Type I correct answers Type of construction using wood
Type II correct answers Wood construction with protective fire resistant materials and 1-hour
fire-resistive throughout; except the permanent bearing partitions may use fire retardant
treated wood within the framing assembly.
Type III correct answers Masonry and wood construction. Structural elements may be any of
the materials permitted by the Code provided, that the building shall be one-hour fire-
resistive throughout. Exterior walls shall be of incombustible fire-resistive construction.
Type IV correct answers Steel, iron, concrete, or masonry construction and walls, ceiling and
permanent partitions shall be of incombustible fire-resistive construction, except, that
permanent non-bearing partitions of ONE-hour fire-resistive construction may use fire-
retardant treated wood within the framing assembly
Type V correct answers FOUR fire-resistive throughout and the structural elements shall be
of steel, iron, concrete, or masonry construction.
50 correct answers Materials required to be flame-spread proofed shall be treated with a
flame-retardant having a flame-spread of not less than ___________ as determined by the
"Tunnel Test".
Fire Zones correct answers Are areas which only certain types of buildings are permitted to
construct based on their use, type of construction and resistance to fire.
1/3 correct answers A building/structure which is located partly in one (1) fire zone and
partly in another shall be considered to be in the more highly restrictive fire zone, when
______________ of its total floor area is located in such zone.
20% correct answers Damage from fire or earthquake, typhoons or any fortuitous event may
be repaired, using the same kind of materials of which the building or structure was originally
constructed, provided that, the cost of such repair shall not exceed __________of the
replacement cost of the building or structure.
Non-fire Restricted Zones correct answers These are areas where sitting of buildings are
permitted without fire-resistivity. Often located at rural areas. Type 1 and Type 2 of
construction
Fire Restrictive Zones correct answers These are areas where sitting of buildings are
permitted within prescribed fire-resistivity with atleast 2-hour fire resistive. Type 2, Type 3
and type 4 of constructions.
Highly Fire Restrictive Zones correct answers These are areas require no less than 3-hour to
4-hour fire resistive construction materials. Type 4 and Type 5 of construction