspector gets a shock upon touching it
What is a subpanel? - (ANSWERS)a panel that adds more circuits to the service
When inspecting the fuses or breakers, the home inspector should _____. -
(ANSWERS)compare amperage rating of fuse or breaker to connected branch
wiring
Where is the home inspector likely to find aluminum branch circuit wiring? -
(ANSWERS)in homes built during the mid-1960s to mid-1970s
***Electrical receptacles should be present _____.*** - (ANSWERS)every 12'
along interior walls
According to most standards, the home inspector is required to _____. -
(ANSWERS)operate all gfcis
***What is a split receptacle?*** - (ANSWERS)one that has a complete circuit for
each half of the receptacle
How do the standards describe the inspection of a home's electrical system? -
(ANSWERS)as a visual inspection
What is resistance? - (ANSWERS)opposition of a material to the flow of electricity
What is the measure for electromotive force? - (ANSWERS)volts
***What is the most highly recommended method of repairing aluminum branch
circuit wiring?*** - (ANSWERS)using COPALUM crimp connectors to bond
,AHIT Final Exam || with Complete Questions And
100% Confirmed Answers.
copper to the aluminum wiring at every connection and splice
What wire gauge should the service conductors be for a 100-amp electrical service?
- (ANSWERS)#4 copper or #2 aluminum
What can be the cause of driveway upheaval? - (ANSWERS)tree roots
Which of the following should be reported as a safety hazard? -
(ANSWERS)balusters too far apart
Why should sources of ignition be raised 18" off the floor? - (ANSWERS)it keeps
the ignition sources away from gasoline vapors
When the solvent in paint evaporates too quickly, what can be the result? -
(ANSWERS)alligatoring
What would not be a cause of a sliding glass door rubbing during operation? -
(ANSWERS)a leaking seal in the window
What is the definition of a porch? - (ANSWERS)a roofed extension of the house
What is the proper pitch for a patio? - (ANSWERS)pitched away from the house
The most common retaining wall failure is caused by _____. -
(ANSWERS)inadequate drainage
The main problem with stucco is that it _____. - (ANSWERS)tends to crack
How should the corner moldings on aluminum siding be installed? -
(ANSWERS)the upper molding overlapping the one below