1. One of the significant causes of leaks in underground liquid storage systems is ____________ ________________ Improper Installation 2. Written Plans are required to obtain permits, solicit bids, and provide precise guidance for installers. 3. The plans should Describe the property, identify the size and location of the tanks, indicate the liquids to be stored and provide the location of the dispensers and piping. 4. Storage systems discussed in this recommended practice are usually regulated by Federal, state or local agencies. 5. All owners should ensure that the equipment to be installed meets applicable regulatory requirements before being installed 6. Consult the local authorities who have jurisdiction in the area before storage-system plans are finalized or construction is initiated. 7. All owners should ensure that the equipment to be installed meets all applicable regulatory requirements before Being installed. 8. To avoid damage tanks must not be dropped, dragged, or handled with sharp objects. 9. Tanks must not be dropped, dragged, or handled with sharp objects to avoid Damage to the tank U1 UST INSTALLATION/RETROFITTING EXAM 2025 QUESTIONS AND ANSWERS @COPYRIGHT FYNDLAY 2025/2026 Page2 10. The only time tanks really should be moved is when for inspections and testing. 11. If a tanks is damaged at all throughout the moving process it must be Repaired in accordance with the manufacture's instructions. 12. The proper way to move a tank is by lifting it, using the Lift lugs that are installed by the manufacturer. 13. Tanks should be carefully lifted and lowered using Cables or chains of adequate length. 14. When two lifting lugs are being used, the angle between the lifting cable and vertical should be no more than 30 degrees. 15. Stockpile piping materials and equipment in a _____________ _________ on the job site Secure area 16. Confirm adherence to specifications by reporting to the owner about any detected damage that could result in leakage or premature corrosion. 17. Pressure test single-walled tanks with _____ to _______ psig air pressure, soaping all surfaces, seams and fittings while inspecting for bubbles. 3 to 5 18. Air testing with over ___ psig (3 Psig for 12-Ft. Diameter FRP tanks) is hazardous and may damage the tank 5 psig 19. Do not air test a tank that has previously contained flammable or combustible liquids 20. Place ______ barricades at the ends of tanks being tested. Warning 21. Avoid tank ends, man-ways, and fittings while the tank is under Pressure @COPYRIGHT FYNDLAY 2025/2026 Page3 22. Release pressure in the tank before disconnecting any gauges or test fittings. 23. Be aware some manufactures do not tighten fittings to allow for _____________ _____________ during shipping and storage. Temperature changes 24. True or False: Air tests are inconclusive without soaping and careful inspection for bubbles? True 25. Tanks gauges must have a scale that will permit detection of small changes in __________ that might go undetected on gauges with a ___________ _________. Pressure, broader range. 26. Since the best accuracy of gauges is at mid-range, and test pressures must not exeed 5 psig, use a gauge with a maximum limit of ____ or ______ 10 or 15 psig 27. Check the gauges __________ and _________ before use operation and accuracy 28. Underground storage systems may include vapor-recovery Piping and equipment 29. What ca

Content preview

U1 UST INSTALLATION/RETROFITTING
EXAM 2025 QUESTIONS AND ANSWERS


1. One of the significant causes of leaks in underground liquid storage systems is
____________ ________________ Improper Installation


2. Written Plans are required to obtain permits, solicit bids, and provide precise guidance for
installers.


3. The plans should Describe the property, identify the size and location of the tanks, indicate
the liquids to be stored and provide the location of the dispensers and piping.


4. Storage systems discussed in this recommended practice are usually regulated by Federal,
state or local agencies.


5. All owners should ensure that the equipment to be installed meets applicable regulatory
requirements before being installed


6. Consult the local authorities who have jurisdiction in the area before storage-system plans
are finalized or construction is initiated.


7. All owners should ensure that the equipment to be installed meets all applicable regulatory
requirements before Being installed.


8. To avoid damage tanks must not be dropped, dragged, or handled with sharp objects.


9. Tanks must not be dropped, dragged, or handled with sharp objects to avoid Damage to the
1




tank
Page




@COPYRIGHT FYNDLAY 2025/2026

, 10. The only time tanks really should be moved is when for inspections and testing.


11. If a tanks is damaged at all throughout the moving process it must be Repaired in
accordance with the manufacture's instructions.


12. The proper way to move a tank is by lifting it, using the Lift lugs that are installed by the
manufacturer.


13. Tanks should be carefully lifted and lowered using Cables or chains of adequate length.


14. When two lifting lugs are being used, the angle between the lifting cable and vertical should
be no more than 30 degrees.


15. Stockpile piping materials and equipment in a _____________ _________ on the job site
Secure area


16. Confirm adherence to specifications by reporting to the owner about any detected damage
that could result in leakage or premature corrosion.


17. Pressure test single-walled tanks with _____ to _______ psig air pressure, soaping all
surfaces, seams and fittings while inspecting for bubbles. 3 to 5


18. Air testing with over ___ psig (3 Psig for 12-Ft. Diameter FRP tanks) is hazardous and may
damage the tank 5 psig


19. Do not air test a tank that has previously contained flammable or combustible liquids


20. Place ______ barricades at the ends of tanks being tested. Warning
2
Page




21. Avoid tank ends, man-ways, and fittings while the tank is under Pressure

@COPYRIGHT FYNDLAY 2025/2026

, 22. Release pressure in the tank before disconnecting any gauges or test fittings.


23. Be aware some manufactures do not tighten fittings to allow for _____________
_____________ during shipping and storage. Temperature changes


24. True or False: Air tests are inconclusive without soaping and careful inspection for bubbles?
True


25. Tanks gauges must have a scale that will permit detection of small changes in __________
that might go undetected on gauges with a ___________ _________. Pressure, broader range.


26. Since the best accuracy of gauges is at mid-range, and test pressures must not exeed 5 psig,
use a gauge with a maximum limit of ____ or ______ 10 or 15 psig


27. Check the gauges __________ and _________ before use operation and accuracy


28. Underground storage systems may include vapor-recovery Piping and equipment


29. What can cause premature storage-system failures _________ Debris and other foreign
materials


30. Tank installers should have gone through training programs to improve their skills and
insure the install is __________ Successful


31. __________ kinds of plans are required to obtain permits, solicit bids, and provide precise
guidance for installers written


32. ___________________ should insure that the equipment to be installed meets all
applicable regulatory requirements before beginning an installation Owners
3
Page




@COPYRIGHT FYNDLAY 2025/2026

Document information

Uploaded on
August 13, 2025
Number of pages
22
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$12.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Fyndlay
3.6
(79)
Sold
441
Followers
82
Items
22077
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions