A |flow |of |60 |gph |is |equal |to?
| a. |1 |mgd
| b. |1mg/L
| c. |10 |gpm
| d. |1 |gpm |- |CORRECT |ANSWER✔✔-d. |1 |gpm |(60 |gph |/ |60 |min/hr |)
The |slope |of |a |sewer |is |measured |by
| a. |The |difference |from |the |crown |to |the |invert
| b. |The |difference |in |invert |elevations |over |the |length
| of |the |pipe
| c. |Using |the |diameter |of |the |pipe
|d. |Only |entering |the |manhole |- |CORRECT |ANSWER✔✔-b. |The |difference |in |invert |elevation |
over |the |length |
| of |the |pipe
An |air |gap |can |be |used |to
| a. |Clean |sewer |blockages |caused |by |grease
| b. |Let |air |into |manholes
,| c. |Prevent |backflow |of |wastewater |into |a |drinking
| water |supply
d. |Test |for |oxygen |deficiency |in |manholes |- |CORRECT |ANSWER✔✔-c. |Prevent |backflow |of |
|
wastewater |into |a |drinking |
| water |supply.
A |cross |connection |is
| a. |Cast |Iron |pipe |connected |to |concrete |pipe
| b. |Steel |pipe |connected |to |asbestos |pipe
| c. |Potable |(Drinkable) |water |pipe |connected |to |a |supply |
| of |questionable |origin
d. |Lateral |line |connected |to |an |interceptor |- |CORRECT |ANSWER✔✔-c. |Potable |(Drinkable) |
|
water |pipe |connected |to |a |
| supply |of |questionable |origin
Wastewater |carried |in |a |collection |system |may |come |from
| a. |Digester |supernatant
| b. |Exfiltration
| c. |Primary |settling |tank
| d. |Inflow |- |CORRECT |ANSWER✔✔-d. |Inflow
When |using |any |hydraulic |sewer |cleaning |method, |care |must |be |taken |by |the |operator
| a. |To |always |plug |the |downstream |manhole
| b. |Not |to |cause |flooding |in |homes |and |businesses
,| c. |To |prevent |any |sir |gap |from |occurring
| d. |To |throttle |flows |from |the |hydrants |by |using |
|the |hydrant |valve |only |- |CORRECT |ANSWER✔✔-b. |Not |to |cause |flooding |in |homes |and |
businesses
Disease |producing |bacteria |are |called
| a. |Saprophytic
| b. |Facultative
| c. |Pathogenic
| d. |Parasitic |- |CORRECT |ANSWER✔✔-c. |Pathogenic
A |manhole |with |a |center |grating |is |normally |used |for
| a. |Venting
| b. |Storm |sewers
| c. |Sanitary |sewers
| d. |None |of |the |above |- |CORRECT |ANSWER✔✔-b. |Storm |sewers
A |pig |would |be |used |as |________________in |a |force |
main.
| a. |A |reamer
| b. |A |stopper
| c. |A |Float
| d. |A |tell |tale |- |CORRECT |ANSWER✔✔-a. |A |reamer
, A |minimum |scouring |velocity |of |2 |ft/sec |in |sewers |is |
| necessary |so |that
| a. |Flow |velocities |can |be |estimated |between |manholes
| b. |Roots |won't |grow |in |sewers
| c. |Sewer |pipes |won't |become |eroded |on |the |bottom
| d. |Solids |won't |build |up |in |a |sewer |and |
|reduce |flow |capacity |- |CORRECT |ANSWER✔✔-d. |Solids |won't |build |up |in |a |sewer |and |reduce |
flow |capacity
A |cross |connection |is |best |defined |as |
| a. |Ground |water |entering |a |gravity |sewer |through
| cracks |in |the |piping
| b. |A |lateral |line |connected |to |the |main |illegally
| c. |Storm |drainage |piped |into |a |domestic |
| collection |system
| d. |A |potable |water |supply |connected |to |a |potential |source |
| of |pollution. |- |CORRECT |ANSWER✔✔-d. |A |potable |water |supply |connected |to |a |potential |
| source |of |pollution.
When |dealing |with |collection |systems, |I |& |I |refers |to
| a. |Inflow |and |inspection
| b. |inspection |and |information
C Exam Questions With Correct Answers
A |flow |of |60 |gph |is |equal |to?
| a. |1 |mgd
| b. |1mg/L
| c. |10 |gpm
| d. |1 |gpm |- |CORRECT |ANSWER✔✔-d. |1 |gpm |(60 |gph |/ |60 |min/hr |)
The |slope |of |a |sewer |is |measured |by
| a. |The |difference |from |the |crown |to |the |invert
| b. |The |difference |in |invert |elevations |over |the |length
| of |the |pipe
| c. |Using |the |diameter |of |the |pipe
|d. |Only |entering |the |manhole |- |CORRECT |ANSWER✔✔-b. |The |difference |in |invert |elevation |
over |the |length |
| of |the |pipe
An |air |gap |can |be |used |to
| a. |Clean |sewer |blockages |caused |by |grease
| b. |Let |air |into |manholes
,| c. |Prevent |backflow |of |wastewater |into |a |drinking
| water |supply
d. |Test |for |oxygen |deficiency |in |manholes |- |CORRECT |ANSWER✔✔-c. |Prevent |backflow |of |
|
wastewater |into |a |drinking |
| water |supply.
A |cross |connection |is
| a. |Cast |Iron |pipe |connected |to |concrete |pipe
| b. |Steel |pipe |connected |to |asbestos |pipe
| c. |Potable |(Drinkable) |water |pipe |connected |to |a |supply |
| of |questionable |origin
d. |Lateral |line |connected |to |an |interceptor |- |CORRECT |ANSWER✔✔-c. |Potable |(Drinkable) |
|
water |pipe |connected |to |a |
| supply |of |questionable |origin
Wastewater |carried |in |a |collection |system |may |come |from
| a. |Digester |supernatant
| b. |Exfiltration
| c. |Primary |settling |tank
| d. |Inflow |- |CORRECT |ANSWER✔✔-d. |Inflow
When |using |any |hydraulic |sewer |cleaning |method, |care |must |be |taken |by |the |operator
| a. |To |always |plug |the |downstream |manhole
| b. |Not |to |cause |flooding |in |homes |and |businesses
,| c. |To |prevent |any |sir |gap |from |occurring
| d. |To |throttle |flows |from |the |hydrants |by |using |
|the |hydrant |valve |only |- |CORRECT |ANSWER✔✔-b. |Not |to |cause |flooding |in |homes |and |
businesses
Disease |producing |bacteria |are |called
| a. |Saprophytic
| b. |Facultative
| c. |Pathogenic
| d. |Parasitic |- |CORRECT |ANSWER✔✔-c. |Pathogenic
A |manhole |with |a |center |grating |is |normally |used |for
| a. |Venting
| b. |Storm |sewers
| c. |Sanitary |sewers
| d. |None |of |the |above |- |CORRECT |ANSWER✔✔-b. |Storm |sewers
A |pig |would |be |used |as |________________in |a |force |
main.
| a. |A |reamer
| b. |A |stopper
| c. |A |Float
| d. |A |tell |tale |- |CORRECT |ANSWER✔✔-a. |A |reamer
, A |minimum |scouring |velocity |of |2 |ft/sec |in |sewers |is |
| necessary |so |that
| a. |Flow |velocities |can |be |estimated |between |manholes
| b. |Roots |won't |grow |in |sewers
| c. |Sewer |pipes |won't |become |eroded |on |the |bottom
| d. |Solids |won't |build |up |in |a |sewer |and |
|reduce |flow |capacity |- |CORRECT |ANSWER✔✔-d. |Solids |won't |build |up |in |a |sewer |and |reduce |
flow |capacity
A |cross |connection |is |best |defined |as |
| a. |Ground |water |entering |a |gravity |sewer |through
| cracks |in |the |piping
| b. |A |lateral |line |connected |to |the |main |illegally
| c. |Storm |drainage |piped |into |a |domestic |
| collection |system
| d. |A |potable |water |supply |connected |to |a |potential |source |
| of |pollution. |- |CORRECT |ANSWER✔✔-d. |A |potable |water |supply |connected |to |a |potential |
| source |of |pollution.
When |dealing |with |collection |systems, |I |& |I |refers |to
| a. |Inflow |and |inspection
| b. |inspection |and |information