RCDD 12th Edition Chapter 9 Exam Questions and Answers Fully Solved Standard for installation of lighting protection systems = - Answers NFPA 780 Primary responsibility of the ITS designer is safeguarding = - Answers Personal, property, and equipment from foreign electrical voltages and currents The results of such disturbances could be = - Answers - Death or injury due to electrical shock - Destruction of electronic equip. and property due to electrical fire - Component malfunction or degradation - Work or process disruption ITS designer must consider = - Answers - Lighting - Ground potential rise - Contact with electrical power circuits - Electromagnetic interface (EMI) - Radio frequency interface (RFI) - Electromagnetic compatibility (EMC) ITS designers are not responsible for = - Answers Engineering the portions of the electrical system related to alternating current(AC) electrical ground faults, air terminal lighting protection systems, or transient voltage surge protection Best time to design a grounding protection scheme = - Answers Initial planning and construction Bonding = - Answers Two metallic items ITS designer is typically responsible for = - Answers Telecomm bonding and grounding and the telecommunications circuit protectors The ITS designer must recognize that three separate and distinct grounding systems should be in place at every site = - Answers - AC grounding electrode system - Equipment grounding system - Telecomm bonding infrastructure ITS designer has no authority over = - Answers The AC grounding electrode system The purpose of the AC grounding electrode system(earthing system) is to = - Answers - Establish a zero volt reference for AC electrical power systems, whether utility provided or customer derived - Provide a path for the dissipation of currents due to lighting or accidental contact with higher voltage systems - Provide a path for the dissipation of electrostatic discharge currents The AC grounding system does not provide adequate electrical protection for = - Answers People and equipment in the event of an electrical fault The AC grounding electrode system consist of two main components = - Answers - Grounding electrode conductor [GEC] - Grounding electrode If building steel is used a grounding electrode = - Answers ITS designer must specify that the

Show more Read less
Institution
RCDD
Course
RCDD









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
RCDD
Course
RCDD

Document information

Uploaded on
July 19, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

RCDD 12th Edition Chapter 9 Exam Questions and Answers Fully Solved

Standard for installation of lighting protection systems = - Answers NFPA 780

Primary responsibility of the ITS designer is safeguarding = - Answers Personal, property, and equipment
from foreign electrical voltages and currents

The results of such disturbances could be = - Answers - Death or injury due to electrical shock

- Destruction of electronic equip. and property due to electrical fire

- Component malfunction or degradation

- Work or process disruption

ITS designer must consider = - Answers - Lighting

- Ground potential rise

- Contact with electrical power circuits

- Electromagnetic interface (EMI)

- Radio frequency interface (RFI)

- Electromagnetic compatibility (EMC)

ITS designers are not responsible for = - Answers Engineering the portions of the electrical system
related to alternating current(AC) electrical ground faults, air terminal lighting protection systems, or
transient voltage surge protection

Best time to design a grounding protection scheme = - Answers Initial planning and construction

Bonding = - Answers Two metallic items

ITS designer is typically responsible for = - Answers Telecomm bonding and grounding and the
telecommunications circuit protectors

The ITS designer must recognize that three separate and distinct grounding systems should be in place
at every site = - Answers - AC grounding electrode system

- Equipment grounding system

- Telecomm bonding infrastructure

ITS designer has no authority over = - Answers The AC grounding electrode system

The purpose of the AC grounding electrode system(earthing system) is to = - Answers - Establish a zero
volt reference for AC electrical power systems, whether utility provided or customer derived

, - Provide a path for the dissipation of currents due to lighting or accidental contact with higher voltage
systems

- Provide a path for the dissipation of electrostatic discharge currents

The AC grounding system does not provide adequate electrical protection for = - Answers People and
equipment in the event of an electrical fault

The AC grounding electrode system consist of two main components = - Answers - Grounding electrode
conductor [GEC]

- Grounding electrode

If building steel is used a grounding electrode = - Answers ITS designer must specify that the telecomm
busbar be installed on or near a structural steel member within the TR or EF

In new construction the electrical contractor must = - Answers Provide means of access

Telecommunications personnel should not move, modify or disconnect any ground electrode conductor
without = - Answers The direct participant of a qualified electrical maintenance person

If metallic water pipes are used for grounding (earthing) = - Answers They should never be a single
ground (earth) source

The recommended max AC current value on any bonding conductor should be less than = - Answers 1
amp

The recommended max DC current values should be less than = - Answers 500 milliamperes

Two point bonding measurements = - Answers Earth ground tester

Two point bonding measurements is preformed using an earth grounding resistance tester that is
configured for? - Answers Continuity test

Maximum value for the bonding resistance between these two points is? - Answers 0.1 ohms (100
milliohms)

How do you measure grounding impedance = - Answers Ground impedance tester

The equipment grounding system impedance is dependent on a number of physical characteristics
including the = - Answers - Tightness of the equipment grounding conductor terminations

- Length of the equipment grounding conductor

-Number of bends in the equipment ground conductor path

- Size (diameter) of the equipment ground conductor

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
337
Member since
1 year
Number of followers
16
Documents
28501
Last sold
3 hours ago
Tutor Joshua

Here You will find all Documents and Package Deals Offered By Tutor Joshua.

3.6

53 reviews

5
18
4
14
3
12
2
0
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions