CUSP - T&D EXAM STUDY GUIDE 2025/2026 COMPLETE QUESTIONS BANK AND CORRECT DETAILED ANSWERS WITH RATIONALES || 100% GUARANTEED PASS BRAND NEW VERSION 1. As per CAN/ULC S801, on an electrical distribution overhead utility line circuit, verification of voltage absence can be achieved by: - ANSWER Using an approved voltage detector. 2. Isolation and tagging (no locks) is acceptable on an overhead distribution circuit under some of the following conditions, EXCEPT for: - ANSWER The isolation can be operated from the ground directly at the base of a structure. 3. Isolation and tagging (no locks) is acceptable for an overhead distribution circuit under some of the following conditions: - ANSWER 1. The isolation point is a physical and visual like a line cut or riser removed. 2. The isolation point can only be operated by the operating authority or qualified worker. 3. The isolation point is protected from unauthorized access such as vertical height spacing. 4. Consider that a circuit has been isolated, tagged and grounded. workers returning the next day must: - ANSWER Visually check grounds to verify they are in good order, secure and test for voltage. 5. For lockout purposes, energy isolating devices shall be labelled or marked using a standardized nomenclature and format to indicate their function. Identification shall include: - ANSWER The equipment type, energy type, and magnitude. 6. Utilities often use a permitting system due to special circumstances of which conventional lockout is impracticable. The following is NOT a justified approach to this process: - ANSWER The isolation points are only simple single step actions. 7. A high voltage utility or electrical company is authorized to use Complex Lockout (tag permitting) under what regulatory condition: - ANSWER A variance application has been approved by the provincial authority. 8. Static created while fueling a commercial motor vehicle could be controlled by: - ANSWER Keeping the fuel nozzle in contact with the fuel spout of the vehicle. 9. When describing core leadership qualities, commanding respect and exhibiting respect for others are important qualities. Other important core qualities include: - ANSWER Capable of clear communication, trains effectively, gives feedback and follows up. 10. A truck driver maneuvers a corner and accelerates to posted speed, slows to accommodate traffic ahead, then accelerates again, keeping flow with traffic. Suddenly he hears a siren and sees an ambulance approaching from behind; he touches the brake, looks for a clear space, signals and moves right to allow the emergency vehicle to pass. In correct order, which two decision making modes has the driver demonstrated? - ANSWER Skill-based and rule-based 11. Hazard controls are measured, audited and evaluated: - ANSWER To ensure that the control methods designed for the hazard are appropriate and effective. 12. T/F: Bonding can be defined as the physical act of electrically connecting two or more pieces of equipment together to ensure they are as close as possible to the same electrical potential. - ANSWER True 13. In rural areas, the neutral is grounded much less frequently. As a result, the neutral may often be at potential ____ than that of ground. - ANSWER Higher 14. T/F: An isolated (de-energized) line can accidentally be re-energized from equipment failure, human error, induction and a lightning strike. - ANSWER True 15. T/F: Wood poles have varying levels of resistance depending on such factors as age, moisture, and wood preservatives. - ANSWER True 16. T/F: Grounding jumpers should be sized according to the maximum available fault current at the point of grounding. - ANSWER True 17. T/F: Except for a running ground, all grounds shall be installed using a live line tool (hot stick). - ANSWER True 18. T/F: You should always jumper the side phases to the center phase. You should never jumper an outside phase to the other outside phase. - ANSWER True 19. If you are a ground rod, install it as ___ ___ the work area as possible, preferably away from the roadside. - ANSWER Close to. 20. In the event of a fault connection, large electrical ground gradients can be generated around the ground rod. These in turn can result in dangerous _____ potentials. - ANSWER Step 21. T/F: In a substation, all non-energized substation components are electrically bonded to a mat beneath the substation. - ANSWER True 22. T/F: In a proper conductor stringing setup, the conductor, the equipment, and the ground gradient mat are electrically connected so they can be as close as possible to the same potential - ANSWER True 23. T/F: When stringing conductors, there must be a running ground installed on each conductor and sub-conductor. - ANSWER True 24. T/F: Before installing ground clamps on a conductor or buss, the conductor or buss and the clamp must be cleaned using a wire brush. - ANSWER True 25. When installing a grounding cluster bracket, the cluster bracket should be installed as ___________ the line workers feet as possible. - ANSWER Close to 26. When installing grounds, the ground end connection must be installed __________ using a live line tool. - ANSWER First 27. When removing grounds, the ground end connection must be removed _________ using a live line tool. - ANSWER Last 28. T/F: Grounds, when installed should be as short and straight as possible. Ground cables should never be coiled because of the act of coiling the ground can lower the cables ability to conduct current. - ANSWER True 29. single bolt, parallel groove connector - ANSWER a type of mechanical connector that consists of a single threaded bold that fits through two plates 30. Which of the following is usually not the generating voltage? A. 11 kV B. 13.2 kV C. 9.9 kV D. 6.6 kV - ANSWER C. 9.9 kV 31. The fact that a conductor carries more current on the surface as compared to core is known as A. corona B. permeability C. unsymmetrical fault D. skin effect - ANSWER D. skin effect 32. Transmission efficiency increases as A. voltage and power factor both decreases B. voltage and power factor both increase C. voltage increases but power factor decreases D. voltage decreases but power factor increases - ANSWER B. voltage and power factor both increase 33. Skin effect is proportional to A. (diameter of conductor)² B. diameter of conductor C. (diameter of conductor)³ D. (diameter of conductor)¹/² - ANSWER A. (diameter of conductor)² 34. The surge impedance for overhead line is taken as A. 50-60 ohms B. ohms C. 10-20 ohms D. 100-200 ohms - ANSWER D. 100-200 ohms 35. The effect of corona is A. increased reactance B. increased inductance C. increased energy loss D. all of the above - ANSWER C. increased energy loss 36. The current drawn by the line due to corona losses is A. non-sinusoidal B. sinusoidal C. square D. triangular - ANSWER A. non-sinusoidal 37. Presence of ozone as a result of corona is harmful because A. it gives bad odor B. it transfers energy to the ground C. reduces the power factor D. it corrodes the material - ANSWER D. it corrodes the material 38. For 66 kV lines, the number of insulator discs used is A. 8 B. 12 C. 5 D. 3 - ANSWER C. 5 39. Wooden poles for supporting transmission lines are used for voltages up to A. 22 kV B. 440 kV C. 11 kV D. 66 kV - ANSWER A. 22 kV 40. The surge impedance of transmission lines is about A. 100 ohms B. 250 ohms C. 500 ohms D. 50 ohms - ANSWER C. 500 ohms 41. For transmission lines, the standing wave ration is the ratio of A. maximum current to minimum voltage B. maximum voltage to minimum voltage C. maximum reactance to minimum reactance D. peak voltage to rms voltage - ANSWER B. maximum voltage to minimum voltage 42. For distortionless transmission line (G = shunt conductance between two wires) A. RL = GC B. RG = LC C. RLGC = 0 D. R/L = G/C - ANSWER D. R/L = G/C 43. A relay used in long transmission line is A. reactance relay B. impedance relay C. mho's relay D. no relay is used - ANSWER C. mho's relay 44. The power transmitted will be maximum when A. sending end voltage is more B. receiving end voltage is more C. reactance is high D. corona losses are least - ANSWER A. sending end voltage is more 45. Surge impedance of transmission line is given by A. √C/L B. √CL C. 1/√CL D. √L/C - ANSWER D. √L/C 46. Stages impedance of transmission line is given by A. generation and transmission B. generation, distribution and transmission C. generation, dissipation and distribution D. generation, transmission and distribution - ANSWER D. generation, transmission and distribution 47. The purpose of a grid system is to A. interconnect the power stations B. supply energy to remote areas C. make extra high voltage available to consumers D. make distribution of energy at reasonable cost - ANSWER A. interconnect the power stations

Content preview

CUSP - T&D EXAM STUDY GUIDE
2025/2026 COMPLETE QUESTIONS BANK
AND CORRECT DETAILED ANSWERS WITH
RATIONALES || 100% GUARANTEED PASS
<BRAND NEW VERSION>




1. As per CAN/ULC S801, on an electrical distribution overhead utility line
circuit, verification of voltage absence can be achieved by: - ANSWER ✓
Using an approved voltage detector.

2. Isolation and tagging (no locks) is acceptable on an overhead distribution
circuit under some of the following conditions, EXCEPT for: - ANSWER ✓
The isolation can be operated from the ground directly at the base of a
structure.

3. Isolation and tagging (no locks) is acceptable for an overhead distribution
circuit under some of the following conditions: - ANSWER ✓ 1. The
isolation point is a physical and visual like a line cut or riser removed.
2. The isolation point can only be operated by the operating authority or
qualified worker.
3. The isolation point is protected from unauthorized access such as vertical
height spacing.

4. Consider that a circuit has been isolated, tagged and grounded. workers
returning the next day must: - ANSWER ✓ Visually check grounds to verify
they are in good order, secure and test for voltage.

5. For lockout purposes, energy isolating devices shall be labelled or marked
using a standardized nomenclature and format to indicate their function.

, Identification shall include: - ANSWER ✓ The equipment type, energy type,
and magnitude.

6. Utilities often use a permitting system due to special circumstances of which
conventional lockout is impracticable. The following is NOT a justified
approach to this process: - ANSWER ✓ The isolation points are only simple
single step actions.

7. A high voltage utility or electrical company is authorized to use Complex
Lockout (tag permitting) under what regulatory condition: - ANSWER ✓ A
variance application has been approved by the provincial authority.

8. Static created while fueling a commercial motor vehicle could be controlled
by: - ANSWER ✓ Keeping the fuel nozzle in contact with the fuel spout of
the vehicle.

9. When describing core leadership qualities, commanding respect and
exhibiting respect for others are important qualities. Other important core
qualities include: - ANSWER ✓ Capable of clear communication, trains
effectively, gives feedback and follows up.

10.A truck driver maneuvers a corner and accelerates to posted speed, slows to
accommodate traffic ahead, then accelerates again, keeping flow with traffic.
Suddenly he hears a siren and sees an ambulance approaching from behind;
he touches the brake, looks for a clear space, signals and moves right to
allow the emergency vehicle to pass. In correct order, which two decision-
making modes has the driver demonstrated? - ANSWER ✓ Skill-based and
rule-based

11.Hazard controls are measured, audited and evaluated: - ANSWER ✓ To
ensure that the control methods designed for the hazard are appropriate and
effective.

12.T/F: Bonding can be defined as the physical act of electrically connecting
two or more pieces of equipment together to ensure they are as close as
possible to the same electrical potential. - ANSWER ✓ True

,13.In rural areas, the neutral is grounded much less frequently. As a result, the
neutral may often be at potential ____ than that of ground. - ANSWER ✓
Higher

14.T/F: An isolated (de-energized) line can accidentally be re-energized from
equipment failure, human error, induction and a lightning strike. - ANSWER
✓ True

15.T/F: Wood poles have varying levels of resistance depending on such factors
as age, moisture, and wood preservatives. - ANSWER ✓ True

16.T/F: Grounding jumpers should be sized according to the maximum
available fault current at the point of grounding. - ANSWER ✓ True

17.T/F: Except for a running ground, all grounds shall be installed using a live
line tool (hot stick). - ANSWER ✓ True

18.T/F: You should always jumper the side phases to the center phase. You
should never jumper an outside phase to the other outside phase. - ANSWER
✓ True

19.If you are a ground rod, install it as ___ ___ the work area as possible,
preferably away from the roadside. - ANSWER ✓ Close to.

20.In the event of a fault connection, large electrical ground gradients can be
generated around the ground rod. These in turn can result in dangerous
_____ potentials. - ANSWER ✓ Step

21.T/F: In a substation, all non-energized substation components are electrically
bonded to a mat beneath the substation. - ANSWER ✓ True

22.T/F: In a proper conductor stringing setup, the conductor, the equipment,
and the ground gradient mat are electrically connected so they can be as
close as possible to the same potential> - ANSWER ✓ True

23.T/F: When stringing conductors, there must be a running ground installed on
each conductor and sub-conductor. - ANSWER ✓ True

, 24.T/F: Before installing ground clamps on a conductor or buss, the conductor
or buss and the clamp must be cleaned using a wire brush. - ANSWER ✓
True

25.When installing a grounding cluster bracket, the cluster bracket should be
installed as ___________ the line workers feet as possible. - ANSWER ✓
Close to

26.When installing grounds, the ground end connection must be installed
__________ using a live line tool. - ANSWER ✓ First

27.When removing grounds, the ground end connection must be removed
_________ using a live line tool. - ANSWER ✓ Last

28.T/F: Grounds, when installed should be as short and straight as possible.
Ground cables should never be coiled because of the act of coiling the
ground can lower the cables ability to conduct current. - ANSWER ✓ True

29.single bolt, parallel groove connector - ANSWER ✓ a type of mechanical
connector that consists of a single threaded bold that fits through two plates

30.Which of the following is usually not the generating voltage?

A. 11 kV
B. 13.2 kV
C. 9.9 kV
D. 6.6 kV - ANSWER ✓ C. 9.9 kV

31.The fact that a conductor carries more current on the surface as compared to
core is known as

A. corona
B. permeability
C. unsymmetrical fault
D. skin effect - ANSWER ✓ D. skin effect

32.Transmission efficiency increases as

Document information

Uploaded on
July 26, 2025
Number of pages
43
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49
Purchased by 13 students

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProfBenjamin
3.7
(152)
Sold
766
Followers
18
Items
4018
Last sold
5 hours ago

Reviews from verified buyers

4 months ago

Thank you for your great feedback! Wishing you the best in your studies. If you ever need support with exam prep, assignments, research, test banks, or study resources, feel free to reach out or check out my page. I'm here to help! Warm regards

5 months ago

Thank you for your great feedback! Wishing you the best in your studies. If you ever need support with exam prep, assignments, research, test banks, or study resources, feel free to reach out or check out my page. I'm here to help! Warm regards

5 months ago

Thank you for your great feedback! Wishing you the best in your studies. If you ever need support with exam prep, assignments, research, test banks, or study resources, feel free to reach out or check out my page. I'm here to help! Warm regards

8 months ago

Thank you for your great feedback! Wishing you the best in your studies. If you ever need support with exam prep, assignments, research, test banks, or study resources, feel free to reach out or check out my page. I'm here to help! Warm regards




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions