RADIATION THERAPY MOCK EXAM 1



Which of the following types of treatments is normally accomplished using a source to
skin distance of 50 cm or more:

1. Superficial
2. Supervoltage
3. Orthovoltage
4. Megavoltage

A. 1 & 3
B. 2 & 4
C. 1, 2, and 3
D. All choices - Correct Answers -B. 2 & 4

The most common solid tumor in children is:

A. Retinoblastoma
B. ALL
C. Ewings Sarcoma
D. Medulloblastoma - Correct Answers -D. Medulloblastoma

Which of the following methods can be used for calibration?

A. Ionization
B. Photographic
C. Thermoluminescent dosimetry
D. All choices - Correct Answers -D. All choices

All are true regarding the location of the spleen EXCEPT:

A. Between T11-L3
B. Close to the 9th-11th ribs
C. End 5 cm to the midline
D. Lies posteriorly in the left hypochondrium - Correct Answers -A. Between T11-L3

Primary CNS Tumors use the following staging system:

A. Ann Arbor Staging
B. FIGO

,C. French American British staging
D. Grade staging - Correct Answers -D. Grade staging

Malfunction of radiation monitoring devices may occur due to:

1. Power failure
2. Humidity
3. Damage to probe
4. Meter failure

A. 1 only
B. 2 only
C. 1 & 3
D. 1, 3, and 4 only - Correct Answers -D. 1, 3, and 4 only

When calibrating ionization chambers, which of the following correction factors is NOT
needed?

A. Barometric pressure
B. Elevation
C. Temperature
D. Beam energy - Correct Answers -D. Beam energy

The most common metastatic site from head and neck cancer is:

A. Brain
B. Bone
C. Lung
D. Liver - Correct Answers -C. Lung

Which radiation monitoring device is composed of ferrous sulfate, sodium chloride, and
sulfuric acid?

A. TLD
B. OSL
C. Fricke dosimeter
D. Ionization chamber
E. Cutie Pie - Correct Answers -C. Fricke dosimeter

The instrument used for recording higher energy gamma and x-radiation and beta
particles specifically for contamination and measurement of radioactivity is the:

A. Geiger-Mueller counter
B. Cutie Pie
C. Ionization chamber
D. None of these - Correct Answers -B. Cutie Pie

,The most common histopathology for head neck cancers is:

A. Adenocarcinoma
B. Squamous cell carcinoma
C. Transitional cell carcinoma
D. Clear cell carcinoma - Correct Answers -B. Squamous cell carcinoma

A 42 year old male who has been working in the field for 10 years would have a lifetime
exposure of:

A. 4.2 rem
B. 42 rem
C. .05 rem
D. 5 rem - Correct Answers -B. 42 rem

* 1 rem per year in age is allowed

Which of the following are required on the personnel monitoring report:

1. Birth date
2. Cumulative lifetime exposure
3. Cumulative annual skin dose

A. 1 & 2
B. 1 & 3
C. 2 & 3
D. All choices - Correct Answers -A. 1 & 2

The most common cancer in children is:

A. Retinoblastoma
B. ALL
C. Ewings Sarcoma
D. Medulloblastoma - Correct Answers -B. ALL

The annual dose limit for occupational exposure to the hands is ____ annually. - Correct
Answers -50 rem or 500 mSv

If distance is doubled, the intensity of the radiation will be:

A. Reduced by half
B. Increased by a factor of 2
C. Reduced by a factor of 4
D. Increased by a factor of 4 - Correct Answers -C. Reduced by a factor of 4

, An area where the radiation level could reach 60 mrem/hr would be classified as:

A. Radiation area
B. High radiation area
C. Very high radiation area
D. Dangerous radiation area - Correct Answers -A. Radiation area

Notice should be posted where radiation exposure has potential. An area above 100
mrem/hr must have a sign saying "Caution: High radiation area". Exposure below that
can just read "radiation area."

When a patient is treated with radioactive Iodine 131, the room should have a label that
reads:

A. "High Radiation-Grave Danger"
B. "Caution: Radioactive Materials"
C. "Caution: High Dose Radiation"
D. "Do Not Enter: Radiation at Excessive Levels" - Correct Answers -B. "Caution:
Radioactive Materials"

Where sources of radiation are stored and used, there should always be warning signs
posted saying, "Caution: Radioactive Materials."

When calibrating ion chambers, which of the following correction favors are needed?

A. Barometric pressure
B. Volume of the chamber
C. Temperature
D. Beam energy
E. A & B
F. B & D
G. A, B, and C
D. A, B, C, and D - Correct Answers -G. A, B, and C

For a controlled area, the shielding must be sufficient to reduce exposure to no more
than:

A. 1 mrem/hr
B. 10 mrem/hr
C. 1 mrem/week
D. 100 mrem/week - Correct Answers -D. 100 mrem/week

For sufficient shielding, exposure has to be be reduced to 100 mrem/week (.1
rem/week) for a controlled area.

A stochastic effect is best defined as one in which:

Written for

Institution
Radiation therapy
Course
Radiation therapy

Document information

Uploaded on
July 30, 2025
Number of pages
35
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
RADIATION THERAPY EXAM BUNDLE (WITH VERIFIED SOLUTIONS ) GRADED A
-
50 2025
$ 255.79 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
millyphilip West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
2943
Member since
4 year
Number of followers
1961
Documents
45415
Last sold
1 day ago
white orchid store

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3.6

554 reviews

5
240
4
88
3
104
2
32
1
90

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions