Radiation Therapy Board Review || Answered Perfectly 100%.

Document preview thumbnail
Preview 4 out of 66 pages

Prophylactic cranial irradiation for ALL is administered to a total dose of: A. 1200 cGy B. 1800 cGy C. 3000 cGy D. 4500 cGy E. 6000 cGy correct answers B. 1800 cGy The treatment time for a field requiring 350 monitor units while the linear acellerator dose rate is 220 units/minute is: A. .394 minutes B. .629 minutes C. 1.59 minutes D. 2.52 minutes correct answers C. 1.59 minutes Placing marks on the central axis only is: A. Sufficient for daily realignment and targeting B. Sufficient when target margins are small C. Adequate for treating small fields D. Insufficient for daily realignment and targeting correct answers D. Insufficient for daily realignment and targeting *Marks should be placed on the central axis and along coordinate planes to assure the patient and location target is accurately reproduced.

Content preview

Radiation Therapy Board Review || Answered Perfectly 100%.


Prophylactic cranial irradiation for ALL is administered to a total dose of:


A. 1200 cGy
B. 1800 cGy
C. 3000 cGy
D. 4500 cGy
E. 6000 cGy correct answers B. 1800 cGy


The treatment time for a field requiring 350 monitor units while the linear acellerator dose rate is
220 units/minute is:


A. .394 minutes
B. .629 minutes
C. 1.59 minutes
D. 2.52 minutes correct answers C. 1.59 minutes


Placing marks on the central axis only is:


A. Sufficient for daily realignment and targeting
B. Sufficient when target margins are small
C. Adequate for treating small fields
D. Insufficient for daily realignment and targeting correct answers D. Insufficient for daily
realignment and targeting


*Marks should be placed on the central axis and along coordinate planes to assure the patient and
location target is accurately reproduced.

,During total CNS irradiation, the patient is:


A. Supine with an extended chin
B. Supine with chin flexed
C. Prone with chin slightly extended
D. Prone with chin flexed correct answers C. Prone with chin slightly extended


Electron contamination from high energy photon beams may result from photon interactions with
the:


A. Room air
B. Collimators
C. Bolus
D. Lucite trays correct answers B. Collimators


Lucite is often used as the material for positioning devices. One major concern when this
material is in the path of the treatment beam is:


A. Electron contamination
B. Beam attenuation
C. Decreased rigidity
D. Acquired radioactivity correct answers B. Beam attenuation


Advantages of networked digital image management do not include:


A. Dispersed access to images
B. Multiple users can share images

,C. Physical storage space is minimized
D. Computer disk space is not an issue correct answers D. Computer disk space is not an issue


In the treatment of seminoma, an external testicular shield should be used for the remaining
testicle. This is Important since the TD 5/5 for the testis is as low as:


A. 1 Gy
B. 10 Gy
C. 20 Gy
D. 40 Gy correct answers A. 1 Gy


Which of the following cannot produce a 3 dimensional image?


A. MRI
B. CT
C. Ultrasound
D. Electronic portal imaging correct answers D. Electronic portal imaging


A procedure in which an implant is made using a trocar, with radioactive sources introduced into
the trocar and then the trocar is removed is called:


A. Self-attenuation
B. Interstitial preloading
C. Intracavitary microloading
D. Interstitial afterloading correct answers D. Interstitial afterloading


The precise daily reproduction of patient position depends on:

, 1. Patient age
2. Type of treatment machine
3. Anatomical site treated
4. Patients overall health


A. 1 & 2
B. 2 & 3
C. 3 & 4
D. 1 & 4 correct answers C. 3 & 4


The linear scales on the treatment table are used as an aid for:


A. Translation of patient position on the table
B. Verifying filament voltage
C. Verifying gantry readout accuracy
D. Documentation of treatment dose correct answers A. Translation of patient position on the
table


Compared to water, the density of bone is:


A. 1.00
B. 1.65-1.85
C. 0.33-0.35
D. 0.2-0.26 correct answers B. 1.65-1.85


If the width of the vertebral body is 5.3 cm and measures 7.5 cm on the portal verification film,
the magnification factor is:

Document information

Uploaded on
August 20, 2025
Number of pages
66
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$17.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
791
Followers
438
Items
40035
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions