Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

Florida Wastewater Operator class B certification exam Questions With Complete Solutions Rated A+

Document preview thumbnail
Preview 2 out of 8 pages

A common remedy for activated sludge system problems is to increase the waste activated sludge flow rate, when would an increase of WAS rate not be correct? - CORRECT ANSWER-When straggler Floc is present in clarifier and settleometer solve MCRT: Flow: 3.6mgd Basin volume: 5.0mg MLSS:2350mg/l WAS ss:4800mg/l WAS flow: 150000gpd Eff tss: 15mg/l - CORRECT ANSWER-15 days There are high suspended solids in the water applied to the filters due to bulking sludge in the secondary clarifiers. Polymer is used as a filter aid chemical, but the effluent ability is worsening. What is the best method to correct the filter problem? - CORRECT ANSWER-Run jar tests to determine best Polymer dosage An advantage of a continuous backwash, up flow, deep bed sand filters is? - CORRECT ANSWER-Filters do not need to be taken out of service for backwashing The aeration tank dissolved oxygen has been running normal, 1.5 to 2.0 mg/L the whole month. Today's D.O. reading has spiked to nearly 6.0 mg/L in the aeration tank and the clarifier and plant effluent or cloudy. What is the most likely cause of the rise in D.O.? - CORRECT ANSWER-A toxic shock load of cyanide has entered the plant

Content preview

Florida Wastewater Operator class B
certification exam Questions With
Complete Solutions Rated A+

A common remedy for activated sludge system problems is to increase the waste
activated sludge flow rate, when would an increase of WAS rate not be correct? -
CORRECT ANSWER-When straggler Floc is present in clarifier and settleometer



solve MCRT:

Flow: 3.6mgd

Basin volume: 5.0mg

MLSS:2350mg/l

WAS ss:4800mg/l

WAS flow: 150000gpd

Eff tss: 15mg/l - CORRECT ANSWER-15 days



There are high suspended solids in the water applied to the filters due to bulking sludge
in the secondary clarifiers.

Polymer is used as a filter aid chemical, but the effluent ability is worsening.

What is the best method to correct the filter problem? - CORRECT ANSWER-Run jar
tests to determine best Polymer dosage



An advantage of a continuous backwash, up flow, deep bed sand filters is? - CORRECT
ANSWER-Filters do not need to be taken out of service for backwashing



The aeration tank dissolved oxygen has been running normal, 1.5 to 2.0 mg/L the whole
month.

, Today's D.O. reading has spiked to nearly 6.0 mg/L in the aeration tank and the clarifier
and plant effluent or cloudy.

What is the most likely cause of the rise in D.O.? - CORRECT ANSWER-A toxic shock
load of cyanide has entered the plant



Plant fecal coliform counts do not meet state standards.

The chlorine supply is not the problem and there is adequate vacuum and chlorine feed
the chlorine contacting has no solids build up and the effluent flow is below design.

What is the most likely cause of the poor fecal coliform kill? - CORRECT ANSWER-
High chlorine demand from excessive nitrite in effluent



The point, location or structure where wastewater discharges from a sewer, drain or
other conduit is called what? - CORRECT ANSWER-Outfall



The chlorine residual is falling An inspection of the 150lb cylinder and chlorine feed
equipment shows ice forming on the chlorine regulator and feed lines. The best method
to fix the falling chlorine residual is? - CORRECT ANSWER-Put another chlorine
cylinder online



Caution must be used when adding caustic chemical to a digester.

Lime can combine with carbon dioxide in the digester to form what problem? -
CORRECT ANSWER-A dangerous vacuum



How many gallons will the single piston, reciprocating sludge pump discharge per
minute If the piston bore (diameter) is 6 inches and the stroke length is 11 inches? The
pump runs at 99 revolutions per minute. - CORRECT ANSWER-134gpm



The volatile acid to alkalinity ratio of a properly operating anaerobic digester is -
CORRECT ANSWER-0.1 parts acid to one part alkalinity (0.1 : 1.0)

Document information

Uploaded on
October 22, 2025
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
remojudytask
3.2
(26)
Sold
94
Followers
30
Items
3119
Last sold
1 month ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions