7/13/25, 1:26 PM ACI Concrete Field Testing Technician- Grade I Exam EXAM Questions and Answers (A+ Solution guide) (2025) Questions And An…
ACI Concrete Field Testing Technician- Grade I
Exam EXAM Questions and Answers (A+ Solution
guide) (2025) Questions And Answers Solved
100% Correct!!
Save
Practice questions for this set
Learn 2 /7 Study with Learn
The temperature of concrete may be measured in a wheelbarrow. True or
False?
Give this one a try later!
True 2 False
Press any key to
Don't know?Continue
continue
Terms in this set (141)
https://quizlet.com/1059980330/aci-concrete-field-testing-technician-grade-i-exam-exam-questions-and-answers-a-solution-guide-2025-questions-an… 1/22
,7/13/25, 1:26 PM ACI Concrete Field Testing Technician- Grade I Exam EXAM Questions and Answers (A+ Solution guide) (2025) Questions And An…
The sensor of the 3 in. [75 mm]
temperature measuring
device shall be
submerged a minimum of
_____ in. [_____mm] into the
freshly mixed concrete.
The temperature 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C]
measuring device shall
have a capacity of
measuring temperature of
freshly mixed concrete to
+- _____ degrees F [+- _____ C]
throughout a range of _____.
The temperature Annually, accuracy
measuring device shall be
calibrated _____, or
whenever there is a
question of _____.
The temperature of True
concrete may be
measured in a
wheelbarrow. True or
False?
The temperature of True
concrete may be
measured in a wall form.
True of False
A composite sample of False
concrete is required even
if the only purpose for
obtaining the sample is to
determine temperature.
True of False?
https://quizlet.com/1059980330/aci-concrete-field-testing-technician-grade-i-exam-exam-questions-and-answers-a-solution-guide-2025-questions-an… 2/22
, 7/13/25, 1:26 PM ACI Concrete Field Testing Technician- Grade I Exam EXAM Questions and Answers (A+ Solution guide) (2025) Questions And An…
What must be done to the Dampen (with water)
sample container prior to
sampling the concrete?
What must be done to the Gently press the concrete around the temperature
concrete surrounding the measuring device at the surface of the concrete
temperature measuring
device after the device is
submerged in the fresh
concrete.
How long must the At least 2 minutes but not more than 5 minutes
temperature measuring
device remain in the
freshly mixed concrete?
After the temperature of Reporting of temperature
the concrete is read, what
is required?
The temperature of 1 degree F [0.5 C]
concrete is reported to
the nearest _____ degrees F
[_____ C]
According to ASTM Verify conformance to a specified requirement for
C1064, what is one reason temperature of concrete
to take the temperature of
concrete?
A maximum temperature False
of freshly mixed concrete
is specified in ASTM
C1064. True of False?
The sample of concrete False
used for temperature
determination must be
rodded 25 times. True or
False?
https://quizlet.com/1059980330/aci-concrete-field-testing-technician-grade-i-exam-exam-questions-and-answers-a-solution-guide-2025-questions-an… 3/22
ACI Concrete Field Testing Technician- Grade I
Exam EXAM Questions and Answers (A+ Solution
guide) (2025) Questions And Answers Solved
100% Correct!!
Save
Practice questions for this set
Learn 2 /7 Study with Learn
The temperature of concrete may be measured in a wheelbarrow. True or
False?
Give this one a try later!
True 2 False
Press any key to
Don't know?Continue
continue
Terms in this set (141)
https://quizlet.com/1059980330/aci-concrete-field-testing-technician-grade-i-exam-exam-questions-and-answers-a-solution-guide-2025-questions-an… 1/22
,7/13/25, 1:26 PM ACI Concrete Field Testing Technician- Grade I Exam EXAM Questions and Answers (A+ Solution guide) (2025) Questions And An…
The sensor of the 3 in. [75 mm]
temperature measuring
device shall be
submerged a minimum of
_____ in. [_____mm] into the
freshly mixed concrete.
The temperature 1 degree F [0.5 C], 30 degrees F to 120 F [0 C to 50 C]
measuring device shall
have a capacity of
measuring temperature of
freshly mixed concrete to
+- _____ degrees F [+- _____ C]
throughout a range of _____.
The temperature Annually, accuracy
measuring device shall be
calibrated _____, or
whenever there is a
question of _____.
The temperature of True
concrete may be
measured in a
wheelbarrow. True or
False?
The temperature of True
concrete may be
measured in a wall form.
True of False
A composite sample of False
concrete is required even
if the only purpose for
obtaining the sample is to
determine temperature.
True of False?
https://quizlet.com/1059980330/aci-concrete-field-testing-technician-grade-i-exam-exam-questions-and-answers-a-solution-guide-2025-questions-an… 2/22
, 7/13/25, 1:26 PM ACI Concrete Field Testing Technician- Grade I Exam EXAM Questions and Answers (A+ Solution guide) (2025) Questions And An…
What must be done to the Dampen (with water)
sample container prior to
sampling the concrete?
What must be done to the Gently press the concrete around the temperature
concrete surrounding the measuring device at the surface of the concrete
temperature measuring
device after the device is
submerged in the fresh
concrete.
How long must the At least 2 minutes but not more than 5 minutes
temperature measuring
device remain in the
freshly mixed concrete?
After the temperature of Reporting of temperature
the concrete is read, what
is required?
The temperature of 1 degree F [0.5 C]
concrete is reported to
the nearest _____ degrees F
[_____ C]
According to ASTM Verify conformance to a specified requirement for
C1064, what is one reason temperature of concrete
to take the temperature of
concrete?
A maximum temperature False
of freshly mixed concrete
is specified in ASTM
C1064. True of False?
The sample of concrete False
used for temperature
determination must be
rodded 25 times. True or
False?
https://quizlet.com/1059980330/aci-concrete-field-testing-technician-grade-i-exam-exam-questions-and-answers-a-solution-guide-2025-questions-an… 3/22