Content preview

Mike Holt Chapter 3 Study Guide with
Complete Solutions
100 - ANSWER-Handhole enclosure covers shall require the use of tools to open, or
they shall weigh over ___ lb.

14 - ANSWER-The minimum size copper conductor permitted for branch circuits under
600V is ___ AWG.

2 - ANSWER-For one-family dwellings and the individual dwelling units of two-family
and multifamily dwellings, single-phase feeder conductors consisting of ___ ungrounded
conductor(s) and the neutral conductor from a 208Y/120 volt system shall be permitted
to be sized in accordance with 310.15(B)(7)(1) through (3).

60 - ANSWER-If cables meeting the requirements in 310.15(B)(3)(4)a through C with
more than 20 current-carrying conductors are installed longer than 24 in. without
maintaining spacing, are stacked, or are supported on bridle rings, a ___ percent
adjustment factor shall be applied.

60 degrees Celsius - ANSWER-Type AC cable installed in thermal insulation shall have
conductors that are rated at 90 degrees Celsius. The ampacity of the cable in this
application shall not exceed that of a ___ rated conductor.

Aluminum - ANSWER-___ is a nonferrous, nonmagnetic metal that has no heating due
to hysteresis heating.

Angle - ANSWER-In an FMC installation, ___ connectors shall not be concealed.

approved - ANSWER-IMC, elbows, couplings, and fittings shall be permitted to be
installed in concrete, in direct contact with the earth, or in areas subject to severe
corrosive influences where protected by corrosion protection ___ for the condition.

at intervals not exceeding 4 1/2 ft - ANSWER-FMC shall be supported and secured ___.

be listed and identified for such use - ANSWER-Type MC cable shall be listed and
fittings used for connecting Type MC cable to boxes, cabinets, or other equipment shall
___.

C. A and B - ANSWER-At type AC cable terminations, a(n) ___ shall be provided.
A. fitting (or box design) that protects the conductors from abrasion
B. insulating bushing between the conductors and the cable armor
C. A and B
D. none of these

, C. A and B - ANSWER-Wiring methods and cabling systems, listed for use in other
spaces used for environmental air (plenums), shall be permitted to be installed in ducts
specifically fabricated for environmental air-handling purposes.
A. only if necessary to connect to equipment or devices associated with the direct action
upon or sensing of the contained air
B. if the total length of such wiring methods of cabling systems does not exceed 4 ft
C. A and B
D. none of these

C. A or B - ANSWER-Metal wireways are sheet metal troughs with ___ for housing and
protecting electric conductors and cable.
A. removable covers
B. hinged covers
C. a or b
D. none of these

combustible - ANSWER-in walls constructed of wood or other ___ material, electrical
cabinets shall be flush with the finished surface or project therefrom.

corrosion protection - ANSWER-Galvanized steel, stainless steel, and red brass RMC
elbows, couplings, and fittings shall be permitted to be installed in concrete, in direct
contact with the earth, or in areas subject to severe corrosive influences when protected
by ___ approved for the condition.

couplings - ANSWER-Running threads shall not be used on RMC for connections at
___.

D. A and B - ANSWER-Cable trays shall be ___ except as permitted by 392.18(D).
A. exposed
B. accessible
C. concealed
D. A and B

D. A or B - ANSWER-All conductors of the same circuit shall be ___, unless otherwise
specifically permitted in the Code.
A. in the same raceway or cable
B. in close proximity in the same trench
C. the same size
D. A or B

D. A or B - ANSWER-Aluminum raceways, cable trays, cablebus, auxiliary gutters,
cable armor, boxes, able sheathing, cabinets, elbows, couplings, nipples, fittings,
supports, and support hardware ___ shall be provided with supplementary corrosion
protection.
A. embedded or encased in concrete
B. in direct contact with the earth

Document information

Uploaded on
July 3, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LUCKYSTAR2022
3.5
(163)
Sold
931
Followers
726
Items
9664
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions