Pass Verified 2025 New Update
the recovery process on an R-12 or R-134a A/C system should continue until a stable
vacuum held by the system for - Answer- 2 minutes
technician a says that the refrigerant container should be placed in a cooler storage
area before use
technician b says that the vapor in the container should be slowly vented into a
refrigerant handling unit - Answer- b only
the ozone layer filters out most of the suns harmful - Answer- ultraviolet radiation
the reduction of ozone in the stratosphere could cause - Answer- an increase in skin
cancer and eye cataracts
technician a says that sunlight striking CFC molecules can cause chlorine to be
released
technician b says that chlorine atoms react with ozone to produce chlorine monoxide -
Answer- both a and b
R 134a refrigerant must be reclaimed to meet which of these purity standards - Answer-
j2099
if the required charge level of refrigerant for MVAC system is 40 ounces which of these
is correct charge level measured in pounds - Answer- #number of ounces /16 2.50
technician a says that recover/recycling/recharging equipment for R-1234yf refrigerant
requires integration with a refrigerant identifier
technician b says that recovery/recycling/recharging equipment for R-1234yf refrigerant
uses a 17mm O.D quick coupler on the low side service hose - Answer- a only
which of these identifies a cylinder of R1234yf - Answer- white with red band
a container of recycled R-134a refrigerant that is being tested for non-condensable
gases (air) should be - Answer- stored out of direct sunlight
the epa allows the use of R-134a recovery only provided that the - Answer- equipment
meets j2810 standards