The EC F Gas Regulations 517/2014 requires refrigeration systems containing > 50 and
< 500 of an HFC refrigerant without an automatic leak detector to be leak tested? -
CORRECT ANSWER 6 monthly

Which of the following TEV superheat settings is likely to cause refrigeration system
hermetic compressor to run continuously and overheat? - CORRECT ANSWER 20K

Under the F Gas Regulations when should a newly installed system be checked for
refrigeration leakage? - CORRECT ANSWER Immediately after being put into service

The residual flux that is left on the outside of a brazed joint must be removed because?
- CORRECT ANSWER The flux absorbs water from the air and corrodes the
pipework

What pipe diameter is least likely to fail when carrying out the strength test using OFN?
- CORRECT ANSWER 1 inch

Which one of the following effects would result in an increase in system efficiency? -
CORRECT ANSWER A reduction in vapour specific volume

The ODP of the refrigerant R22 is? - CORRECT ANSWER 0.05

What would cause a reduction in the efficiency of a cooling plant? - CORRECT
ANSWER High pressure ratio

Which one of the following would improve the energy efficiency of an air conditioning or
refrigeration system the most? - CORRECT ANSWER Lowering the condensing
temperature and raising the evaporating temperature

Why might a unit short cycle on low pressure control? - CORRECT ANSWER
Refrigerant loss

What refrigerant is covered by the requirements of EC Regulations 517/2014? -
CORRECT ANSWER R404A

What identifies that a system may have lost refrigerant? - CORRECT ANSWER
Bubbles in the sight glass

, The term indirect leak checking refers to? - CORRECT ANSWER The calculation of
the correct operating conditions by taking pressure and temperature readings

To find a suspected refrigerant leak on a freezer room evaporator it's best to? -
CORRECT ANSWER Leak test the evaporator with the unit in shut down

If the fins on the evaporator become blocked what is the result on the suction vapour? -
CORRECT ANSWER Pressure and temperature fall

To calculate the system compression ratio? - CORRECT ANSWER Divide discharge
pressure by suction pressure (gauge)

What would make ice form around a TEV and possibly cause the pipe work damage? -
CORRECT ANSWER Short of refrigerant

A refrigeration system contains a refrigerant at a dew point condition of -25 degrees,
you would like? - CORRECT ANSWER 5k of superheat

The unit measurement of specific volume as found on a pressure empathy chart is? -
CORRECT ANSWER m3/kg

Which would result in an increase in system efficiency? - CORRECT ANSWER
Reduction in specific volume at compressor inlet

Which refrigerant conditions will provide a clear liquid line sight glass? - CORRECT
ANSWER Subcooled liquid

What is reasonable condensing temperature for evaporative condensers? - CORRECT
ANSWER Air on the condenser wet bulb + 10k

What leak detection method will be ineffective on refrigeration systems charged with
zeotropic refrigerant? - CORRECT ANSWER Halide lamp

Which refrigerant has the lowest GWP? - CORRECT ANSWER R32

Using unfiltered/untreated water in a water-cooled condenser will? - CORRECT
ANSWER Raise discharge pressure and raise discharge temperature

What may cause the system to trip out on a High Pressure (HP) switch? - CORRECT
ANSWER Dirty condenser

The EC F Gas Regulations 517/2014 requires refrigeration systems containing >5 and
<50 of an HFC refrigerant without an automatic leak detector to be leak tested? -
CORRECT ANSWER 12 monthly

Document information

Uploaded on
August 7, 2025
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CornelWest
3.7
(267)
Sold
1661
Followers
1131
Items
13726
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions