National Building Code correct answers P.D. 1096
2.70 m correct answers Maximum height of a combustible stand.
0.85 m correct answers Minimum spacing for seats in a chair type measurement from back to
back.
45.00 m correct answers Maximum line of travel to an exit of an aisle.
1:8 correct answers Maximum slope of an aisle.
0.84 m correct answers In standard seating, the minimum spacing of rows measured from
back to back.
0.45 m correct answers Minimum width of any seat.
1,300 sqmm / 1.30 sqm. correct answers Minimum area of a double acting door view panel.
0.70 m correct answers Minimum clear width of an exit doorway.
1.20 m correct answers Maximum width of an exit door leaf.
1.10 m correct answers Minimum width of an exit corridor.
2 correct answers Minimum number of exit for floors above the first storey having an
occupant load of more than 10
3 correct answers Number of exit for occupant load of 599-999.
0.30 m correct answers Minimum downward projection of a draft curtain
250 sqm correct answers Maximum floor area for an attic made of combustible materials.
1.80 m correct answers Maximum center to center spacing of a draft curtain sprinkler.
750 sqm. correct answers Maximum floor area for an attic made of incombustible materials.
Ga. 18 correct answers Standard gauge for metal hoods in barbeques.
300 mm correct answers Minimum height of a Siamese connection above grade.
300 mm correct answers Standard maximum distance of a standpipe from an opening in a
stairway.
200 mm correct answers Minimum wall thickness of a fireplace.
, 2 correct answers Minimum number of exit for a projection room.
600 mm correct answers Minimum extended portion of a chimney above the roof.
2" / 50 mm correct answers Minimum air space between walls of a masonry chimney above
the roof.
12.5 mm correct answers Minimum thickness of glass used for floors.
400 mm / 0.40 mtr. correct answers Maximum rise of one row of seat to the next.
3 correct answers Minimum number of exit for stands within a building serving an occupant
load of 300.
0.90 m correct answers Minimum height of a guard rail located in front of the grandstand.
0.28 m correct answers Minimum width of a run in a stand stair.
0.75 m correct answers Minimum spacing for seats with backrests measured from back to
back.
0.60 m correct answers Minimum spacing for seats without backrests measured from back to
back.
1.70 m correct answers Minimum width of an exit door in an aisle.
10.70 lux correct answers Minimum intensity of lights for exits.
1.10 m correct answers Minimum width of side aisles.
30 mm correct answers Minimum increase in width of aisles for every linear meter.
800 mm / 0.80 mtr. correct answers Minimum width of SIDE aisle serving only one side.
50% of lot area correct answers Open space requirement for an interior lot.
10% of lot area correct answers Open space requirement for a corner lot or a through lot.
Inner court correct answers Bounded on all sides or around its periphery by building lines.
750 mm / 0.75 mtr. correct answers Minimum stair width for a residence.
1.20 sqm. correct answers Standard minimum area of a toilet.
1.50 m correct answers Minimum dimension of a kitchen.
1.00 sqm. correct answers Minimum area for vent shafts.
3.00 cum. correct answers Air space requirement for a school room per person.