100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Fire Alarm Level II Actual Exam Preparation Newest 2025/2026 Complete 200 Questions And Correct Answers (Verified Answers)|Already Graded A+

Rating
-
Sold
-
Pages
87
Grade
A+
Uploaded on
18-09-2025
Written in
2025/2026

Fire Alarm Level II Actual Exam Preparation Newest 2025/2026 Complete 200 Questions And Correct Answers (Verified Answers)|Already Graded A+

Institution
Fire Alarm
Course
Fire Alarm











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Fire Alarm
Course
Fire Alarm

Document information

Uploaded on
September 18, 2025
Number of pages
87
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1|Page


Fire Alarm Level II Actual Exam Preparation Newest 2025/2026
Complete 200 Questions And Correct Answers (Verified
Answers)|Already Graded A+


Which of the following descriptions would NOT be considered a qualified system
designer?
A. A person who is certified by a state authority.
B. A person who is certified by an internationally recognized certification
organization.
C. A person who is factory trained and certified for fire alarm system design.
D. A person or organization who is approved by the AHJ to design fire alarm
systems. - CORRECT ANSWER=B


If you try to drive a grounding rod and you hit solid rock, you are permitted to bury
the grounding rod in a trench that is at LEAST____deep. - CORRECT
ANSWER=30"


When a raceway is run from the interior to the exterior of a building, the raceway
shall_______.


A. be rigid metal conduit (RMC)
B. be rigid polyvinyl chloride conduit (PVC)
C. be sealed with an approved material
D. have an explosion-proof seal - CORRECT ANSWER=C


When installing smoke detectors in rooms with HVAC diffusers, how far are the
detectors required to be away from the venting? - CORRECT ANSWER=3 feet

,2|Page




Unless otherwise identified, conductors of sizes 14 AWG through 1AWG shall be
rated at_______ - CORRECT ANSWER=60 degrees C


When installing electrical metallic tubing (EMT), the run of tubing is required to
be securely fastened at LEAST every_______(Disregard exceptions) - CORRECT
ANSWER=10 feet


A coded supervisory signal shall be permitted to consist of ___________ rounds of
the number transmitted to indicate a supervisory off-normal condition. -
CORRECT ANSWER=2


Smoke detectors shall not be installed if the temperature is above _____________
degrees F - CORRECT ANSWER=100


A fire alarm system was installed in a protected premises. The FAS is connected to
a supervising station and consists of waterflow detection. Which other device shall
be installed on the protected premises? - CORRECT ANSWER=Manual pull
station


In a protected premises, any trouble signals and its return to normal shall be
displayed within __________ at the FACP. - CORRECT ANSWER=200 seconds


When is a manual fire alarm system NOT required in Group E occupancies?
A. When an automatic sprinkler system is already installed
B. When an automatic fire alarm system is already installed
C. When the occupant load is 50 or less

,3|Page


D. All of the above - CORRECT ANSWER=C


An R-2 apartment building with 20 dwelling units which of the following is true
according to the IBC?
A. a manual fire alarm system that activates the occupant notification is required
B. An automatic fire alarm system with no occupant notification is required
C. Only smoke alarms in each apartment is required for this apartment building
D. No fire alarm system is required for this building - CORRECT ANSWER=A


Two resistors are connected in SERIES; R1 = 40 Ohms, R2 = 10 Ohms, what is the
Resistance of the circuit? - CORRECT ANSWER=50 Ohms


Which of the following circuit pathway designations has a fail-safe operation and
no fault is annunciated? - CORRECT ANSWER=Class D


True/False: Class X is redundant? - CORRECT ANSWER=True


After a loss of primary power, textual visible appliances shall have sufficient
secondary power to operate for a minimum of _____________ of continuous
display time during an emergency event. - CORRECT ANSWER=2 hours


Combination manual fire alarm boxes and __________ shall be permitted?
A. horn/strobes
B. smoke detectors
C. guard's signaling stations
D. none of the above - CORRECT ANSWER=C

, 4|Page




For Groups A-1, A-3, A-4 an automatic sprinkler system is required if fire area is
greater than _______________ sq ft - CORRECT ANSWER=12,000 sq ft


For Group A-2 an automatic sprinkler system is required if fire area is greater than
____________________ sq ft - CORRECT ANSWER=5,000 sq ft


For Groups A-1, A-2, A-3 an automatic sprinkler system is required if occupancy is
greater than _____________ people - CORRECT ANSWER=300


For Groups S-1, sprinklers are required in areas greater than __________ sq ft -
CORRECT ANSWER=12,000 sq ft


For Groups S-1 that houses commercial motor vehicles sprinklers are required in
areas greater than ________________ sq ft - CORRECT ANSWER=5,000 sq ft


The International Mechanical Code requires a duct smoke detector in the return for
units over ________ cfm - CORRECT ANSWER=2000 cfm


The International Mechanical Code (IMC) requires a duct smoke detector in the
supply for units over __________ cfm - CORRECT ANSWER=15000


Digital alarm communicator transmitters (DACT) which use call forwarding to the
DACR shall be tested with what frequency? - CORRECT ANSWER=4 hours


NPLFA cables shall be insulated to __________ v - CORRECT ANSWER=600v

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Tutorx Walden University
View profile
Follow You need to be logged in order to follow users or courses
Sold
19
Member since
3 year
Number of followers
15
Documents
453
Last sold
3 months ago
VERIFIED

TopGrade Tutoring: Expert Psychology, Nursing, HR & Math Resources Welcome to my academic support store, your trusted destination for top-tier homework help and tutoring services! Specializing in key subjects like Psychology, Nursing, Human Resource Management, and Mathematics, I’m dedicated to helping students excel with high-quality, meticulously crafted resources. My mission is to deliver scholarly, reliable content that guarantees excellent grades, earning me a reputation as one of Stuvia’s BEST GOLD RATED TUTORS. Whether you need assistance with quizzes, exams, or detailed study materials, I prioritize your success with a commitment to academic excellence and results you can count on.

Read more Read less
4.6

62 reviews

5
40
4
19
3
3
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions