1|Page
Texas TCEQ Installer II Practice Exam
2025; Comprehensive Q&A For Certification
Success
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures (sewer pipes)from driveways and sidewalks - correct-
answer-may run underneath if SCH 80 or sleeved
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures (sewer pipes)from surface improvements - correct-answer-
may run up to it as long as it is SCH 80 or sleeved
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures (sewer pipes)from secondary effluent pipes - correct-
answer-has no setbacks from building foundations
,2|Page
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures from surface application(edge of spray area) - correct-
answer-No seperation except property lines(20) and swimming pools(25)
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures from drip irrigation - correct-answer-No seperation distances
except property lines (5) feet
Underground Easements from tanks - correct-answer-1 foot
Underground Easements from soil absorption systems & unlined ET beds - correct-
answer-1 foot
Underground Easements from lined evaptranspiration beds - correct-answer-1
foot
Underground Easements from sewer pipes with watertight joints - correct-
answer-1 foot
, 3|Page
Underground Easements from surface application (Edge of spray area) - correct-
answer-May spray to edge of easement but not into sprinkler heads must be 1
foot from easement edge
Underground Easements from drip irrigation - correct-answer-1 foot
Overhead easements from tanks - correct-answer-1 foot unless permission has
been granted then none
Overhead easements from soil absorption systems & unlined beds - correct-
answer-1 foot unless permission has been granted then none
Overhead easements from lined ET beds - correct-answer-1 foot unless
permission has been granted
Overhead easements from sewer pipes with watertight joints - correct-answer-1
foot unless permission has been granted
Texas TCEQ Installer II Practice Exam
2025; Comprehensive Q&A For Certification
Success
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures (sewer pipes)from driveways and sidewalks - correct-
answer-may run underneath if SCH 80 or sleeved
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures (sewer pipes)from surface improvements - correct-answer-
may run up to it as long as it is SCH 80 or sleeved
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures (sewer pipes)from secondary effluent pipes - correct-
answer-has no setbacks from building foundations
,2|Page
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures from surface application(edge of spray area) - correct-
answer-No seperation except property lines(20) and swimming pools(25)
Foundations, Buildings, Surface Improvements,Property Lines, Swimming Pools
and Other structures from drip irrigation - correct-answer-No seperation distances
except property lines (5) feet
Underground Easements from tanks - correct-answer-1 foot
Underground Easements from soil absorption systems & unlined ET beds - correct-
answer-1 foot
Underground Easements from lined evaptranspiration beds - correct-answer-1
foot
Underground Easements from sewer pipes with watertight joints - correct-
answer-1 foot
, 3|Page
Underground Easements from surface application (Edge of spray area) - correct-
answer-May spray to edge of easement but not into sprinkler heads must be 1
foot from easement edge
Underground Easements from drip irrigation - correct-answer-1 foot
Overhead easements from tanks - correct-answer-1 foot unless permission has
been granted then none
Overhead easements from soil absorption systems & unlined beds - correct-
answer-1 foot unless permission has been granted then none
Overhead easements from lined ET beds - correct-answer-1 foot unless
permission has been granted
Overhead easements from sewer pipes with watertight joints - correct-answer-1
foot unless permission has been granted