An "A" base meter has terminals located on the backside of the meter. Answer: : False (A-base terminals are on the bottom) S or "Socket" type meters are on the back side of the meter. Answer: : True The resistor is the part of a watt-hour meter that introduces a retarding effect on the disk. Answer: : False (Retarding magnet introduces retarding effect) The basic principles of operation of the electro-mechanical watt-hour meter introduced around 1900 are completely different from those of today's electro-mechanical meters. Answer: : False The interaction of the current and potential coil fluxes and the induced eddy current fluxes in a meter disk produce disk rotation. Answer: : True The designation of "CL 100" on a meter nameplate indicates that the meter is transformer rated and will have instrument transformers associated with it. Answer: : False The voltage rating on a meter nameplate indicates the voltage rating of the meter's potential coil or coils. Answer: : Tr

Content preview

EEE 334 – Lab 2 Metering Overview |
Complete Study Material.
An "A" base meter has terminals located on the backside of the meter.
Answer>>>: : False (A-base terminals are on the bottom)


S or "Socket" type meters are on the back side of the meter.
Answer>>>: : True


The resistor is the part of a watt-hour meter that introduces a retarding effect on
the disk.
Answer>>>: : False (Retarding magnet introduces retarding effect)


The basic principles of operation of the electro-mechanical watt-hour meter
introduced around 1900 are completely different from those of today's electro-
mechanical meters.
Answer>>>: : False


The interaction of the current and potential coil fluxes and the induced eddy
current fluxes in a meter disk produce disk rotation.
Answer>>>: : True


The designation of "CL 100" on a meter nameplate indicates that the meter is
transformer rated and will have instrument transformers associated with it.
Answer>>>: : False


The voltage rating on a meter nameplate indicates the voltage rating of the
meter's potential coil or coils.
Answer>>>: : True
Page 1 of 38

,EEE 334 – Lab 2 Metering Overview |
Complete Study Material.

The rating in volts of a meter's current coils is called its Class.
Answer>>>: : False (It is called Voltage rating)


All poly-phase meters have two or more stators.
Answer>>>: : True


The test switch used in conjunction with a transformer-rated meter is used to
de-energize the customer's loads while the meter is being tested.
Answer>>>: : False (It isolates the meter but does not affect customer
load)


Transformer-rated meters are used when voltage and/or current exceeds the
ratings of self-contained meters.
Answer>>>: : True


When a comparison test is made on a watt-hour meter, the currents through the
meter, the test standard, and the phantom load are all the same.
Answer>>>: : True


Since company meter seals that have been tampered with can usually be
discovered visually, it is not necessary to pull on a seal to see if it is in its proper
condition.
Answer>>>: : False


Multiple Choice / Select All That Apply Questions
Page 2 of 38

,EEE 334 – Lab 2 Metering Overview |
Complete Study Material.

Which of the following are the basic parts of a watt-hour meter?
Answer>>>: :


COVER


BASE


STATOR


RETARDING MAGNET


ROTOR ASSEMBLY or DISK


REGISTER


Which of the following are types of watt-hour meter bases?
Answer>>>: :


"S" type


"A" type




Page 3 of 38

, EEE 334 – Lab 2 Metering Overview |
Complete Study Material.
When the voltage requirements of a customer exceed the rating of a self-
contained meter, which instrument transformers are needed in conjunction with
a transformer-rated meter?
Answer>>>: :


Voltage transformers "VT's"


Current transformers "CT's"


Which of the following is an example of a self-contained meter class?
Answer>>>: : Class 200


As-found accuracy tests on self-contained meters are typically made at what two
power levels?
Answer>>>: :


Light load, or 10% of rated test amps


Full load, or rated test amps


Which of the following is used in comparison testing to supply a regulated
current during the test?
Answer>>>: : A phantom load




Page 4 of 38

Document information

Uploaded on
October 12, 2025
Number of pages
38
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
4
Followers
0
Items
1105
Last sold
8 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions