• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 10 pages
Exam (elaborations)

DANB RHS practice test TB Questions Correct Solutions Current Update

Document preview thumbnail
Preview 2 out of 10 pages

DANB RHS practice test TB Questions Correct Solutions Current Update The amount of radiation and exposure time needed to produce a diagnostic radiograph is best determined by - Answer- exposure time How is scatter radiation reduced when taking an image? - Answer- use of a rectangular cone What step should be taken immediately if the tubehead drifts? - Answer- stop using the machine The radiation exposure that poses the greatest hazard to the operator is - Answer- leakage radiation The diameter of the cone-shaped beam produced from a circular collimator is - Answer- 2.75 To minimize potential infections from semicritical items, it is important the operator - Answer- clean and disinfect devices after removal of surface barriers Which organization regulates disinfectants and chemical sterilants? - Answer- EPA When changing the 8-inch PID to a 16-inch PID, what is used to determine the intensity of the beam? - Answer- inverse square law Before exposing dental radiographs on a visually impaired patient, - Answer- use touch and explain what the equipment does What is the time between patient exposure to radiation and the appearance of biological damage called? - Answer- latent period What radiographic technique is recommended for a patient with a shallow palate? - Answer- bisecting An underexposed image will appear - Answer- light If there are no teeth to serve as guides, which landmark indicates a maxillary molar area radiograph? - Answer- tuberosity After selecting the appropriate sensor size for the patient when taking a digital radiograph, the next step is to - Answer- place a barrier on the sensor What is the primary function of collimation? - Answer- restrict the size of the beam Which item best protects the dental team member from cross-contamination while exposing radiographs - Answer- gloves Why is it important for the patient to stand up straight when taking a panoramic image? - Answer- to prevent the spine from being superimposed over the anterior teeth The penetrating x-ray beam made during dental radiography is called - Answer- primary radiation Foreshortening of the maxillary radiographic image results from - Answer- increased vertical angulation The Frankfort Plane is an imaginary plane passing through the - Answer- external auditory meatus to the floor of the orbit Compared to a dentulous patient, radiographic exposure time on an edentulous adult patient should - Answer- decrease A panoramic radiograph with a dark shadow over the apices of the maxillary teeth may be caused by the patient - Answer- not placing the tongue against the palate ALARA is primarily concerned with the radiation that is - Answer- artificial When taking a panoramic radiograph, the patient's head should be oriented - Answer- with the midsagittal place perpendicular to the floor Radiation injury can be measured by - Answer- dose rate After a radiographic procedure, the PID should be - Answer- disinfected What are common uses for a CBCT 3D image? - Answer- determining bone structure and tooth orientation The shorter the wavelength of electromagnetic radiation, the greater the - Answer- energy The maximum permissible dose (MPD) of ionizing radiation for occupational exposure is - Answer- 5 If a patient does not remove earrings before a panoramic radiograph is exposed, the image may have - Answer- ghost images

Content preview

DANB RHS practice test TB Questions
Correct Solutions Current Update
The amount of radiation and exposure time needed to produce a diagnostic radiograph
is best determined by - Answer- exposure time

How is scatter radiation reduced when taking an image? - Answer- use of a rectangular
cone

What step should be taken immediately if the tubehead drifts? - Answer- stop using the
machine

The radiation exposure that poses the greatest hazard to the operator is - Answer-
leakage radiation

The diameter of the cone-shaped beam produced from a circular collimator is - Answer-
2.75

To minimize potential infections from semicritical items, it is important the operator -
Answer- clean and disinfect devices after removal of surface barriers

Which organization regulates disinfectants and chemical sterilants? - Answer- EPA

When changing the 8-inch PID to a 16-inch PID, what is used to determine the intensity
of the beam? - Answer- inverse square law

Before exposing dental radiographs on a visually impaired patient, - Answer- use touch
and explain what the equipment does

What is the time between patient exposure to radiation and the appearance of biological
damage called? - Answer- latent period

What radiographic technique is recommended for a patient with a shallow palate? -
Answer- bisecting

An underexposed image will appear - Answer- light

If there are no teeth to serve as guides, which landmark indicates a maxillary molar area
radiograph? - Answer- tuberosity

After selecting the appropriate sensor size for the patient when taking a digital
radiograph, the next step is to - Answer- place a barrier on the sensor

What is the primary function of collimation? - Answer- restrict the size of the beam

, Which item best protects the dental team member from cross-contamination while
exposing radiographs - Answer- gloves

Why is it important for the patient to stand up straight when taking a panoramic image? -
Answer- to prevent the spine from being superimposed over the anterior teeth

The penetrating x-ray beam made during dental radiography is called - Answer- primary
radiation

Foreshortening of the maxillary radiographic image results from - Answer- increased
vertical angulation

The Frankfort Plane is an imaginary plane passing through the - Answer- external
auditory meatus to the floor of the orbit

Compared to a dentulous patient, radiographic exposure time on an edentulous adult
patient should - Answer- decrease

A panoramic radiograph with a dark shadow over the apices of the maxillary teeth may
be caused by the patient - Answer- not placing the tongue against the palate

ALARA is primarily concerned with the radiation that is - Answer- artificial

When taking a panoramic radiograph, the patient's head should be oriented - Answer-
with the midsagittal place perpendicular to the floor

Radiation injury can be measured by - Answer- dose rate

After a radiographic procedure, the PID should be - Answer- disinfected

What are common uses for a CBCT 3D image? - Answer- determining bone structure
and tooth orientation

The shorter the wavelength of electromagnetic radiation, the greater the - Answer-
energy

The maximum permissible dose (MPD) of ionizing radiation for occupational exposure is
- Answer- 5

If a patient does not remove earrings before a panoramic radiograph is exposed, the
image may have - Answer- ghost images

When taking an occlusal radiograph, the PSP packet should extend from the patient's
mouth by approximately - Answer- 1/8-1/4

Document information

Uploaded on
August 14, 2025
Number of pages
10
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ScholarExams
3.8
(75)
Sold
400
Followers
186
Items
11775
Last sold
14 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions