Answers | 100% Solved
FL FOR 1 3/4 inch hose - 🧠 ANSWER ✔✔32psi per 100 ft
FL FOR 1 1/2 inch hose - 🧠 ANSWER ✔✔30 psi per 100 ft
Difference between sb hL and ms - 🧠 ANSWER ✔✔350 gpm
29.7 x d2 x np - 🧠 ANSWER ✔✔Formula for sb nozzles
10 psi - 🧠 ANSWER ✔✔Fl for eye/Siamese
Fl for msd - 🧠 ANSWER ✔✔20
25psi - 🧠 ANSWER ✔✔Stand pipe
0.5 psi per ft - 🧠 ANSWER ✔✔Fl for elevation
200 gpm in 1 3/4 in - 🧠 ANSWER ✔✔50
, 250gpm in 2 1/2 fl - 🧠 ANSWER ✔✔15
1hr - 🧠 ANSWER ✔✔Service test
Certification test - 🧠 ANSWER ✔✔3 hr
2 1/2 in redline - 🧠 ANSWER ✔✔36 psi or 400 gpm
3in redline - 🧠 ANSWER ✔✔31 psi or 600 gpm
Static minus residual = - 🧠 ANSWER ✔✔Drop
How does foam work - 🧠 ANSWER ✔✔Suppressing vapors
NFPA 1901 - 🧠 ANSWER ✔✔Automotive Fire Apparatus
Nfpa 1002 - 🧠 ANSWER ✔✔Driver operator
Nfpa 1911 - 🧠 ANSWER ✔✔Service testing
Pump parts - 🧠 ANSWER ✔✔Impeller,eye,vanes,volute housing, discharge shroud
Exhaust, vacuum, rotary gear, rotary vane - 🧠 ANSWER ✔✔Primers
Sb ms 1 1/2 gpm? - 🧠 ANSWER ✔✔600
Sb ms 1 7/8 gpm? - 🧠 ANSWER ✔✔900