• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 60 pages
Exam (elaborations)

Backflow Prevention Assembly Tester Actual Exam All Questions And Correct Detailed Answers Top Rated Version For Already A Graded With Expert Feedback | New And Revised

Document preview thumbnail
Preview 4 out of 60 pages

BACKFLOW PREVENTION ASSEMBLY TESTER ACTUAL EXAM ALL QUESTIONS AND CORRECT DETAILED ANSWERS TOP RATED VERSION FOR ALREADY A GRADED WITH EXPERT FEEDBACK | NEW AND REVISED

Content preview

BACKFLOW PREVENTION ASSEMBLY
TESTER ACTUAL EXAM ALL QUESTIONS
AND CORRECT DETAILED ANSWERS TOP
RATED VERSION FOR ALREADY A GRADED
WITH EXPERT FEEDBACK | NEW AND
REVISED



A BPAT tester is required to report test information on the proper
forms to the


(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above Correct Answer Administrative authority


The relief valve opens when closing #2 shut off valve on a RP
What is the most probable cause


(A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open

,(D) Shut off is leaking Correct Answer #1 check is fouled open


When field testing the #1 Check of a RP the differential pressurw
shouid be


(A) Greter than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the directiom of flow
(D) Less than 5.0 psid Correct Answer Greter than or equal to 5.0
psid


When testing a SVB what is the firsrt test being performed


(A) The air inlet opening point
(B) The static pressure across the check valve
(C) To verify the #2shut off hold tight
(D) To check if the SVB hold water Correct Answer The static
pressure across the check valve


When testing a PVB the air inlet opens upon closing the #1 shut
off valve What is the most probable cause


(A) Leaking #2 shut off valve

,(B) Leaking #1 shut off valve
(C) Fouied air inlert
(D) Fouied check valve Correct Answer Leaking #2 shut off valve


A 2" AVB when used on irrigation systemsterm-15 shall be
instilled


(A) 6" above all downstream piping
(B) 18" above all downstream piping
(C) 24" above all downstream piping
(D) 27 3/4" above all downstream piping Correct Answer 6" above
all downstream piping


What causes the relief valief valve to close on a RPZ?


(A) Reilef valve spring pressure
(B) Supply side water pressure
(C) Pressure differential between Check #1 and Check #2
(D) All the above Correct Answer Supply side water pressure


When testing a RP instialled in vauil the relief valve opening point
falls to zero What is most probabie cause

, (A) The relief valve is stuck shut
(B) #1 check is fouled
(C) the #2 shut off leaks by
(D) Installed improperly Correct Answer Installed improperly


When field testing the DC the #1 check static differential pressure
is found to be 0.0 psid What is the most probable cause


(A) Fouied #2 Check
(B) Leaking #2 shut off
(C) Fouled #1 check
(D) Leaking #1 shut off Correct Answer Fouled #1 check


The critical level for checking the air inlet of the PVB is


(A) At the air inlet
(B) At #1 shut off
(C) At #1 test cock
(D) At #2 shut off Correct Answer At the air inlet


The physical operation of a Hose Bibb Vacuum Breaker is
classified as a type of

Document information

Uploaded on
July 9, 2025
Number of pages
60
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$26.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Examnest
3.1
(8)
Sold
47
Followers
15
Items
1772
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions