Chapter 9: NFPA 1031 questions and answers graded A+ passed what is the NFPA number for Standard for the Installation of Sprinkler Systems? - ANS NFPA 13 What is the maxmum height stacks can be in a lumberyard? - ANS 6 m Must Be kept in covered safety containers when thehy are not actually in use - ANS Classes 1A through 1C and Class 2 liquids Must not be used in the presence of any possible ignition source such as open flames, electrical arcs, or heating elements - ANS Classes 1A through 1C liquids Cannot be stored in containers that are pressurices with air. In some circumstances, they may be stored in containers that are pressurized with an inert gas - ANS Classes 1A through 1C liquids bonding and ground is not necessary when Class 2 or Classes 3A and 3B liquids are loaded into containers that have previously contained Classes 1A through 1C liquids do to the vapour pressure and resulting in them evaporating - ANS False The most dangerous type of dispensing is when you are pumping from an underground tank. - ANS False The tank pumping or loading hose needs to be replaced every BLANK years? - ANS 5

Content preview

Chapter 9: NFPA 1031 questions and
answers graded A+ passed

what is the NFPA number for National Electrical Code - ANS ✔NFPA 70



Flammable vapors and gases may be present - ANS ✔Class 1 locations



Combustible dust may be found - ANS ✔Class 2 Locations



Ignitable fibers may pose a hazard - ANS ✔Class 3 locations



Loading and unloading stations from Classes 1A through 1C liquids must be located no clsoer
than blank meters from storage tanks, property lies, or adjacent buildings - ANS ✔8 m



Loading and unloading stations for class 2 and class 3A and 3B liquids must be located no claser
than BLANK meters from storage tanks, property lines, or adjacent buildings - ANS ✔5 m



what is required between two mtal storage tanks to protect against static charges - ANS
✔bonding chain



where must control valves be located on tanks? - ANS ✔easily accesible points along the piping
to control the flow



this method uses pallets to store materials, you can stuck multiples of them - ANS ✔pallet
storage

Document information

Uploaded on
September 6, 2025
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StuviaExamHub
3.7
(91)
Sold
491
Followers
356
Items
25355
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions