NCIDQ Exam Building Code
Requirements Exam Questions With
Correct Answers
What |is |the |portion |of |the |exit |access |that |must |be |traversed |BEFORE |2 |separate |distinct |
paths |of |travel |to |2 |exits |are |available? |- |CORRECT |ANSWER✔✔-Common |Path |of |Egress |Travel
What |is |the |distance |measured |from |the |most |remote |point |within |a |story |to |the |entrance |to |
an |exit |along |the |natural |and |unobstructed |path |of |egress |travel? |- |CORRECT |ANSWER✔✔-
Travel |Distance
What |are |the |5 |construction |types |that |all |buildings |must |be |classified |within? |- |CORRECT |
ANSWER✔✔-Building |Types:
Type |1 |& |2 |(most |fire |resistant)
Type |3
Type |4
Type |5 |(least |fire |resistant)
What |type |of |construction |uses |noncombustible |building |materials? |- |CORRECT |ANSWER✔✔-
Building |Type |1 |& |2
What |type |of |construction |has |exterior |walls |are |of |noncombustible |materials |and |the |interior |
building |elements |of |any |material |permitted |by |this |code? |- |CORRECT |ANSWER✔✔-Building |
Type |3
What |type |of |construction |has |exterior |walls |are |of |noncombustible |materials |and |the |interior |
building |elements |are |of |solid |laminate |wood |without |concealed |spaces. |- |CORRECT |
ANSWER✔✔-Building |Type |4 |
Heavy |Timber |(HT)
,What |type |of |construction |uses |any |materials |permitted |by |this |code |for |structural |elements, |
exterior |walls, |and |interior |walls? |- |CORRECT |ANSWER✔✔-Building |Type |5
Demising |partitions |between |tenant |spaces |must |be |____ |-hour |fire |rated. |- |CORRECT |
ANSWER✔✔-1-hour
Partitions |along |a |public |corridor |must |be |___ |-hour |fire |rated. |- |CORRECT |ANSWER✔✔-1-
hour
Partitions |that |demise |as |Assembly |Occupancy |of |_____ |size |or |greater |must |have |a |_____ |fire
|rating. |- |CORRECT |ANSWER✔✔-750 |square |feet; |1-hour
A |____________ |fire |separation |is |required |between |an |Assembly |Occupancy |and |a |
Mercantile |Occupancy. |- |CORRECT |ANSWER✔✔-2 |hour
In |a |wall |assembly |with |a |fire |resistance |rating |of |30 |minutes, |what |kind |door |must |be |used? |-
|CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |20 |minutes
In |a |wall |assembly |with |a |fire |resistance |rating |of |45 |minutes, |what |kind |door |must |be |used? |-
|CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |45 |minutes
In |a |wall |assembly |with |a |fire |resistance |rating |of |1 |hour, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |45 |minutes
In |a |wall |assembly |with |a |fire |resistance |rating |of |1.5 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |1 |hour
, In |a |wall |assembly |with |a |fire |resistance |rating |of |2 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |1.5 |hours
In |a |wall |assembly |with |a |fire |resistance |rating |of |3 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |2 |hours
In |a |wall |assembly |with |a |fire |resistance |rating |of |4 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |3 |hours
When |can |a |door |with |a |fire-protection |rating |of |20+ |mins |be |used |in |a |wall |assembly |of |FR |
less |than |1-hour? |- |CORRECT |ANSWER✔✔-When |the |door |is |located |between |a |public |
corridor |and |a |suite
All |door |assemblies |requiring |fire-protection |rating |shall |have |___________ |devices. |- |
CORRECT |ANSWER✔✔-Self-Closing
Storage |rooms |exceeding |_______ |must |be |1-hour |rated. |- |CORRECT |ANSWER✔✔-100 |square |
feet
Glazing |in |fire |rated |partitions, |doors, |or |sidelights |may |NOT |exceed |__________. |- |CORRECT |
ANSWER✔✔-240 |square |inches
Where |are |audio/visual |fire |devices |required |to |be |located? |- |CORRECT |ANSWER✔✔-In |each |
restroom, |hallway, |lobby, |and |general |assembly |area
An |audio/visual |fire |signal |device |must |be |visible |from |any |location |in |the |space |and |must |be |
mounted |between |________ |AFF. |- |CORRECT |ANSWER✔✔-6'-8" |to |7'-6"
1 |fire |extinguisher |per |_______ |square |feet, |minimum. |- |CORRECT |ANSWER✔✔-3,000 |square |
feet
Requirements Exam Questions With
Correct Answers
What |is |the |portion |of |the |exit |access |that |must |be |traversed |BEFORE |2 |separate |distinct |
paths |of |travel |to |2 |exits |are |available? |- |CORRECT |ANSWER✔✔-Common |Path |of |Egress |Travel
What |is |the |distance |measured |from |the |most |remote |point |within |a |story |to |the |entrance |to |
an |exit |along |the |natural |and |unobstructed |path |of |egress |travel? |- |CORRECT |ANSWER✔✔-
Travel |Distance
What |are |the |5 |construction |types |that |all |buildings |must |be |classified |within? |- |CORRECT |
ANSWER✔✔-Building |Types:
Type |1 |& |2 |(most |fire |resistant)
Type |3
Type |4
Type |5 |(least |fire |resistant)
What |type |of |construction |uses |noncombustible |building |materials? |- |CORRECT |ANSWER✔✔-
Building |Type |1 |& |2
What |type |of |construction |has |exterior |walls |are |of |noncombustible |materials |and |the |interior |
building |elements |of |any |material |permitted |by |this |code? |- |CORRECT |ANSWER✔✔-Building |
Type |3
What |type |of |construction |has |exterior |walls |are |of |noncombustible |materials |and |the |interior |
building |elements |are |of |solid |laminate |wood |without |concealed |spaces. |- |CORRECT |
ANSWER✔✔-Building |Type |4 |
Heavy |Timber |(HT)
,What |type |of |construction |uses |any |materials |permitted |by |this |code |for |structural |elements, |
exterior |walls, |and |interior |walls? |- |CORRECT |ANSWER✔✔-Building |Type |5
Demising |partitions |between |tenant |spaces |must |be |____ |-hour |fire |rated. |- |CORRECT |
ANSWER✔✔-1-hour
Partitions |along |a |public |corridor |must |be |___ |-hour |fire |rated. |- |CORRECT |ANSWER✔✔-1-
hour
Partitions |that |demise |as |Assembly |Occupancy |of |_____ |size |or |greater |must |have |a |_____ |fire
|rating. |- |CORRECT |ANSWER✔✔-750 |square |feet; |1-hour
A |____________ |fire |separation |is |required |between |an |Assembly |Occupancy |and |a |
Mercantile |Occupancy. |- |CORRECT |ANSWER✔✔-2 |hour
In |a |wall |assembly |with |a |fire |resistance |rating |of |30 |minutes, |what |kind |door |must |be |used? |-
|CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |20 |minutes
In |a |wall |assembly |with |a |fire |resistance |rating |of |45 |minutes, |what |kind |door |must |be |used? |-
|CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |45 |minutes
In |a |wall |assembly |with |a |fire |resistance |rating |of |1 |hour, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |45 |minutes
In |a |wall |assembly |with |a |fire |resistance |rating |of |1.5 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |1 |hour
, In |a |wall |assembly |with |a |fire |resistance |rating |of |2 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |1.5 |hours
In |a |wall |assembly |with |a |fire |resistance |rating |of |3 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |2 |hours
In |a |wall |assembly |with |a |fire |resistance |rating |of |4 |hours, |what |kind |door |must |be |used? |- |
CORRECT |ANSWER✔✔-Door |assembly |with |a |fire |protection |rating |of |3 |hours
When |can |a |door |with |a |fire-protection |rating |of |20+ |mins |be |used |in |a |wall |assembly |of |FR |
less |than |1-hour? |- |CORRECT |ANSWER✔✔-When |the |door |is |located |between |a |public |
corridor |and |a |suite
All |door |assemblies |requiring |fire-protection |rating |shall |have |___________ |devices. |- |
CORRECT |ANSWER✔✔-Self-Closing
Storage |rooms |exceeding |_______ |must |be |1-hour |rated. |- |CORRECT |ANSWER✔✔-100 |square |
feet
Glazing |in |fire |rated |partitions, |doors, |or |sidelights |may |NOT |exceed |__________. |- |CORRECT |
ANSWER✔✔-240 |square |inches
Where |are |audio/visual |fire |devices |required |to |be |located? |- |CORRECT |ANSWER✔✔-In |each |
restroom, |hallway, |lobby, |and |general |assembly |area
An |audio/visual |fire |signal |device |must |be |visible |from |any |location |in |the |space |and |must |be |
mounted |between |________ |AFF. |- |CORRECT |ANSWER✔✔-6'-8" |to |7'-6"
1 |fire |extinguisher |per |_______ |square |feet, |minimum. |- |CORRECT |ANSWER✔✔-3,000 |square |
feet