• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 59 pages
Exam (elaborations)

Ct Registry Review (Mic) Latest 2025/26 Verified Questions And Correct Answers Rated 100% A+ Score Solution

Document preview thumbnail
Preview 4 out of 59 pages

CT REGISTRY REVIEW (MIC) LATEST 2025/26 VERIFIED QUESTIONS AND CORRECT ANSWERS RATED 100% A+ SCORE SOLUTION

Content preview

CT REGISTRY REVIEW (MIC) LATEST 2025/26 VERIFIED
QUESTIONS AND CORRECT ANSWERS RATED 100% A+ SCORE
SOLUTION


Important clinical benefits of iterative reconstruction include:
1. Ability to reduce radiation dose without compromising image
quality
2. No longer needing to perform multi-planar reconstructions
3. Reduction in noise seen in the image - ---ANSWERS----1,3

Which statement is FALSE regarding 3D SSD?
A. Helical image data is well suited for 3D SSD because there is
minimal misregistration or gaps
B. The volume data, form which the 3D SSD is generated, is
created by combing transverse, sagittal, and coronal recons.
C. The tissue surface may be selected by using a threshold vaule
equal to the tissue's CT number
D. Patient motion during the scan is detrimental to the quality of
the 3D images - ---ANSWERS----B

What is 3D SSD? - ---ANSWERS----3D (Shaded surface display)
Reconstructed images of the surfaces of anatomical structures

A helical scan performed on a 64 slice MDCT scanner is
reconstructed with: - ---ANSWERS----Cone beam recons

A CT manufacturer has a scanner in which the focal spot of the
x-ray beam can move to two, slightly separated, distinct
locations. What benefit does the dual focal spot provide
compared to an identical scanner possessing a single focal spot?
- ---ANSWERS----The number of projections is doubled

,A __________ scan uses only a single projection - ---ANSWERS--
--Localizer

What does convolutin do to the image quality when it is added to
the back projection reconstruction process?
A. Normalizes the attenuation coefficients to ensure tissues are
displayed with correct CT numbers
B. Increases the number of projection thereby reducing streaking
artifacts.
C. Improves contrast resolution by reducing scatter radiation
D. Enhances important characteristics of attenuation profiles
thus reducing streak and star artifact - ---ANSWERS----D

The ______moves during a helical scan on a third generation
scanner
1. X-ray tube
2. Patient table
3. Detector elements - ---ANSWERS----1,2,3

Which of the following is a reconstruction technique applied to
the raw data after the primary reconstruction has already been
accomplished? - ---ANSWERS----Retrospective recontruction

A smooth, or low pass, reconstruction filter is typically NOT
selected for a(n) _____ exam.
A. Pituitary
B. Kidneys
C. Liver
D. IAC (internal auditory canals) - ---ANSWERS----D

Which is NOT an advantage of a helical study compared to a
conventional serial CT study?

,1. Minimal anatomical misregistration sometimes caused by
inconsistent breath-holding
2. Shorter total exam time
3. Can retrospectively reconstruct a slice at any arbitrary
position
4. Offers the best image quality for a brain exam - ---ANSWERS-
---4

An increase in ___________ does NOT occur in the resulting
images when applying a sharp, or high-pass reconstruction filter
during the image reconstruction of CT raw data.
1. Contrast resolution
2. Edge enhancement
3. Appearance of noise - ---ANSWERS----1

Which of the following utilizes convolution?
1. 3D SSD
2. Fourier tranform
3. Filtered back projection - ---ANSWERS----3

_____________ yields an image that appears 3D but also shows
anatomical details above and below 3D surfaces - ---ANSWERS-
---VR (volume rendering)

Which type of storage media may hold CT image data?
1. Internal hard disk
2. CD
3. Re-writable optical disk - ---ANSWERS----1,2,3

____________ may have to be edited from the data set to get a
diagnostic MIP of a CTA exam - ---ANSWERS----Bones

, In which technique are tissues other than the surface of a
structure excluded by setting a threshold value and eliminating
pixels above or below that threshold? - ---ANSWERS----3D
shaded surface display

Which statement is TRUE:
1. Amplified electrical signal obtained from detectors must be
digitized
2. Digital CT images are numerical representations of cross-
sectional anatomy
3. Digital signals may be formed by sampling analog signals at
discrete time intervals - ---ANSWERS----1,2,3

Muti-planar reconstructions are performed on which of the
following:
A. Image data
B. Raw data
C. Attenuation profiles - ---ANSWERS----A

____________ allows helical data to be converted into planar raw
data - ---ANSWERS----Interpolation

Which of the following may occur during the interscan delay of a
conventional or serial CT scan, performed on a continuous
rotation scanner?
A. Table position is incremented
B. Tube continues to rotate in same direction as during scan
C. Tube assembly makes a 360 degree rotation - ---ANSWERS--
--a,b,c

On a third generation single row detector scanner, if there are
750 detectors and there are 900 projections in a full rotation,
how many samples of attenuation data are collected for the raw

Document information

Uploaded on
August 20, 2025
Number of pages
59
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Kylie6764
5.0
(1)
Sold
11
Followers
0
Items
1420
Last sold
2 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions