AND ANSWERS RATED A+
✔✔Generally, asbestos has abatement projects are - ✔✔Greater than 25 ft.² or 10
linear feet
If it falls below 25 ft.² of 10 feet is considered operations and maintenance
✔✔What should you always remember when working with asbestos? - ✔✔Always work
with it WET. You can apply to the D.E.P for certain exceptions to perform dry work.
✔✔Cleaning procedure with asbestos - ✔✔HEPA, wash, HEPA
Use Amended water
✔✔Who runs asbestos projects? - ✔✔Asbestos safety technicians
✔✔What pressure level must be kept in mind on worksites? - ✔✔If the negative
pressure drops to 0.1 the entire job can be stopped
✔✔How often should you do air changes? - ✔✔Every 15 minutes
✔✔Air monitoring results should not exceed - ✔✔24 hours for PCM
72 hours for TCM
✔✔Masks and protective factors - ✔✔Half face (protection factor equals 10)
Full face (protection factor equals 50)
PAPR (100)
SBAs (10,000)
✔✔How many rooms per decon - ✔✔Three
1. 30/equipment room.
2. Shower shower room.
3. Clean room
✔✔What is the micron filtration system for the water heater? - ✔✔1) 20
2) 5
✔✔What two things are needed for the Decon? - ✔✔Filtration system
Water heater
✔✔What are examples of miscellaneous items? - ✔✔Vinyl, ceiling tiles, TSI
, ✔✔Full breakdown of what's required for Decon rooms - ✔✔1. Three rooms.
2. 4 z flaps.
3. Poly inside and outside
✔✔What are the units within a deacon called? - ✔✔Airlocks
✔✔What are the pressure rules for projects? - ✔✔0.05 for occupied spaces (can't fall
below)
0.03 for unoccupied places (can't fall below)
0.01 Shut down
✔✔What two OSHA regulation codes must always be followed - ✔✔29 CFR 1910.1001
(General Industry)
AND
29 CFR 1926.1101 (Construction)
✔✔What part of the NESHAP regulation should also be considered? - ✔✔40 CFR Part
61, S
✔✔NJ Radiation Protection Programs, including protocols for asbestos handling and
removal - ✔✔N.J.A.C 7:28-60
✔✔Ladders and rules pertaining to usage - ✔✔- For every 4 feet up, 1 foot out
- Labels must be clear and undamaged
- Commonly used for testing purposes: Step and Extension ladders
✔✔Scaffolding and rules pertaining to usage - ✔✔- 4 to 1 ratio
- Lanyards, horizontal and vertical protection, body harness
- Top rail height: 42 inches
- Bottom rail height: 21 inches
- Toe board: 3 1/2 inches
- Must always be at least 10 ft away from power lines or source
- Must be 10 ft or higher than building
✔✔What is the max numbers to keep in mind for top rail, bottom, and toe board when
using scaffoldings? - ✔✔Top Rail: 42 inches
Bottom: 21 Inches
Toe Board: 3 1/2