• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 1 out of 3 pages
Exam (elaborations)

Refrigerant and recovery Exam A+ Pass Verified 2025 New Update

Document preview thumbnail
Preview 1 out of 3 pages

Refrigerant and recovery the recovery process on an R-12 or R-134a A/C system should continue until a stable vacuum held by the system for - Answer- 2 minutes technician a says that the refrigerant container should be placed in a cooler storage area before use technician b says that the vapor in the container should be slowly vented into a refrigerant handling unit - Answer- b only the ozone layer filters out most of the suns harmful - Answer- ultraviolet radiation the reduction of ozone in the stratosphere could cause - Answer- an increase in skin cancer and eye cataracts technician a says that sunlight striking CFC molecules can cause chlorine to be released technician b says that chlorine atoms react with ozone to produce chlorine monoxide - Answer- both a and b R 134a refrigerant must be reclaimed to meet which of these purity standards - Answer- j2099 if the required charge level of refrigerant for MVAC system is 40 ounces which of these is correct charge level measured in pounds - Answer- #number of ounces /16 2.50 technician a says that recover/recycling/recharging equipment for R-1234yf refrigerant requires integration with a refrigerant identifier technician b says that recovery/recycling/recharging equipment for R-1234yf refrigerant uses a 17mm O.D quick coupler on the low side service hose - Answer- a only which of these identifies a cylinder of R1234yf - Answer- white with red band a container of recycled R-134a refrigerant that is being tested for non-condensable gases (air) should be - Answer- stored out of direct sunlight the epa allows the use of R-134a recovery only provided that the - Answer- equipment meets j2810 standards technician a says that it is OK to use a disposable refrigerant tank to store recycled refrigerant technician b says that it is ok to fill an approved refrigerant tank to 70% of its gross weight rating who was right - Answer- neither before a container of a stored recycled refrigerant is used the container must be checked for - Answer- non condensable gases recovery equipment for R-134a refrigerant must meet standards set by - Answer- SAE alternative refrigerants use a unique set of service fittings that - Answer- prevent accidental mixing of refrigerants technician a says that R-744 refrigerant is accepted by the EPA as an alternative for retrofit technician b says that R-134a refrigerant is accepted by the EPA as an alternative for retrofit - Answer- b only SAE standards J2099 specifies that the maximum level of non-condensable gases in recycled R-134a should not exceed - Answer- 1.5% by volume when service equipment hoses with manual shutoff valves are not connected to an A/C system, the valves should be in the - Answer- closed position technician a says that R-1234yf may be used to retrofit an R-134a system technician B says that R-1234yf is an ozone depleting gas - Answer- neither a technician who successfully completes the training and certification in an EPA approved section 609 program can legally service MVAC systems that uses any of these refrigerants EXCEPT - Answer- R-22

Content preview

Refrigerant and recovery Exam A+
Pass Verified 2025 New Update
the recovery process on an R-12 or R-134a A/C system should continue until a stable
vacuum held by the system for - Answer- 2 minutes

technician a says that the refrigerant container should be placed in a cooler storage
area before use

technician b says that the vapor in the container should be slowly vented into a
refrigerant handling unit - Answer- b only

the ozone layer filters out most of the suns harmful - Answer- ultraviolet radiation

the reduction of ozone in the stratosphere could cause - Answer- an increase in skin
cancer and eye cataracts

technician a says that sunlight striking CFC molecules can cause chlorine to be
released

technician b says that chlorine atoms react with ozone to produce chlorine monoxide -
Answer- both a and b

R 134a refrigerant must be reclaimed to meet which of these purity standards - Answer-
j2099

if the required charge level of refrigerant for MVAC system is 40 ounces which of these
is correct charge level measured in pounds - Answer- #number of ounces /16 2.50

technician a says that recover/recycling/recharging equipment for R-1234yf refrigerant
requires integration with a refrigerant identifier

technician b says that recovery/recycling/recharging equipment for R-1234yf refrigerant
uses a 17mm O.D quick coupler on the low side service hose - Answer- a only

which of these identifies a cylinder of R1234yf - Answer- white with red band

a container of recycled R-134a refrigerant that is being tested for non-condensable
gases (air) should be - Answer- stored out of direct sunlight

the epa allows the use of R-134a recovery only provided that the - Answer- equipment
meets j2810 standards

Document information

Uploaded on
September 24, 2025
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ScholarExams
3.8
(75)
Sold
400
Followers
186
Items
11787
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions