Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 1 out of 3 pages
Exam (elaborations)

Radiation Therapy Exam Real Questions And Answers | Verified

Document preview thumbnail
Preview 1 out of 3 pages

Radiation Therapy Exam Real Questions And Answers | Verified The ALARA principle applies for - Answer- Occupational workers, patients, visitors end members of general public The filter in a flim badge is made of - Answer- Copper and Aluminun Occupational workers may not receive more than__________to their hands - Answer- 25 mrem/quarter The formula for dose equivalent in Sieverts (SV) is: - Answer- Dose Eq. (SV) = dose [Gy] x Q One rem is equal to - Answer- .01 Sv Linear Energy Transfer is defined as - Answer- Energy absorbed per path length of ionizing particle When space is not a problem, the choice of shielding material for megavoltage rooms is: - Answer- Concrete Is _____considered an example of a non-stochastic radiation effect - Answer- Lens opacification The two types of microwave power sources used in linear accelerators today are - Answer- Klystrons and Magnetrons As compared to kilovoltage x-ray, which of the following statements are considered advantages of megavoltage therapy? - Answer- Skin sparing & Less lateral scatter The type of target found in a linear accelerator is called a - Answer- Transmission target When using a thoraeus filter, the _____ layer must always be nearest the patient - Answer- Aluminum When the light over the treatment room door is on it signifies - Answer- The radiation beam is on One of the daily checks on linear accelerators is to check the vacuum of the waveguide. Normally, the reading is - Answer- 0 (zero) To clear a MODE FAULT, you must press the - Answer- Beam off/reset button The hazard associated with the operation of a linear accelerator that could cause retinal eye damage is - Answer- Laser beams Which of the following factors must be known in order to calibrate a megavoltage - Answer- Treatment room temperature Barometric pressure Standard calibration factor for ion chamber The depth in a phantom that is recommended for the calibration of a high energy [4-15MV] linear accelerator is - Answer- Dmax The name of the radiation instrument that would best be used to locate an iridium seed which fell on the floor is - Answer- Geiger-Muller Counter Which of the following situations is the most likely reason that the light field and the radiation field do not coincide - Answer- Range finder light needs adjustment Following repairs to the linear accelerator's field/distance light assembly, which of the following checks must be performed prior to resuming treatments? - Answer- SSD/SAD readouts & Light field/radiation field coincidence While treating a patient using a rotational technique, the gantry rotates past the stop point. This is most likely a malfunction of the - Answer- Limit switch Which of the following parameters must be provided in order to determine the monitor units per degree for an arc rotation treatment - Answer- Number of cGys per treatment & Degrees in rotation In order to check the centering of isocentric units, a film is placed to approximate the central ray with exposures being made at the nine gantry positions spaced ____ apart - Answer- 40 degrees Calculate the BOT to treat AP/PA fields at midplane. Patient separation is 10 cm, PDD is 72%. OPF is 1.03 r/mu and dose rate in air is 1.00 r/mu. Blocking tray absorbs 3% of beam daily dose is 250 cGy. - Answer- 173.6 =174 An incorrect rotation of the machine or patient could cause - Answer- 1. Missing part of the tumor 2. Irradiating healthy soft tissue unnecessarily 3. Irradiating a vital organ unnecessarily

Content preview

Radiation Therapy Exam Real
Questions And Answers | Verified
The ALARA principle applies for - Answer- Occupational workers, patients, visitors end
members of general public

The filter in a flim badge is made of - Answer- Copper and Aluminun

Occupational workers may not receive more than__________to their hands - Answer-
25 mrem/quarter

The formula for dose equivalent in Sieverts (SV) is: - Answer- Dose Eq. (SV) = dose
[Gy] x Q

One rem is equal to - Answer- .01 Sv

Linear Energy Transfer is defined as - Answer- Energy absorbed per path length of
ionizing particle

When space is not a problem, the choice of shielding material for megavoltage rooms
is: - Answer- Concrete

Is _____considered an example of a non-stochastic radiation effect - Answer- Lens
opacification

The two types of microwave power sources used in linear accelerators today are -
Answer- Klystrons and Magnetrons

As compared to kilovoltage x-ray, which of the following statements are considered
advantages of megavoltage therapy? - Answer- Skin sparing & Less lateral scatter

The type of target found in a linear accelerator is called a - Answer- Transmission target

When using a thoraeus filter, the _____ layer must always be nearest the patient -
Answer- Aluminum

When the light over the treatment room door is on it signifies - Answer- The radiation
beam is on

One of the daily checks on linear accelerators is to check the vacuum of the waveguide.
Normally, the reading is - Answer- 0 (zero)

To clear a MODE FAULT, you must press the - Answer- Beam off/reset button

Document information

Uploaded on
August 1, 2025
Number of pages
3
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers
$10.94

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Stuviaascorers
3.8
(69)
Sold
379
Followers
185
Items
11040
Last sold
1 day ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions