FLS Director's Quiz (Fire and Non-Fire): Exam
Preparation With Fully Solved Questions

1) Who is responsible to report to the Fire Command Station in the absence of
a FLSD or a Deputy FLSD in an office building after normal business hours?
a) floor warden b) Chief Engineer c) Building Evacuation Supervisor d) Fire
Brigade member Accurate Answer:- C

2) If a building is equipped with a stand pipe only, what color would the
buildings fire department connection be?
a) red b) green c) yellow d) silver Accurate Answer:- A

3) How many floor wardens are required in a 30 story Class B building?
a) one b) 30 c) 60 d) depends on the square footage of each floor
Accurate Answer:- B

4) Which of the following initiating devices must be replaced after it has
activated?
a) rate of rise heat detector b) single action pull station c) carbon monoxide
detector d) fixed temperature heat detector Accurate Answer:- D

5) A technician enters your building to work on your buildings multi zone
standpipe system, as FLSD you should ensure the technician possesses what
certification? (Reference Material)
a) S-97 b) w-96 c) S-11 d) S-14 Accurate Answer:- D

6) Water dripping from an automatic ball drip, after the FDNY has
disconnected from the FDNY connection, is an indication of___________?
a) a defect in the FDNY Connection b) some leakage from this valve is
expected c) indicates a faulty lower check valve d) indicates the system was
overcharged Accurate Answer:- B

7) All of the following are signals received at the Fire Alarm Control Panel
except?
a) alarm signal b) trouble signal c) surge signal d) supervisory signal
Accurate Answer:- C

8) Which of the following will not cause a recall of a buildings elevators?

,a) smoke detector in the elevator lobby b) sprinkler activation c) smoke
detector in elevator machinery room d) manual pull station Accurate
Answer:- D

9) Under the 2014 building code, buildings that are used primarily for
transacting business and rendering professional services would be classified
as____?
a) class J b) class R-1 c) Class A d) Class B Accurate Answer:- D

10) Which of the following is not an action to be taken during a fire or non fire
emergency?
a) shelter in place b) in building relocation c) partial evacuation d) Roof
relocation Accurate Answer:- D

11) If a building has 200 sprinkler heads in it's sprinkler system, how many
spare heads must be kept on the premises? (Reference Material)
a) 6 b) 12 c) 24 d) 10 Accurate Answer:- A

12) All of the following are members of the Fire and Life Safety Staff except?
a) Critical operations staff
b) Deputy Fire and Life Safety Director
c) Deputy Floor Warden
d) owners representative Accurate Answer:- D

13) If a buildings auxiliary radio communication system is out of service, a tag
identifying the system as out if service must be placed at?
a) the entrance to the building
b) at all warden phone locations
c) at the Fire command center
d) at the buildings communications center Accurate Answer:- C

14) Which of the following pumps is designed to operate when there is a slight
drop in pressure due to leakage or a pressure surge?
a) Fire Pump b) booster pump c) special service pump d) Jockey Pump
Accurate Answer:- D

15) The vertical portion of the system piping that delivers the water supply
for hose connections and sprinklers on standalone as well as combined
systems is known as:

, a) cross main b) branch line c) riser d) feed main Accurate Answer:- C

16) The Fire Department recommends that the FLS staff participate in training
designed to familiarize them with their duties. The initial training in both fire
and non-fire training the training duration for FLS brigade members should be
(Both Parts):(Reference Material)
a) two hours b) three hours c) one hour d) thirty minutes Accurate
Answer:- B

17) Which of the following would result in the shutting down of a buildings
HVAC system?
a) manual pull station b) rate of rise heat detector c) duct smoke detector d)
area smoke detector Accurate Answer:- C

18) If the stem on an os&y valve is raised, this indicates a stanpipe system is?
a) on b) out of service c) off d) defective Accurate Answer:- A

19) The Temperature in the fire pump room should be kept at a minimum of:
a) 60 degrees b) 40 degrees c) 32 degrees d) 50 degrees Accurate
Answer:- B

20) The most common standpipe system in operation is:
a) dry standpipe with automatic dry pipe valve b) wet standpipe c) dry
standpipe with no permanent water supply d) yard system Accurate
Answer:- B

1- Upon implementation of the FDNY plan or during the drills, the FLS
Director must identify themselves to building occupants and others by?
a- standing at the fire command station.
b- donning a vest, armband, or other form of identification indicating their
role.
c-responding to the location of the reported emergency.
d-meeting the fire department outside Accurate Answer:- B

2- In the event of a fire, a medical emergency or other non-fire emergency in
the building, the FLS Director must?
a. Always report the fire command stationb. implement such fire safety
and/or non-fire emergency actions as are warranted by the circumstances, in
accordance with the provisions of the FDNY Plan, the Fire Code, and the Fire

Document information

Uploaded on
August 31, 2025
Number of pages
28
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$30.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LeCrae
4.0
(445)
Sold
2126
Followers
1409
Items
22354
Last sold
13 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions