Which of the following is not considered "hanging
hardware"?
a. nozzle
b. swivel
c. whip hose
d. shear valve - Answer-d. shear valve
Per Executive Order. VR-201-E, if the dispensing vacuum
of the Healy VP-1000 pump is below ____ inches of WC,
the dispenser should be removed from service.
A. 50
B. 60
C. 75
D. 100 - Answer-B. 60
,2|Page
In a coaxial hose for a balance system, the product flows
through the ____?
A. the belllows
B. the inner hose
C. the outer hose
D. both hoses - Answer-B. the inner hose
Per the Vapor Recovery Equipment Defects List (VRED),
the ____ of any component required to be used by the
system's EO. Is not considered a defect.
A. absence
B. proper installation
C. disconnection
D. improper installation - Answer-B. proper installation
The three elements in a fire triangle are ____?
A. oxygen, fuel, & LEL
B. fuel, fire, & carbon dioxide
, 3|Page
C. fuel, oxygen, & ignition source
D. ignition source, carbon dioxide, & fuel - Answer-C. fuel,
oxygen, & ignition source
According to PEI RP-300, a combustible gas indicator is
used to?
A. determine carbon dioxide levels
B. monitor benzene, toluene, & ethyl benzene levels
C. determine the (UEL) upper explosion limit of gasoline
D. detect vapor leaks in the vapor recovery system -
Answer-D. detect vapor leaks in the vapor recovery
system
Per CP-201, liquid traps in the dispenser vapor piping are:
A. Not allowed
B. Allowed only with an assist system
C. Allowed if approved by CARB
D. Allowed when hoses with liquid removal systems are
used
ICC Vapor Recovery 1 PART1 &2 Actual Exam
2025/2026 Complete 200 Questions And Correct
Detailed Answers (Verified Answers) |Already Graded
A+|Verified Exams!!|Latest Exam Version!!!
Which of the following is not considered "hanging
hardware"?
a. nozzle
b. swivel
c. whip hose
d. shear valve - Answer-d. shear valve
Per Executive Order. VR-201-E, if the dispensing vacuum
of the Healy VP-1000 pump is below ____ inches of WC,
the dispenser should be removed from service.
A. 50
B. 60
C. 75
D. 100 - Answer-B. 60
,2|Page
In a coaxial hose for a balance system, the product flows
through the ____?
A. the belllows
B. the inner hose
C. the outer hose
D. both hoses - Answer-B. the inner hose
Per the Vapor Recovery Equipment Defects List (VRED),
the ____ of any component required to be used by the
system's EO. Is not considered a defect.
A. absence
B. proper installation
C. disconnection
D. improper installation - Answer-B. proper installation
The three elements in a fire triangle are ____?
A. oxygen, fuel, & LEL
B. fuel, fire, & carbon dioxide
, 3|Page
C. fuel, oxygen, & ignition source
D. ignition source, carbon dioxide, & fuel - Answer-C. fuel,
oxygen, & ignition source
According to PEI RP-300, a combustible gas indicator is
used to?
A. determine carbon dioxide levels
B. monitor benzene, toluene, & ethyl benzene levels
C. determine the (UEL) upper explosion limit of gasoline
D. detect vapor leaks in the vapor recovery system -
Answer-D. detect vapor leaks in the vapor recovery
system
Per CP-201, liquid traps in the dispenser vapor piping are:
A. Not allowed
B. Allowed only with an assist system
C. Allowed if approved by CARB
D. Allowed when hoses with liquid removal systems are
used